PROEKO ŁOMŻA Daniel Just
ul. Księcia Janusza I nr 1, 18-400, Łomża, Poland
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at PROEKO ŁOMŻA Daniel Just?
Claim this profile to keep it accurate.
Register record
- PCARefreshed
- AB 919Active
Accredited standards
14Our reading of the PCA scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.
EN
EN 1911Stationary source emissions - Determination of mass concentration of gaseous chlorides expressed as HCl - Standard reference method
PN-EN 14792:2017-04; PN-EN 12619:2013-05; PN-Z-04008-4:1999; PN-EN 13649:2005; PN-EN 1911:2011; ISO 15713:2006; PN-EN 14385:2005; PN-EN 14790:2017-04; PN-EN 13211+AC:2006
EN 12619Stationary source emissions - Determination of the mass concentration of total gaseous organic carbon - Continuous flame ionisation detector method
PN-EN 14792:2017-04; PN-EN 12619:2013-05; PN-Z-04008-4:1999; PN-EN 13649:2005; PN-EN 1911:2011; ISO 15713:2006; PN-EN 14385:2005; PN-EN 14790:2017-04; PN-EN 13211+AC:2006
EN 13211Air quality - Stationary source emissions - Manual method of determination of the concentration of total mercury
PN-EN 14792:2017-04; PN-EN 12619:2013-05; PN-Z-04008-4:1999; PN-EN 13649:2005; PN-EN 1911:2011; ISO 15713:2006; PN-EN 14385:2005; PN-EN 14790:2017-04; PN-EN 13211+AC:2006
EN 13284-1Stationary source emissions - Determination of low range mass concentration of dust - Part 1: Manual gravimetric method
PN-Z-04030-7:1994; PN-EN 13284-1:2018-02; PN-ISO 10396:2001; PN-EN 14789:2017-04; PN-EN 15058:2017-04
EN 13649Name not checked yet
PN-EN 14792:2017-04; PN-EN 12619:2013-05; PN-Z-04008-4:1999; PN-EN 13649:2005; PN-EN 1911:2011; ISO 15713:2006; PN-EN 14385:2005; PN-EN 14790:2017-04; PN-EN 13211+AC:2006
EN 14385Stationary source emissions - Determination of the total emission of As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl and V
PN-EN 14792:2017-04; PN-EN 12619:2013-05; PN-Z-04008-4:1999; PN-EN 13649:2005; PN-EN 1911:2011; ISO 15713:2006; PN-EN 14385:2005; PN-EN 14790:2017-04; PN-EN 13211+AC:2006
EN 14789Stationary source emissions - Determination of volume concentration of oxygen - Standard reference method: Paramagnetism
PN-Z-04030-7:1994; PN-EN 13284-1:2018-02; PN-ISO 10396:2001; PN-EN 14789:2017-04; PN-EN 15058:2017-04
EN 14790Stationary source emissions - Determination of the water vapour in ducts - Standard reference method
PN-EN 14792:2017-04; PN-EN 12619:2013-05; PN-Z-04008-4:1999; PN-EN 13649:2005; PN-EN 1911:2011; ISO 15713:2006; PN-EN 14385:2005; PN-EN 14790:2017-04; PN-EN 13211+AC:2006
EN 14792Stationary source emissions - Determination of mass concentration of nitrogen oxides - Standard reference method: Chemiluminescence
PN-EN 14792:2017-04; PN-EN 12619:2013-05; PN-Z-04008-4:1999; PN-EN 13649:2005; PN-EN 1911:2011; ISO 15713:2006; PN-EN 14385:2005; PN-EN 14790:2017-04; PN-EN 13211+AC:2006
EN 15058Stationary source emissions - Determination of the mass concentration of carbon monoxide - Standard reference method: non-dispersive infrared spectrometry
PN-Z-04030-7:1994; PN-EN 13284-1:2018-02; PN-ISO 10396:2001; PN-EN 14789:2017-04; PN-EN 15058:2017-04
ISO
ISO 10396Stationary source emissions - Sampling for the automated determination of gas emission concentrations for permanently-installed monitoring systems
PN-Z-04030-7:1994; PN-EN 13284-1:2018-02; PN-ISO 10396:2001; PN-EN 14789:2017-04; PN-EN 15058:2017-04
ISO 15713Stationary source emissions - Sampling and determination of gaseous fluoride content
PN-EN 14792:2017-04; PN-EN 12619:2013-05; PN-Z-04008-4:1999; PN-EN 13649:2005; PN-EN 1911:2011; ISO 15713:2006; PN-EN 14385:2005; PN-EN 14790:2017-04; PN-EN 13211+AC:2006
ISO 21877Stationary source emissions— Determination of the mass concentration of ammonia - Manual method
PN-EN ISO 21877:2020-03; Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r.
Other standards
PN-Z-04030-7:1994Name not checked yet
PN-Z-04030-7:1994; PN-EN 13284-1:2018-02; PN-ISO 10396:2001; PN-EN 14789:2017-04; PN-EN 15058:2017-04
Scope as published by PCA
4 lines
ISO/IEC 17025
ActiveAB 919
The scope document we hold says it is valid until 2028-06-22.
Accredited scope, certificate AB 919
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | chemical | - | General environment | - |
| 2 | chemical | PN-Z-04030-7:1994; PN-EN 13284-1:2018-02; PN-ISO 10396:2001; PN-EN 14789:2017-04; PN-EN 15058:2017-04 | Flue gas | 0.1 to 6250 mg/m3; %; m/s; g/m³ |
| 3 | environmental | PN-EN 14792:2017-04; PN-EN 12619:2013-05; PN-Z-04008-4:1999; PN-EN 13649:2005; PN-EN 1911:2011; ISO 15713:2006; PN-EN 14385:2005; PN-EN 14790:2017-04; PN-EN 13211+AC:2006 | Flue gas | 1.4 to 4100 mg/m3; % obj. |
| 4 | environmental | PN-EN ISO 21877:2020-03; Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. | Flue gas | 28 to 136 dB |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Poland
- "Energopomiar"Gliwice · ~396 kmPCAShares 5 accredited methods and materialsEN 12619:2013-05EN ISO 21877:2020-03PN-Z-04030-7:1994
- CE2 Tech Consulting M. Dziewa i Wspólnicy Sp. j.Toruń · ~233 kmPCAShares 4 accredited methods and materialsEN 12619:2013-05EN ISO 21877:2020-03PN-Z-04030-7:1994
- SBB Laboratorium Badań i EkspertyzKatowice · ~391 kmPCAShares 4 accredited methods and materialsEN 12619:2013-05EN ISO 21877:2020-03PN-Z-04030-7:1994
- Zakład Wykonywania Pomiarów EMITOROpole · ~397 kmPCAShares 4 accredited methods and materialsEN 12619:2013-05PN-Z-04030-7:1994Flue gas
- ZEC DIAGPOMWrocław · ~415 kmPCAShares 4 accredited methods and materialsEN ISO 21877:2020-03PN-Z-04030-7:1994Flue gas
Accreditation data refreshed from the PCA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the PCA entry linked above.