Advanced Technology Services - Caterpillar Technical Center

14009 Old Galena Rd, Tech Center TCL, 61523, Chillicothe, IL, United States

Visit website
A2LA 1592.05ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
22
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 22 scope lines.

A2LA certificate 1592.05 · 22 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017-0.01 to 100 %
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1592.05) Revised 11/03/2025 Page 2 of 21 II. Dimensional Testing/Calibration Parameter/Equipment Range CMC2, 4 (±) Comments Surface Analysis6 Ra: Up to 260 mm Ra: Up to 100 mm 2.2 µm 0.31 µm Mahr LD-260 Zeiss Surfcom 2000 Differential Transducers 6 (LVDT) Up to 50.8 mm (50.9 to 177.8) mm (177.9 to 304.8) mm 0.17 µm/mm + 6.4 µm 0.069 % 0.061 % Mitutoyo 197-201 micrometer head w/ Agilent 34410A Starrett 656-7041 dial indicator Starrett 656-12041 dial indicator Inside Diameter6 (54 to 79.5) mm (78.5 to 156) mm (152.5 to 308) mm 4.3 µm 5.7 µm 7.0 µm Dial bore #4 gage Dial bore #5 gage Dial bore #6 gage Length 6 – 1D Up to 25.4 mm Up to 127 mm Up to 1000 mm Up to 4000 mm 4.0 µm 0.17 mm 36 µm 0.14 mm Digital indicator Chatillon test stand Mahr 817 CLM height AACCM 8540-6 Length 6 – 2D X-Axis: Up to 152.4 mm Y-Axis: Up to 127 mm X-Axis: Up to 180 mm Y-Axis: Up to 127 mm 7.8 µm 7.9 µm Dynascope microscope Dynascope microscope w/ multi lens External Diameter 6 Up to 25 mm (25 to 50) mm (50 to 75) mm (75 to 100) mm (100 to 125) mm (125 to 150) mm (0.1 to 101.6) mm 2.4 µm 2.6 µm 3.1 µm 3.5 µm 5.2 µm 6.3 µm 3.1 µm Mitutoyo micrometer Starrett 733 micrometer Laser micrometer
to 260 mm
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1592.05) Revised 11/03/2025 Page 3 of 21 III. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 5 (±) Comments DC Voltage – Generate (0 to 220) mV (0.22 to 2.2) V (2.2 to 11) V (11 to 22) V (22 to 220) V (220 to 1100) V (1000 to 5000) V 8.9 µV/V + 0.40 µV 5.2 µV/V + 0.7 µV 3.8 µV/V + 2.5 µV 7.4 µV/V + 4.0 µV 5.2 µV/V + 40 µV 6.8 µV/V + 0.40 mV 1.7 mV/V + 2.6 V Fluke 5730A SRS-PS350 DC Voltage – Measure (0 to 200) mV (0.2 to 2) V (2 to 20) V (20 to 200) V (200 to 1000) V 6.1 µV/V + 0.10 µV 3.7 µV/V + 0.40 µV 3.7 µV/V + 4.0 µV 5.7 µV/V + 40 µV 5.7 µV/V + 0.53 mV Fluke 8508A DC Current – Generate (0 to 220) µA (0.22 to 2.2) mA (2.2 to 22) mA (22 to 220) mA (0.22 to 2.2) A (2.2 to 11) A (11 to 20.5) A (0 to 2) A (2 to 20) A (20 to 120) A (120 to 2500) A (100 to 1000) A (1000 to 2000) A 45 µA/A + 6.0 nA 38 µA/A + 7.0 nA 38 µA/A + 40 nA 47 µA/A + 0.70 µA 95 µA/A + 12 µA 3.6 mA/A + 0.48 mA 1.3 mA/A + 0.75 mA 0.76 mA/A + 0.080 mA 0.057 mA/A + 0.80 mA 93 µA/A + 4.8 mA 2.1 mA/A + 0.84 A 0.42 A 0.85 A Fluke 5730A Fluke 5730A & Fluke 5725A Fluke 5522A Fluke 52120A / coil Current amplifier w/ transducers DC Current – Measure (10 to 200) µA (0.2 to 2) mA (2 to 20) mA (20 to 200) mA (0.2 to 2) A (2 to 20) A 13 µA/A + 0.40 nA 15 µA/A + 4.0 nA 17 µA/A + 40 nA 57 µA/A + 0.80 µA 0.21 mA/A + 16 µA 0.45 mA/A + 0.40 mA Fluke 8508A
4--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1592.05) Revised 11/03/2025 Page 4 of 21 Parameter/Equipment Range CMC2, 5 (±) Comments Electrical Charge (In Coulomb) – Measure (0 to 200) nC 2.8 pC/nC + 0.5 nC Keithley 6514 Capacitance – Generate (0.4 to 1.0999) nF (1.1 to 3.2999) nF (3.3 to 10.9999) nF (11 to 32.9999) nF (33 to 109.999) nF (110 to 329.999) nF (0.33 to 1.099 99) µF (1.1 to 3.2999) µF (3.3 to 10.9999) µF (11 to 32.9999) µF (33 to 109.999) µF (110 to 329.999) µF (0.33 to 1.0999) mF (1.1 to 3.2999) mF (3.3 to 10.999) mF (11 to 32.999) mF (33 to 109.999) mF 14 pF/nF + 5.6 pF 6.1 pF/nF + 3.3 pF 2.5 pF/nF + 1.6 pF 1.5 pF/nF + 83 pF 2.7 pF/nF + 11 pF 4.7 pF/nF + 0.22 nF 2.6 nF/µF + 0.15 nF 4.9 nF/µF + 2.4 nF 3 nF/µF + 9 nF 6.9 nF/µF + 46 nF 5.3 nF/µF + 58 nF 6.6 nF/µF + 0.42 µF 4.9 nF/µF + 2.4 nF 6.8 µF/mF + 4.5 µF 5.3 µF/mF + 7.5 µF 9.9 µF/mF + 79 µF 16 µF/mF + 0.52 mF Fluke 5522A Parameter/Range Frequency CMC2, 5 (±) Comments AC Voltage – Generate (0 to 2.2) mV (2.2 to 22) mV (22 to 220) mV (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz 0.3 µV/mV + 5.0 µV 0.12 µV/mV + 5.0 µV 0.1 µV/mV + 5.0 µV 0.25 µV/mV + 5.0 µV 0.6 µV/mV + 6.0 µV 1.3 µV/mV + 12 µV 0.3 µV/mV + 5.0 µV 0.12 µV/mV + 5.0 µV 0.1 µV/mV + 5.0 µV 0.25 µV/mV + 5.0 µV 0.6 µV/mV + 6.0 µV 1.3 µV/mV + 12 µV 1.7 µV/mV + 25 µV 3.4 µV/mV + 25 µV 0.3 µV/mV + 15 µV 0.12 µV/mV + 8.0 µV 0.07 µV/mV + 8.0 µV Fluke 5730A
0 to 200 nC
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1592.05) Revised 11/03/2025 Page 5 of 21 Parameter/Range Frequency CMC2, 5 (±) Comments AC Voltage – Generate (cont) (22 to 220) mV (0.22 to 2.2) V (2.2 to 22) V (22 to 220) V (220 to 1100) V (220 to 750) V (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (15 to 50) kHz (50 to 1) kHz (30 to 50) kHz (50 to 100) kHz 0.15 µV/mV + 8.0 µV 0.4 µV/mV + 20 µV 0.8 µV/mV + 25 µV 1.7 µV/mV + 30 µV 3.3 µV/mV + 60 µV 0.3 mV/V + 50 µV 0.11 mV/V + 20 µV 0.048 mV/V + 10 µV 0.08 mV/V + 12 µV 0.1 mV/V + 40 µV 0.4 mV/V + 100 µV 1.2 mV/V + 250 µV 2.0 mV/V + 400 µV 0.3 mV/V + 500 µV 0.11 mV/V + 200 µV 0.048 mV/V + 70 µV 0.08 mV/V + 120 µV 0.1 mV/V + 250 µV 0.4 mV/V + 800 µV 1.2 mV/V + 2.5 mV 2.0 mV/V + 4 mV 0.3 mV/V + 5 mV 0.11 mV/V + 2 mV 0.065 mV/V + 0.7 mV 0.1 mV/V + 1.2 mV 0.18 mV/V + 3 mV 1.1 mV/V + 20 mV 5.4 mV/V + 50 mV 10 mV/V + 100 mV 0.36 mV/V + 20 mV 0.085 mV/V + 4 mV 0.4 mV/V + 11 mV 0.016 V/V + 45 mV Fluke 5730A Fluke 5730A w/ 5725A AC Voltage – Measure (0 to 200) mV (10 to 40) Hz (40 to 100) Hz 100 Hz to 2 kHz 0.17 µV/mV + 14 µV 0.14 µV/mV + 4 µV 0.12 µV/mV + 4 µV Fluke 8508A
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1592.05) Revised 11/03/2025 Page 6 of 21 Parameter/Range Frequency CMC2, 5 (±) Comments AC Voltage – Measure (cont) (0 to 200) mV (0.2 to 2) V (2 to 20) V (20 to 200) V (200 to 1000) V (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (10 to 40) Hz (40 to 100) Hz 100 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (10 to 40) Hz (40 to 100) Hz 100 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (10 to 40) Hz (40 to 100) Hz 100 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz 40 Hz to 10 kHz (10 to 30) kHz 0.11 µV/mV + 2 µV 0.14 µV/mV + 4 µV 0.34 µV/mV + 8 µV 0.15 mV/V + 0.12 mV 0.12 mV/V + 0.02 mV 0.09 mV/V + 0.02 mV 0.075 mV/V + 0.02 mV 0.11 mV/V + 0.02 mV 0.22 mV/V + 0.04 mV 0.57 mV/V + 0.2 mV 10 mV/V + 20 mV 0.15 mV/V + 1.2 mV 0.12 mV/V + 0.2 mV 0.09 mV/V + 0.2 mV 0.075 mV/V + 0.2 mV 0.11 mV/V + 0.2 mV 0.22 mV/V + 2 mV 3 mV/V + 20 mV 10 mV/V + 200 mV 0.12 mV/V + 1.2 mV 0.12 mV/V + 0.2 mV 0.075 mV/V + 0.2 mV 0.11 mV/V + 2 mV 0.22 mV/V + 4 mV 0.57 mV/V + 20 mV 0.12 mV/V + 200 mV 0.23 mV/V + 400 mV Fluke 8508A AC Current – Generate (9 to 220) µA (0.22 to 2.2) mA (10 to 20) Hz (20 to 40) Hz (40 to 1000) Hz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz (40 to 1000) Hz (1 to 5) kHz (5 to 10) kHz 0.27 nA/µA + 2.4 nA 0.13 nA/µA + 89 nA 0.081 nA/µA + 7.3 nA 0.29 nA/µA + 2.6 nA 1.2 nA/µA + 11 nA 0.27 µA/mA + 19 µA 0.17 µA/mA + 21 nA 0.11 µA/mA + 12 nA 0.23 µA/mA + 52 nA 1.2 µA/mA + 0.27 µA Fluke 8508A
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1592.05) Revised 11/03/2025 Page 7 of 21 Parameter/Range Frequency CMC2, 5 (±) Comments AC Current – Generate (cont) (2.2 to 22) mA (22 to 220) mA (0.22 to 2.2) A (0 to 2) A (2 to 20) A (20 to 120) A 120 A to 3 kA 120 A to 1 kA (120 to 300) A (0 to 100) A (0 to 50) A (10 to 20) Hz (20 to 40) Hz (40 to 1000) Hz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz (40 to 1000) Hz (1 to 5) kHz (5 to 10) kHz (20 to 1000) Hz (1 to 5) kHz (5 to 10) kHz (10 to 65) Hz (65 to 300) Hz 300 Hz to 1 kHz (1 to 3) kHz (3 to 6) kHz (6 to 10) kHz (10 to 65) Hz (65 to 300) Hz 300 Hz to 1 kHz (1 to 3) kHz (3 to 6) kHz (6 to 10) kHz 10 to 65) Hz (65 to 300) Hz 300 Hz to 1 kHz (1 to 3) kHz (3 to 6) kHz (6 to 10) kHz (10 to 65) Hz (65 to 300) Hz 300 Hz to 1 kHz (1 to 3) kHz (3 to 6) kHz (6 to 10) kHz 0.31 µA/mA + 0.67 µA 0.19 µA/mA + 0.42 µA 0.17 µA/mA + 0.015 µA 0.23 µA/mA + 0.51 µA 1.2 µA/mA + 2.7 µA 0.29 µA/mA + 2.3 µA 0.17 µA/mA + 0.15 µA 0.12 µA/mA + 0.075 µA 6.6 nA/mA + 2.1 µA 1.2 µA/mA + 0.027 mA 0.13 mA/A + 7.3 µA 0.47 mA/A + 0.24 mA 3.6 mA/A + 0.63 mA 5.9 mA/A + 9.3 mA 0.014 mA/A + 1.1 mA 0.081 mA/A + 1.1 mA 5.9 mA/A + 9.3 mA 1.2 mA/A + 25 mA 1.6 mA/A + 62 mA 0.025 mA/A + 9.4 mA 0.032 mA/A + 9.4 mA 0.081 mA/A + 9.4 mA 0.23 mA/A + 31 mA 0.78 mA/A + 62 mA 2.3 mA/A + 94 mA 0.028 mA/A + 19 mA 0.033 mA/A + 28 mA 0.082 mA/A + 94 mA 0.23 mA/A + 0.23 A 0.78 mA/A + 0.42 A 3.1 mA/A + 0.70 A 1.4 mA/A + 0.84 A 1.4 mA/A + 0.84 A 0.71 mA/A + 0.84 A 1.6 mA/A + 1.2 A 1.7 mA/A + 1.2 A 2.6 mA/A + 1.2 A Fluke 5730A Fluke 52120A / coil Fluke 52120A w/ 25/50 turn coil Fluke 52120A w/ 25 turn coil
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1592.05) Revised 11/03/2025 Page 8 of 21 Parameter/Range Frequency CMC2, 5 (±) Comments AC Current – Measure (0 to 200) µA (0.1 to 2.0) mA (2.0 to 20) mA (20 to 200) mA (0.2 to 2.0) A (2.0 to 20) A 10 Hz to 10 kHz 10 Hz to 10 kHz 10 Hz to 10 kHz 10 Hz to 5 kHz 10 Hz to 2 kHz (2 to 10) kHz 10 Hz to 2 kHz (2 to 10) kHz 0.5 nA/ µA + 22 nA 0.31 µA/mA + 20 µA 0.71 µA/mA + 10 µA 0.29 µA/mA + 10 µA 0.062 mA/A + 0.20 mA 0.074 mA/A + 0.20 mA 0.82 mA/A + 2.0 mA 2.5 mA/A + 2.0 mA Fluke 8508A Oscilloscopes – DC Signal: 50 Ω Load 1 MΩ Load Amplitude Square Wave: 50 Ω, 10 Hz to 10 kHz 1 MΩ: 10 Hz to 1 kHz (1 to 10) kHz Leveled Sine Wave (Into 50 Ω Load) @ 50kHz Reference Flatness @ 50 kHz Reference Time Markers (50 Ω Load) (-6.6 to 6.6) V (-130 to 130) V ± 1 mV to 6.6 V (p-p) ± 1 mV to 130 V (p-p) ± 1 mV to 130 V (p-p) ± 5 mV to 5.5 V (p-p) ± 5 mV to 5.5 V (p-p) 50 kHz to 100 MHz (100 to 300) MHz (300 to 600) MHz ± 5 mV to 3.5 V (p-p) (600 to 1100) MHz 5 s to 50 ms 20 ms to 2 ns 39 mV/V + 40 µV 0.94 mV/V + 40 µV 51 mV/V + 40 µV 0.92 mV/V + 40 µV 2.2 mV/V + 40 µV 0.37 V/V + 0.10 mV 0.35 V/V + 0.10 mV 0.44 V/V + 0.10 mV 0.83 V/V + 0.10 mV 1.1 V/V + 0.10 mV (58 + 1000t) µs/s 5.7 µs/s Fluke 5522A t = time in seconds
9-Oil
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1592.05) Revised 11/03/2025 Page 9 of 21 Parameter/Equipment Range CMC2, 5 (±) Comments Resistance – Generate Fixed Points 0.1 Ω 25 Ω 65 Ω 100 Ω 260 Ω 400 Ω 0 Ω 1 Ω 1.9 Ω 10 Ω 19 Ω 100 Ω 190 Ω 1 kΩ 1.9 kΩ 10 kΩ 19 kΩ 100 kΩ 190 kΩ 1 MΩ 1.9 MΩ 10 MΩ 19 MΩ 100 MΩ 330 MΩ 1.1 GΩ 14 µΩ/Ω 6.1 µΩ/Ω 5.4 µΩ/Ω 5.8 µΩ/Ω 4.9 µΩ/Ω 4.3 µΩ/Ω 46 µΩ 0.10 mΩ 0.18 mΩ 0.25 mΩ 0.49 mΩ 1.1 mΩ 2.1 mΩ 6.9 mΩ 13 mΩ 0.068 Ω 0.13 Ω 0.88 Ω 1.7 Ω 14 Ω 35 Ω 0.42 kΩ 0.94 kΩ 12 kΩ 3.1 MΩ 17 MΩ Leeds & Northrup standard resistor w/ oil bath Fluke 5730A Fluke 5522A Resistance – Measure (0 to 2) Ω (2 to 20) Ω (20 to 200) Ω (0.2 to 2.0) kΩ (2.0 to 20) kΩ (20 to 200) kΩ (0.2 to 2.0) MΩ (2 to 20) MΩ (20 to 200) MΩ (0.2 to 2) GΩ 22 µΩ/Ω + 4.0 µΩ 12 µΩ/Ω + 14 µΩ 9.6 µΩ/Ω + 50 µΩ 9.5 µΩ/Ω + 0.5 mΩ 9.4 µΩ/Ω + 5.0 mΩ 9.6 µΩ/Ω + 50 mΩ 11 µΩ/Ω + 1.0 Ω 30 µΩ/Ω + 0.10 kΩ 0.20 mΩ/Ω + 10 kΩ 1.8 mΩ/Ω + 1 M Ω Fluke 8508A
See scope document
10-Air; Fuel
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1592.05) Revised 11/03/2025 Page 10 of 21 Parameter/Equipment Range CMC2 (±) Comments Electrical Simulation of Thermocouple Indicators & Indicating Systems Type E Type J Type K Type T (-250 to -100) °C (-100 to -25) °C (-25 to 350) °C (350 to 650) °C (650 to 1000) °C (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 1000) °C (1000 to 1372) °C (-250 to -150) °C (-150 to 0) °C (0 to 120) °C (120 to 400) °C 0.50 °C 0.16 °C 0.14 °C 0.16 °C 0.21 °C 0.27 °C 0.16 °C 0.14 °C 0.17 °C 0.23 °C 0.33 °C 0.18 °C 0.16 °C 0.26 °C 0.40 °C 0.63 °C 0.24 °C 0.16 °C 0.14 °C Fluke 5522A IV. Fluid Quantities Parameter/Equipment Range CMC 2, 4, 8 (±) Comments Mass Fuel Flow – Measuring Equipment (10 to 15 000) g/min 0.41 % + 0.59 g/min Gravimetric calibrator (g = gram) Mass Air Flow – Measuring Equipment (20 to 40 000) kg/h (1.3 to 5500) kg/h 0.49 % 0.33 % Subsonic nozzles, critical flow Venturis
See scope document
11FTI Omnitrak OT-400 flow calibration system (gravimetric method); Verification w/ standard weights; Morehouse model-L Deadweight machine; Comparison w/ standard load cellWater; OilSee scope document
12

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1592.05) Revised 11/03/2025 Page 12 of 21 Parameter/Equipment Range CMC2, 4, 8 (±) Comments Pressure – Measuring Equipment (cont) Pneumatic (Absolute Pressure) (6 to 62.2) kPa (>62.2 to 206.9) kPa (104 to 2064.7) kPa (>2064.7 to 6890.3) kPa 0.12 Pa/kPa + 2 Pa 0.14 Pa/kPa + 12 Pa 0.13 Pa/kPa + 40 Pa 0.14 Pa/kPa + 8.6 Pa Fluke PPC4™ pressure controller/ calibrator Rotational Speed, Non- Contact (50 to 5000) RPM 0.30 RPM Phototach & Fluke PM6680B Torque – Measuring Equipment (1 to 8605.9) Nꞏm (0 to 2370) Nꞏm (0 to 5924) Nꞏm (0 to 11 848) Nꞏm (0 to 23 696) Nꞏm (0 to 59 241) Nꞏm 0.019 % + 0.021 Nꞏm 3.5 Nꞏm 8.8 Nꞏm 18 Nꞏm 35 Nꞏm 88 Nꞏm Lever arm w/ NIST class F weights Standard load cells w/ dynamometer Torque Wrenches (4.5 to 23) Nꞏm (27 to 136) Nꞏm (163 to 814) Nꞏm 0.14 Nꞏm 1.7 Nꞏm 2.8 Nꞏm Precision torque transducers Torque – Shafts (0 to 169) Nꞏm (0 to 338) Nꞏm (0 to 847) Nꞏm (0 to 1694) Nꞏm (0 to 3390) Nꞏm (0 to 8474) Nꞏm (0 to 16 948) Nꞏm (0 to 33 895) Nꞏm (0 to 84 739) Nꞏm 0.26 Nꞏm 0.49 Nꞏm 1.2 Nꞏm 2.5 Nꞏm 5.6 Nꞏm 17 Nꞏm 28 Nꞏm 57 Nꞏm 0.13 kNꞏm Torque shaft cal bench w/ arm VI. Thermodynamics Parameter/Equipment Range CMC 2, 8 (±) Comments Temperature, RTD – Measuring Equipment (0 to 99) °C (100 to 150) °C 0.07 °C 0.05 °C SPRT & temperature bath
13-Mechanical Components & Parts
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1592.05) Revised 11/03/2025 Page 13 of 21 Parameter/Equipment Range CMC2, 8 (±) Comments Dew Point – Measuring Equipment (0 to 25) °C 0.20 °C Thunder Scientific 1200 Relative Humidity – Measuring Equipment (10 to 95) % RH 0.83 % RH Thunder Scientific 1200 VII. Time & Frequency Parameter/Equipment Range CMC 2, 8 (±) Comments Frequency – Measuring Equipment 1 µHz to 80 MHz 2.3 x 10 -6 Hz/Hz Agilent 33250A Frequency – Measure 10 Hz to 225 MHz 5.8 x 10-6 Hz/Hz Fluke PM6680B Mechanical Testing Parameter Range Technique / Method Force Testing – Mechanical Components & Parts Tangential Tension Compression & Tension (89 to 445) N (0 to 4.5) N (4.5 to 900) N (900 to 4450) N C-K Engineering tangential tension machine Chatillon TCD-1100 w/ load cell Mass Measurement – Mechanical Components & Parts (0 to 5200) g (0 to 60) kg Sartorious scale Digi Matex scale _____________________________________________
See scope document
14--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1592.05) Revised 11/03/2025 Page 14 of 21 SATELLITE ADVANCED TECHNOLOGY SERVICES – CATERPILLAR TECHNICAL CENTER AC 6132 Dock 29 Rench Rd Route 29 Mossville, IL 61552 Brady Van Hoorebeke Phone: 309 494 5123 CALIBRATION I. Dimensional Parameter Range CMC 2, 8 (±) Comments Linear Displacement, Travel – Measuring Equipment Up to 500 mm 0.055 mm Gage blocks III. Thermodynamics Parameter Range CMC 2, 8 (±) Comments Temperature – Measuring Equipment (-80 to 300) °C 0.27 °C Class B RTD w/ Fluke 1586A Humidity – Measuring Equipment (20 to 80) % RH 3.6 % RH Omega IBTHX-SD _____________________________________________
to 500 mm
15

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1592.05) Revised 11/03/2025 Page 15 of 21 SATELLITE ADVANCED TECHNOLOGY SERVICES - CATERPILLAR PROVING GROUNDS Peoria Proving Ground, 27194 Caterpillar Lane Washington, IL 61571 Brady Van Hoorebeke Phone: 309 494 5123 CALIBRATION I. Acoustical Quantities Parameter/Range Frequency CMC 2, 8 (±) Comments Acoustic Level – Sound Pressure Level Measuring Equipment 94 dB re 2 x 10 -5 Pa (31.5 to 125) Hz (250 to 500) Hz 1 kHz 2 kHz 4 kHz 8 kHz 12.5 kHz 16 kHz 0.63 dB 0.49 dB 0.32 dB 0.56 dB 0.64 dB 0.82 dB 1.8 dB 1.9 dB B&K 4226 multifunction acoustic calibrator & B&K 4231 sound level source II. Dimensional Parameter/Equipment Range CMC 2, 7, 8 (±) Comments Linear Displacement, Travel – Measuring Equipment (0 to 2032) mm (2033 to 7620) mm (5 + 0.16L) µm (15 + 0.23L) µm Heidenhain linear encoder LS106 Angle – Measuring Equipment (0 to 60)° 0.16° Gage blocks w/ sine bar
16

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1592.05) Revised 11/03/2025 Page 16 of 21 III. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 5 (±) Comments DC Voltage – Generate (0 to 330) mV (0 to 3.3) V (3.3 to 33) V (30 to 330) V (100 to 1020) V 0.06 µV/mV + 3 µV 0.05 mV/V + 5 µV 0.05 mV/V + 50 µV 0.055 mV/V + 500 µV 0.055 mV/V + 1500 µV Fluke 5502A DC Voltage – Measure (0 to 100) mV 100 mV to 1 V (1 to 10) V (10 to 100) V (100 to 1000) V (0 to 100) mV 100 mV to 1 V (1 to 10) V (10 to 80) V 90 µV/V + 4.2 µV 47 µV/V + 8.4 µV 36 µV/V + 60 µV 49 µV/V + 0.72 mV 56 µV/V + 10 mV 67 µV/V + 4 µV 210 µV/V + 8.1 µV 200 µV/V + 58 µV 610 µV/V + 1 mV Agilent 34410A Somat cal stand/Keithley 2750 DC Current – Generate (0 to 330) µA (330 to 3.3) mA (3.3 to 33) mA (33 to 330) mA (0 to 1.1) A (1.1 to 3) A (0 to 11) A (11 to 20.5) A (100 to 3000) A 0.15 nA/µA + 0.02 µA 0.13 µA/mA + 0.05 µA 0.1 µA/mA + 0.25 µA 0.1 µA/mA + 2.5 µA 0.38 mA/A + 44 µA 0.38 mA/A + 44 µA 0.6 mA/A + 500 µA 1.0 mA/A + 750 µA 0.015 A Fluke 5502A Current amplifier w/transducers Parameter/Range Frequency CMC2, 5 (±) Comments AC Voltage – Generate (1.0 to 33) mV (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz 1.5 µV/mV + 20 µV 33 µV/mV + 20 µV 66 µV/mV + 20 µV 66 µV/mV + 20 µV 120 µV/mV + 33 µV 330 µV/mV + 60 µV Fluke 5502A
17

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1592.05) Revised 11/03/2025 Page 17 of 21 Parameter/Range Frequency CMC2, 5 (±) Comments AC Voltage – Generate (cont) (33 to 330) mV (0.33 to 3.3) V (3.3 to 33) V (33 to 329) V (330 to 1020) V (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (45 to 1000) Hz (1 to 5) kHz (5 to 10) kHz 0.5 µV/mV + 20 µV 0.3 µV/mV + 20 µV 0.7 µV/mV + 20 µV 1 µV/mV + 40 µV 2.3 µV/mV + 170 µV 5 µV/mV + 330 µV 0.5 mV/V + 60 µV 0.3 mV/V + 60 µV 0.7 mV/V + 60 µV 1.0 mV/V + 60 µV 2.3 mV/V + 200 µV 5 mV/V + 900 µV 0.5 mV/V + 800 µV 0.3 mV/V + 600 µV 0.7 mV/V + 600 µV 1.0 mV/V + 600 µV 2.3 mV/V + 2000 µV 0.5 mV/V + 3.0 mV 0.8 mV/V + 9.0 mV 0.9 mV/V + 9.0 mV 1.2 mV/V + 9.0 mV 2.4 mV/V + 80 mV 0.5 mV/V + 20 mV 0.8 mV/V + 20 mV 0.9 mV/V + 20 mV Fluke 5502A Parameter/Equipment Range CMC2, 5 (±) Comments Resistance – Generate (0 to 11) Ω (11 to 33) Ω (33 to 110) Ω (110 to 330) Ω (0.330 to 1.1) kΩ (1.1 to 3.3) kΩ (3.3 to 11) kΩ (11 to 33) kΩ (33 to 110) kΩ 0.12 mΩ/Ω + 0.01 Ω 0.12 mΩ/Ω + 0.015 Ω 0.09 mΩ/Ω + 0.015 Ω 0.09 mΩ/Ω + 0.02 Ω 0.09 mΩ/Ω + 0.02 Ω 0.09 mΩ/Ω + 0.2 Ω 0.09 mΩ/Ω + 0.1 Ω 0.09 mΩ/Ω + 1 Ω 0.11 mΩ/Ω + 1 Ω Fluke 5502A
18

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1592.05) Revised 11/03/2025 Page 18 of 21 Parameter/Equipment Range CMC2, 5 (±) Comments Resistance – Generate (cont) (110 to 330) kΩ (0.330 to 1.1) MΩ (1.1 to 3.3) MΩ (3.3 to 11) MΩ (33 to 110) MΩ (110 to 330) MΩ (330 to 1100) MΩ 0.12 mΩ/Ω + 10 Ω 0.15 Ω/Ω + 10 Ω 0.15 Ω/Ω + 150 Ω 0.6 Ω/Ω + 250 Ω 0.1 Ω/Ω + 2.5 kΩ 0.5 Ω/Ω + 3 kΩ 1.5 Ω/Ω + 5 MΩ Fluke 5502A Resistance – Measure (0 to 100) Ω 100 Ω to 1 kΩ (1 to 10) kΩ (10 to 100) kΩ 100 kΩ to 1 MΩ (1 to 10) MΩ 100 Ω to 100 kΩ 100 kΩ to 1 MΩ 0.15 mΩ/Ω + 4.8 mΩ 0.12 mΩ/Ω + 12 mΩ 0.12 mΩ/Ω + 12 mΩ 0.12 mΩ/Ω + 1.2 Ω 0.14 mΩ/Ω + 12 Ω 0.49 mΩ/Ω + 0.12 kΩ 1.4 mΩ/Ω + 1.4 Ω 1.9 mΩ/Ω + 1.4 Ω Agilent 34410A Somat cal stand/Keithley 2750 Parameter/Range Frequency CMC2, 5 (±) Comments AC Current – Generate (29 to 330) µA (0.33 to 3.3) mA (3.3 to 33) mA (33 to 330) mA (10 to 20) Hz (20 to 45) Hz (45 to 1000) Hz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz (45 to 1000) Hz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz (45 to 1000) Hz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 2.0 nA/µA + 0.1 µA 1.5 nA/µA + 0.1 µA 1.3 nA/µA + 0.1µA 3.0 nA/µA + 0.15 µA 8.0 nA/µA + 0.2 µA 16 nA/µA + 0.4 µA 2.0 µA/mA + 0.15 µA 1.3 µA/mA + 0.15 µA 1.0 µA/mA + 0.15 µA 2.0 µA/mA + 0.2 µA 5.0 µA/mA + 0.3 µA 10 µA/mA + 0.6 µA 1.8 µA/mA + 2 µA 0.9 µA/mA + 2 µA 0.4 µA/mA + 2 µA 0.8 µA/mA + 2 µA 2.0 µA/mA + 3 µA 4.0 µA/mA + 4 µA 1.8 µA/mA + 20 µA 0.9 µA/mA + 20 µA Fluke 5502A
19

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1592.05) Revised 11/03/2025 Page 19 of 21 Parameter/Range Frequency CMC2, 5 (±) Comments AC Current – Generate (cont) (33 to 330) mA (0.33 to 1.1) A (1.1 to 3) A (3 to 11) A (11 to 20.5) A (45 to 1000) Hz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 45) Hz (45 to 1000) Hz (1 to 5) kHz (5 to 10) kHz (10 to 45) Hz (45 to 1000) Hz (1 to 5) kHz (5 to 10) kHz (45 to 100) Hz (100 to 1000) Hz (1 to 5) kHz (45 to 100) Hz (100 to 1000) Hz (1 to 5) kHz 0.4 µA/mA + 20 µA 1.0 µA/mA + 50 µA 2.0 µA/mA + 100 µA 4.0 µA/mA + 200 µA 1.8 mA/A + 100 µA 0.5 mA/A + 100 µA 6.0 mA/A + 1000 µA 25 mA/A + 5000 µA 1.8 mA/A + 100 µA 0.6 mA/A + 100 µA 6.0 mA/A + 1000 µA 25 mA/A + 5000 µA 0.6 mA/A + 2000 µA 1.0 mA/A + 2000 µA 30 mA/A + 2000 µA 1.2 mA/A + 5000 µA 1.5 mA/A + 5000 µA 30 mA/A + 5000 µA Fluke 5502A Parameter/Equipment Range CMC2 (±) Comments Electrical Simulation of Thermocouple Indicators & Indicating Systems Type E Type J (-250 to -100) °C (-100 to -25) °C (-25 to 350) °C (350 to 650) °C (650 to 1000) °C (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C 0.50 °C 0.16 °C 0.14 °C 0.16 °C 0.21 °C 0.27 °C 0.16 °C 0.14 °C 0.17 °C 0.23 °C Fluke 5502A
20

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1592.05) Revised 11/03/2025 Page 20 of 21 Parameter/Equipment Range CMC2 (±) Comments Electrical Simulation of Thermocouple Indicators & Indicating Systems (cont) Type K Type T (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 1000) °C (1000 to 1372) °C (-250 to -150) °C (-150 to 0) °C (0 to 120) °C (120 to 400) °C 0.33 °C 0.18 °C 0.16 °C 0.26 °C 0.40 °C 0.63 °C 0.24 °C 0.16 °C 0.14 °C Fluke 5502A IV. Mechanical Parameter/Equipment Range CMC 2, 8 (±) Comments Force – Measuring Equipment Up to 966 N (0 to 2224.1) N (0 to 8896.4) N (0 to 22 241.1) N (0 to 1200) kN 0.22 N 6.7 N 29 N 68 N 2 kN NIST Class F weights ATS press & load cells Instron press & load cells Torque – Shafts (0 to 10 000) Nꞏm 22 Nꞏm + 0.0021 Nꞏm/(Nꞏm) Drive shaft calibrator Pressure – Measuring Equipment Hydraulic (Relative Pressure) Pneumatic (Absolute Pressure) 0 kPa to 12 MPa (12 to 40) MPa (40 to 42) MPa (42 to 140) MPa (6 to 689.8) kPa (689.8 to 6894.8) kPa 6.3 kPa 8.9 kPa 7.6 kPa 32 kPa 0.12 kPa 1.2 kPa Fluke PPCH DH Instruments PPC3
21

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1592.05) Revised 11/03/2025 Page 21 of 21 Parameter/Equipment Range CMC2, 4 (±) Comments Vibration - Accelerometers (10 to 99) Hz 100 Hz (101 to 920) Hz (921 to 5000) Hz 5001 Hz to 10 kHz (10 to 15) kHz (15 to 20) kHz 2.2 % 1.9 % 2.0 % 2.4 % 2.8 % 4.5 % 5.4 % Modal Shop 9155C V. Time & Frequency Parameter/Equipment Range CMC2, 8 (±) Comments Frequency – Measuring Equipment 100 Hz to 100 kHz 310 µHz/Hz Somat Cal Stand/Keithley 2750 ____________________________________________ 1 This laboratory is not available for commercial service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 This scope meets A2LA’s P112 Flexible Scope Policy. 4 In the statement of CMC, a percent refers to a percent of reading unless otherwise noted. 5 The measurands stated are generated using the indi cated instrument (see Commen ts). This capability is suitable for the calibration of the devices intended to measure the measurand in the ranges indicated. CMC’s are expressed as either a specific value that cove rs the full range or as a fraction/percentage of the reading plus a fixed floor specification. 6 This laboratory meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program for the types of dimensional tests listed above and is considered equivalent to that of a calibration. 7 In the statement of CMC, L is the numerical value of the nominal length of the device measured in millimeters. 8 The type of instrument or material being calib rated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter.
22ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

14009 Old Galena Rd, Tech Center TCL, Chillicothe, IL, 61523, US

40.91616, -89.48844

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.