FindTestingLabs
Registers collected 2026-08-22.See collection dates
Italy

GAIAMBIENTE

Via G.B. Maddalena 5 - Loc Grions del Torre, 33040, Povoletto, Italy

ACCREDIA|01024ISO/IEC 17025Register collected 2026-08-22
Certificates
1
Scope items
5
Locations
1

Contact this laboratory

Watch this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at GAIAMBIENTE?

Claim this profile to keep it accurate.

Claim this profile

Register record

ACCREDIACollected
01024Active

Certificates and scope

1
ACCREDIA

ISO/IEC 17025

Active

01024

View scope

Accredited scope, certificate 01024

DisciplineMethodMatrixRange
biologicalAPAT CNR IRSA 7080 Man 29 2003; APAT CNR IRSA 2090 A Man 29 2003; APAT CNR IRSA 2060 Man 29 2003; APAT CNR IRSA 2030 Man 29 2003; UNI EN ISO 6222:2001; UNI EN ISO 16266:2008; UNI EN ISO 7899-2:2003; UNI EN ISO 9308-1:2017Acque destinate al consumo umano (1)/Drinking waters (1); Acque di fiume/River waters; Acque di lago/Lake waters; Acque di scarico anche sottoposte a trattamento/Waste waters also treated; Acque sotterranee (1)/Ground waters (1); Acque superficiali/Surface waters; Acque trattate (1)/Treated waters (1); Acque di processo (1)/Process waters (1); Acque dolci/Fresh waters; Acque naturali/Natural waters; Percolati (1)/Leachates (1); Rifiuti liquidi acquosi (1)/Aqueous liquid wastes (1); Acque di piscina (1)/Swimming pool waters (1); Acque minerali naturali/Natural mineral waters; Acque pulite/Clean waters; Acque naturali con bassa contaminazione microbica/Natural water with low bacteria numbers2 to 12 unità di pH
chemicalAPAT CNR IRSA 7030 C Man 29 2003; APAT CNR IRSA 2090 B Man 29 2003; APAT CNR IRSA 3010 B + 3020 Man 29 2003; APAT CNR IRSA 3020 Man 29 2003; EPA 3015A 2007; EPA 6020B 2014; APAT CNR IRSA 5130 Man 29 2003; UNI EN 17503:2022; ISO 16649-2:2001; UNI EN ISO 6579-1:2020; ISO 4833-1:2013/Amd 1:2022; UNI EN 15408:2011 + UNI EN ISO 10304-1:2009; UNI EN ISO 21663:2021; UNI EN ISO 21656:2021; UNI EN ISO 21644:2021; UNI EN ISO 21654:2022Waste water15 to 6700 mg/l; KJ/Kg
chemicalUNI CEI EN ISO/IEC 17025:2018; UNI EN ISO 3884:2025; EPA 6020B 2014; UNI 10780:1998; DM 17/06/2002 GU n 220 19/09/2002; UNI EN 13284-1:2017; EPA 3051A 2007; EPA 6020B 2014; EPA 3051A 2007; EPA 6010D 2018; UNI EN 15934:2012; CNR IRSA 1 Q 64 Vol 3 1985 + APAT CNR IRSA 2060 Man 29 2003; UNI EN 12457-2:2004; UNI EN ISO 17294-2:2023; UNI EN 12457-2:2004; UNI EN ISO 11885:2009; UNI EN 12457-2:2004; APAT CNR IRSA 4020 Man 29 2003; UNI EN 12457-2:2004; APAT CNR IRSA 2060 Man 29 2003Stationary source emissionsto 50 mg/m3
chemicalEPA 3051A 2007; EPA 6020B 2014; EPA 3051A 2007; EPA 6010D 2018; UNI 10667-17:2021 + UNI EN 15408:2011 + UNI EN ISO 10304-1:2009; UNI 10667-17:2021 + UNI EN ISO 3884:2025 + UNI EN ISO 17294-2:2023; UNI 10667-17:2021 + UNI EN ISO 3884:2025 + UNI EN ISO 11885:2009; UNI 10667-17:2021 + UNI EN ISO 21663:2021; UNI 10667-17:2021 + UNI EN ISO 21654:2022; UNI EN 14039:2005; UNI EN 13657:2004, UNI EN ISO 11885:2009; DM 13/09/1999 SO n 185 GU n 248 21/10/1999 Met II.3; DM 13/09/1999 SO n 185 GU n 248 21/10/1999 Met II.2; DM 13/09/1999 SO n 185 GU n 248 21/10/1999 Met II.1; UNI EN 13284-1:2017; Rapporti ISTISAN 2013/37 pag 49; UNI EN ISO 16703:2011Soil10 to 1000 g/kg
environmentalUNI CEI EN ISO/IEC 17025:2018; UNI CEN/TS 17405:2020; UNI EN 14789:2017; UNI EN 14790:2017; UNI EN ISO 16911-1:2013Stationary source emissions0.06 to 40 %

Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one.

Location

Via G.B. Maddalena 5 - Loc Grions del Torre, Povoletto, 33040, IT

46.11818, 13.29880

Open in Maps

Accreditation data collected from the ACCREDIA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ACCREDIA entry linked above.