Registers refreshed 2026-11-20.See refresh dates
United States

Skorchtek

11520 Blair St., 49424, Holland, MI, United States

Visit website
A2LA 5307.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
4
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 4 scope lines.

A2LA certificate 5307.01 · 4 lines

LineMethodMatrixRange
1

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5307.01) 08/06/2025 Page 1 of 3 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 SKORCHTEK, LLC 11520 Blair St. Holland, MI 49424 Andrew Cogbill Phone: 616 345 0407 CALIBRATION Valid To: May 31, 2027 Certificate Number: 5307.01 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 4: I. Electrical – DC/Low Frequency Parameter/Range Frequency CMC2, 3, 6 (±) Comments AC Voltage – Measure Vibration Controllers: Up to 100 mV 100 mV to 1 V (1 to 10) V (3 to 5) Hz (5 to 10) Hz (10 to 20 000) Hz (3 to 5) Hz (5 to 10) Hz (10 to 20 000) Hz (3 to 5) Hz (5 to 10) Hz (10 to 20 000) Hz 0.63 % 0.5 % 0.23 % 0.62 % 0.48 % 0.21 % 0.61 % 0.19 % 0.25 % Keysight 34465A
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5307.01) 08/06/2025 Page 2 of 3 Parameter/Range Frequency CMC2, 3, 6 (±) Comments Frequency – Measure (Hz) (3 to 10) Hz (10 to 100) Hz (100 to 1000) Hz (1000 to 50 000) Hz 0.19 % 0.14 % 0.14 % 0.14 % Keysight 34465A Parameter/Equipment Range CMC2, 3, 6 (±) Comments DC Voltage – Measure (DCV) Up to 100 mV 100 mV to 1 V (1 to 10) V 0.17 % 0.14 % 0.14 % Keysight 34465A II. Mechanical Parameter/Equipment Range CMC2, 3 (±) Comments Vibration – Accelerometers (g) (1 to 20) Hz (20 to 100) Hz (100 to 2500) Hz (2500 to 10 000) Hz 2.5 % 2.6 % 2.8 % 3.6 % Comparison to a reference transducer ________________________________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 In the statement of CMC, percentages are to be read as percent of reading unless otherwise noted. 4 This scope meets A2LA’s P112 Flexible Scope Policy.
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5307.01) 08/06/2025 Page 3 of 3 5 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 6 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as eith er a specific value that covers the full range or as a fraction/percentage of the reading plus a fixed floor specification.
4ISO/IEC 17025:2017; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

11520 Blair St., Holland, MI, 49424, US

42.78760, -86.10908

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.