Ingenieurbüro Axel C. Rahn GmbH Die Bauphysiker
Lützowstraße 70, 10785, Berlin, Germany
- Accredited standards
- 2
- DAKKS certificates
- 2
- Site in our directory
- 1
What this lab is accredited for
Our reading of the DAKKS scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 2 standard numbers and the 0 official names we hold. When no standard matches, it searches the method text of every scope line.
45688:2014
DIN 45680
DIN 45688:2014; TA Lärm 1998-08 (Stand 2017); TA Lärm 1968-07; VDI 2058 Blatt 1:1985-09; 16. BImSchV 1990-06; 18. BImSchV 1991-07; DIN 45680 1997-03; AVV Baulärm 1970-08
DIN 45688:2014; TA Lärm 1998-08 (Stand 2017); TA Lärm 1968-07; VDI 2058 Blatt 1:1985-09; 18. BImSchV 1991-07; DIN 45680 1997-03; AVV Baulärm 1970-08
Read from the scope as published by DAKKS. Register refreshed 2026-11-06.
Scope as published by DAKKS
6 lines
ISO/IEC 17025
ActiveD-PL-20724-01-00
Accredited scope, certificate D-PL-20724-01-00
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | DIN EN ISO/IEC 17025 | - | - |
| 2 | DIN 45688:2014; TA Lärm 1998-08 (Stand 2017); TA Lärm 1968-07; VDI 2058 Blatt 1:1985-09; 18. BImSchV 1991-07; DIN 45680 1997-03; AVV Baulärm 1970-08 | - | - |
| 3 | LAI-Freizeitlärm-RL 2015 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
ISO/IEC 17025
ActiveD-PL-20724-01-01
Accredited scope, certificate D-PL-20724-01-01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | DIN EN ISO/IEC 17025:2018 | - | - |
| 2 | DIN 45688:2014; TA Lärm 1998-08 (Stand 2017); TA Lärm 1968-07; VDI 2058 Blatt 1:1985-09; 16. BImSchV 1990-06; 18. BImSchV 1991-07; DIN 45680 1997-03; AVV Baulärm 1970-08 | - | - |
| 3 | LAI -Freizeitlärm -RL 2015 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Germany
- ALB Akustiklabor Berlin Albrecht, Deter, Passow Partnerschaft von Ingenieuren mbBBerlin · ~8 kmDAKKSShares 1 accredited test method45688:2014
- Big-M Büro für ingenieurgeophysikalische MessungenWeitenhagen · ~173 kmDAKKSShares 1 accredited test method45688:2014
- WIND - consult Ingenieurgesellschaft für umweltschonende Energiewandlung mbHAdmannshagen-Bargeshagen · ~201 kmDAKKSShares 1 accredited test method45688:2014
- ITA Ingenieurgesellschaft für Technische Akustik Weimar mbHWeimar · ~226 kmDAKKSShares 1 accredited test method45688:2014
- ted technologie entwicklungen & dienstleistungenBremerhaven · ~340 kmDAKKSShares 1 accredited test method45688:2014
Accreditation data refreshed from the DAKKS register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.