SOL SPA
Via Libertà 247, 20900, Monza, Italy
Visit website- Accredited standards
- 6
- ACCREDIA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the ACCREDIA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 6 standard numbers and the 2 official names we hold. When no standard matches, it searches the method text of every scope line.
EN 14211
EN 14212
EN 14626
EN 15984
ISO 12963Gas analysis - Comparison methods for the determination of the composition of gas mixtures based on one- and two-point calibration
ISO 16017-1Indoor, ambient and workplace air - Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography - Part 1: Pumped sampling
ISO 12963:2017; UNI EN ISO 16017-1:2002; UNI CEN/TS 17405:2020; UNI EN 14212:2025; UNI EN 15984:2022; UNI EN 14211:2025; UNI EN 14626:2025
Read from the scope as published by ACCREDIA. Register refreshed 2026-11-06.
Scope as published by ACCREDIA
3 lines
ISO/IEC 17025
Active01045
Accredited scope, certificate 01045
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO 12963:2017; UNI EN ISO 16017-1:2002; UNI CEN/TS 17405:2020; UNI EN 14212:2025; UNI EN 15984:2022; UNI EN 14211:2025; UNI EN 14626:2025 | Miscele gassose sintetiche/Synthetic gaseous mixture - solo/only azoto | 10 to 1000 ppm |
| 2 | EU PHARMA 07/2022:1238 + 01/2017:20528; EU PHARMA 07/2022:1238 + 01/2008:20526; EU PHARMA 07/2022:1238 + 01/2011:20524; EU PHARMA 07/2022:1238; EU PHARMA 07/2022:1238 + 01/2011:20525; EU PHARMA 07/2022:1238 + 01/2018:20106; EU PHARMA 07/2022:1238 + 01/2009:20527; EU PHARMA 01/2008:1684 + 01/2017:20528; EU PHARMA 01/2008:1684 + 01/2009:20527; EU PHARMA 01/2008:0416 + 01/2017:20528; EU PHARMA 01/2008:0416 + 01/2008:20526; EU PHARMA 01/2008:0416 + 01/2018:20106; EU PHARMA 01/2008:0416 + 01/2011:20535; EU PHARMA 01/2010:0417 + 01/2017:20528; EU PHARMA 01/2010:0417 + 01/2011:20524; EU PHARMA 01/2010:0417 + 01/2011:20525 Met. II; EU PHARMA 01/2010:0417 + 01/2009:20527 | Aria Medicale/Medical air; Acqua/Water; Aria Sintetica Medicale/Synthetic medical air; Azoto Protossido Medicale/Medical nitrous oxide; Ossigeno Medicale/Medical oxygen | See scope document |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. SOL SPA
Via Libertà 247
20900 Monza MB
Legenda/Note
Allegato al certificato di accreditamento n. 01045 rev. 5 del 20/11/2025
UNI CEI EN ISO/IEC 17025:2018
Revisione: 15
Sede A
Data: 20/11/2025
pag. 3 di 3
Il simbolo (1), se presente, indica: "Materiale/Prodotto/Matrice" non previsto dal metodo ma assimilabile/The symbol (1), if present, means: Material/Product/Matrix not
provided for by the method but acceptable
Per la definizione della “categoria" di prova indicata nel titolo, si veda il Regolamento Generale ACCREDIA RG-02/For the definition of the test “category” indicated in the title,
see ACCREDIA General Regulation RG-02.
Il QRcode consente di accedere direttamente al sito www.accredia.it per verificare la validità dell'elenco prove e del certificato di accreditamento
rilasciato al laboratorio/The QRcode allows to directly access to the website www.accredia.it to verify the validity of the test list and of the
accreditation certificate issued to the laboratory.
L’eventuale simbolo “X” riportato nella colonna “O&I” indica che il laboratorio è accreditato anche per fornire opinioni e interpretazioni basate sui
risultati delle specifiche prove contrassegnate/Any "X" symbol in the "O&I" column indicates that the laboratory is also accredited to provide opinions
and interpretations based on the results of the specific marked tests.
L'eventuale simbolo (*) indica che è attiva una sospensione dell’accreditamento per la specifica attività riportata a fianco/Any symbol (*) indicates that
a suspension of accreditation is active for the specific activity shown next to it. | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the ACCREDIA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ACCREDIA entry linked above.