FindTestingLabs
Registers refreshed 2026-09-25.See refresh dates
Poland

PROEKO ŁOMŻA Daniel Just

ul. Księcia Janusza I nr 1, 18-400, Łomża, Poland

PCA|AB 919ISO/IEC 17025Register refreshed 2026-09-25
Certificates
1
Scope items
4
Standards
14
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at PROEKO ŁOMŻA Daniel Just?

Claim this profile to keep it accurate.

Register record

PCARefreshed
AB 919Active

Accredited standards

14

Our reading of the PCA scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.

EN

EN 1911Stationary source emissions - Determination of mass concentration of gaseous chlorides expressed as HCl - Standard reference method
As written on the certificate · Line 3 (PCA AB 919)

PN-EN 14792:2017-04; PN-EN 12619:2013-05; PN-Z-04008-4:1999; PN-EN 13649:2005; PN-EN 1911:2011; ISO 15713:2006; PN-EN 14385:2005; PN-EN 14790:2017-04; PN-EN 13211+AC:2006

EN 12619Stationary source emissions - Determination of the mass concentration of total gaseous organic carbon - Continuous flame ionisation detector method
As written on the certificate · Line 3 (PCA AB 919)

PN-EN 14792:2017-04; PN-EN 12619:2013-05; PN-Z-04008-4:1999; PN-EN 13649:2005; PN-EN 1911:2011; ISO 15713:2006; PN-EN 14385:2005; PN-EN 14790:2017-04; PN-EN 13211+AC:2006

EN 13211Air quality - Stationary source emissions - Manual method of determination of the concentration of total mercury
As written on the certificate · Line 3 (PCA AB 919)

PN-EN 14792:2017-04; PN-EN 12619:2013-05; PN-Z-04008-4:1999; PN-EN 13649:2005; PN-EN 1911:2011; ISO 15713:2006; PN-EN 14385:2005; PN-EN 14790:2017-04; PN-EN 13211+AC:2006

EN 13284-1Stationary source emissions - Determination of low range mass concentration of dust - Part 1: Manual gravimetric method
As written on the certificate · Line 2 (PCA AB 919)

PN-Z-04030-7:1994; PN-EN 13284-1:2018-02; PN-ISO 10396:2001; PN-EN 14789:2017-04; PN-EN 15058:2017-04

EN 13649Name not checked yet
As written on the certificate · Line 3 (PCA AB 919)

PN-EN 14792:2017-04; PN-EN 12619:2013-05; PN-Z-04008-4:1999; PN-EN 13649:2005; PN-EN 1911:2011; ISO 15713:2006; PN-EN 14385:2005; PN-EN 14790:2017-04; PN-EN 13211+AC:2006

EN 14385Stationary source emissions - Determination of the total emission of As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl and V
As written on the certificate · Line 3 (PCA AB 919)

PN-EN 14792:2017-04; PN-EN 12619:2013-05; PN-Z-04008-4:1999; PN-EN 13649:2005; PN-EN 1911:2011; ISO 15713:2006; PN-EN 14385:2005; PN-EN 14790:2017-04; PN-EN 13211+AC:2006

EN 14789Stationary source emissions - Determination of volume concentration of oxygen - Standard reference method: Paramagnetism
As written on the certificate · Line 2 (PCA AB 919)

PN-Z-04030-7:1994; PN-EN 13284-1:2018-02; PN-ISO 10396:2001; PN-EN 14789:2017-04; PN-EN 15058:2017-04

EN 14790Stationary source emissions - Determination of the water vapour in ducts - Standard reference method
As written on the certificate · Line 3 (PCA AB 919)

PN-EN 14792:2017-04; PN-EN 12619:2013-05; PN-Z-04008-4:1999; PN-EN 13649:2005; PN-EN 1911:2011; ISO 15713:2006; PN-EN 14385:2005; PN-EN 14790:2017-04; PN-EN 13211+AC:2006

EN 14792Stationary source emissions - Determination of mass concentration of nitrogen oxides - Standard reference method: Chemiluminescence
As written on the certificate · Line 3 (PCA AB 919)

PN-EN 14792:2017-04; PN-EN 12619:2013-05; PN-Z-04008-4:1999; PN-EN 13649:2005; PN-EN 1911:2011; ISO 15713:2006; PN-EN 14385:2005; PN-EN 14790:2017-04; PN-EN 13211+AC:2006

EN 15058Stationary source emissions - Determination of the mass concentration of carbon monoxide - Standard reference method: non-dispersive infrared spectrometry
As written on the certificate · Line 2 (PCA AB 919)

PN-Z-04030-7:1994; PN-EN 13284-1:2018-02; PN-ISO 10396:2001; PN-EN 14789:2017-04; PN-EN 15058:2017-04

ISO

ISO 10396Stationary source emissions - Sampling for the automated determination of gas emission concentrations for permanently-installed monitoring systems
As written on the certificate · Line 2 (PCA AB 919)

PN-Z-04030-7:1994; PN-EN 13284-1:2018-02; PN-ISO 10396:2001; PN-EN 14789:2017-04; PN-EN 15058:2017-04

ISO 15713Stationary source emissions - Sampling and determination of gaseous fluoride content
As written on the certificate · Line 3 (PCA AB 919)

PN-EN 14792:2017-04; PN-EN 12619:2013-05; PN-Z-04008-4:1999; PN-EN 13649:2005; PN-EN 1911:2011; ISO 15713:2006; PN-EN 14385:2005; PN-EN 14790:2017-04; PN-EN 13211+AC:2006

ISO 21877Stationary source emissions— Determination of the mass concentration of ammonia - Manual method
As written on the certificate · Line 4 (PCA AB 919)

PN-EN ISO 21877:2020-03; Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r.

Other standards

PN-Z-04030-7:1994Name not checked yet
As written on the certificate · Line 2 (PCA AB 919)

PN-Z-04030-7:1994; PN-EN 13284-1:2018-02; PN-ISO 10396:2001; PN-EN 14789:2017-04; PN-EN 15058:2017-04

Scope as published by PCA

4 lines
PCA

ISO/IEC 17025

Active

AB 919

The scope document we hold says it is valid until 2028-06-22.

View on PCA

Accredited scope, certificate AB 919

LineDisciplineMethodMatrixRange
1chemical-General environment-
2chemicalPN-Z-04030-7:1994; PN-EN 13284-1:2018-02; PN-ISO 10396:2001; PN-EN 14789:2017-04; PN-EN 15058:2017-04Flue gas0.1 to 6250 mg/m3; %; m/s; g/m³
3environmentalPN-EN 14792:2017-04; PN-EN 12619:2013-05; PN-Z-04008-4:1999; PN-EN 13649:2005; PN-EN 1911:2011; ISO 15713:2006; PN-EN 14385:2005; PN-EN 14790:2017-04; PN-EN 13211+AC:2006Flue gas1.4 to 4100 mg/m3; % obj.
4environmentalPN-EN ISO 21877:2020-03; Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r.Flue gas28 to 136 dB

Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

ul. Księcia Janusza I nr 1, Łomża, 18-400, PL

53.17507, 22.07276

Open in Maps

Accreditation data refreshed from the PCA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the PCA entry linked above.