Minnesota Department of Health
601 Robert Street North, 55155, Saint Paul, MN, United States
- Accredited standards
- 11
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 11 standard numbers and the 2 official names we hold. When no standard matches, it searches the method text of every scope line.
EPA10
EPA 200.7
EPA 200.8
EPA 300.1
EPA 350.1
EPA 351.2
EPA 353.2
EPA 365.1
EPA 533
EPA 1633
EPA 8260Volatile Organic Compounds by Gas Chromatography/Mass Spectrometry
Other standards1
ISO 17294-2Water quality - Application of inductively coupled plasma mass spectrometry (ICP-MS) - Part 2: Determination of selected elements including uranium isotopes
SM 2320 B-2011; EPA 350.1; EPA 353.2; EPA 351.2; EPA 200.7; EPA 200.8; ISO/IEC 17025:2017
EPA 200.8; SM 2340 B-2011; EPA 300.1; SM 10200 H-2011; SM 9223 B-2004; EPA 365.1; SM 4500-P F-2011; SM 2540 D-2011; SM 2540 E-2011; SM 4500-H+ B-2011; SM 2130 B-2011; MDH Performance-Based Method (MDH 522); EPA 533
EPA 533; EPA 1633 mod
EPA 1633 mod; EPA 8260D
EPA 8260D; EPA 1633 mod
EPA 1633 mod
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-06.
Scope as published by A2LA
7 lines
ISO/IEC 17025
Active5403.01
The scope document we hold says it is valid until 2027-03-31.
Accredited scope, certificate 5403.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | SM 2320 B-2011; EPA 350.1; EPA 353.2; EPA 351.2; EPA 200.7; EPA 200.8; ISO/IEC 17025:2017 | Non-potable water | - |
| 2 | EPA 200.8; SM 2340 B-2011; EPA 300.1; SM 10200 H-2011; SM 9223 B-2004; EPA 365.1; SM 4500-P F-2011; SM 2540 D-2011; SM 2540 E-2011; SM 4500-H+ B-2011; SM 2130 B-2011; MDH Performance-Based Method (MDH 522); EPA 533 | Non-potable water | - |
| 3 | EPA 533; EPA 1633 mod | Non-potable water | - |
| 4 | EPA 1633 mod; EPA 8260D | Non-potable water | - |
| 5 | EPA 8260D; EPA 1633 mod | Non-potable water | - |
| 6 | EPA 1633 mod | - | - |
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests to which this accreditation applies, please refer to the laboratory’s Chemical Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
MINNESOTA DEPARTMENT OF HEALTH
Saint Paul, MN
for technical competence in the field of
Chemical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 17th day of February 2025.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 5403.01
Valid to March 31, 2027 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Eurofins Lancaster Laboratories Environment TestingLancaster, PA · ~1,477 kmA2LAShares 4 accredited methods and materialsEPA 200.7EPA 200.8EPA 8260D
- Pace Analytical Services, LLC - Minneapolis MNMinneapolis, MN · ~14 kmA2LAShares 2 accredited methods and materialsEPA 8260DNon-potable water
- EMSL AnalyticalIndianapolis, IN · ~810 kmA2LAShares 2 accredited methods and materialsEPA 200.8Non-potable water
- Tennessee Department of Health, Division of Laboratory Services, Environmental ChemistryNashville, TN · ~1,113 kmA2LAShares 2 accredited methods and materialsEPA 200.8Non-potable water
- Elevation DiagnosticsAurora, CO · ~1,124 kmA2LAShares 2 accredited methods and materialsEPA 8260DNon-potable water
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.