Registers refreshed 2026-11-20.See refresh dates
Finland

Eleforss

FINAS T313ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
45
FINAS certificate
1
Sites in our directory
2
FINAS accredited scope

What this lab is accredited for

Our reading of the FINAS scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 45 standard numbers and the 31 official names we hold. When no standard matches, it searches the method text of every scope line.

ETSI15
ETSI EN 300 220-1
ETSI EN 300 220-2
ETSI EN 300 328Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz band; Harmonised Standard for access to radio spectrum
ETSI EN 300 330Short Range Devices (SRD); Radio equipment in the frequency range 9 kHz to 25 MHz and inductive loop systems in the frequency range 9 kHz to 30 MHz; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
ETSI EN 300 440
ETSI EN 301 489-1
ETSI EN 301 489-3
ETSI EN 301 489-7
ETSI EN 301 489-17
ETSI EN 301 489-19
ETSI EN 301 489-24
ETSI EN 301 489-52
ETSI EN 301 511Global System for Mobile communications (GSM); Mobile Stations (MS) equipment; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
ETSI EN 301 908-1
ETSI TS 151 010-1
IEC 61000 series11
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test

Certificate says EN 61000-4-3. Probably the same standard; not checked against the EN document.

IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 61000-4-29Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments

Certificate says EN 61000-6-3. Probably the same standard; not checked against the EN document.

IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
CISPR8
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement

Certificate says EN 55011, IEC 55011. Probably the same standard; not checked against the EN document.

CISPR 15Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment

Certificate says EN 55015, IEC 55015. Probably the same standard; not checked against the EN document.

CISPR 16-2-1Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurements

Certificate says EN 55016-2-1. Probably the same standard; not checked against the EN document.

CISPR 16-2-3Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements

Certificate says EN 55016-2-3. Probably the same standard; not checked against the EN document.

CISPR 22Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement

Certificate says EN 55022. Probably the same standard; not checked against the EN document.

CISPR 24Information technology equipment - Immunity characteristics - Limits and methods of measurement

Certificate says EN 55024. Probably the same standard; not checked against the EN document.

CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements

Certificate says EN 55032. Probably the same standard; not checked against the EN document.

CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirements

Certificate says EN 55035. Probably the same standard; not checked against the EN document.

EN4
EN 12015Electromagnetic compatibility - Product family standard for lifts, escalators and moving walks - Emission
EN 12016
EN 50121-3-2Railway applications - Electromagnetic compatibility - Part 3-2: Rolling stock - Apparatus
EN 50155Railway applications - Rolling stock - Electronic equipment
IEC4
IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
IEC 61547Equipment for general lighting purposes - EMC immunity requirements

Certificate says EN 61547. Probably the same standard; not checked against the EN document.

IEC 61800-3Adjustable speed electrical power drive systems - Part 3: EMC requirements and specific test methods for PDS and machine tools
IEC 61800-5-2
Other standards3
FCC PART 15Radio Frequency Devices
ISO 8102-1Electrical requirements for lifts, escalators and moving walks - Part 1: Electromagnetic compatibility with regard to emission
ISO 8102-2Electrical requirements for lifts, escalators and moving walks - Part 2: Electromagnetic compatibility with regard to immunity

Read from the FINAS scope document we downloaded on 2026-08-05. Register refreshed 2026-11-20.

Scope as published by FINAS

15 lines
FINAS

ISO/IEC 17025

Active

T313

The scope document we hold says it is valid until 2029-12-07.

View scope

Other Locations

1 other site in this organization

Accreditation data refreshed from the FINAS register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the FINAS entry linked above.