Eclipse Laboratories
1025 North Highway 3, 55057, NORTHFIELD, MN, United States
Visit website- Accredited standards
- 5
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 5 standard numbers and the 5 official names we hold. When no standard matches, it searches the method text of every scope line.
ISO 7810Identification cards - Physical characteristics
ISO/IEC 10373-1Cards and security devices for personal identification - Test methods - Part 1: General characteristicsExclusion
Limits written next to it
Resistance to Chemicals ISO/IEC 10373-1 (Section 5.5 except Salt Mist)
ISO/IEC 10373-2Identification cards - Test methods - Part 2: Cards with magnetic stripes
ISO/IEC 18745-1Test methods for machine readable travel documents (MRTD) and associated devices - Part 1: Physical test methods for passport books (durability)
ISO/IEC 24789-2Identification cards - Card service life - Part 2: Methods of evaluation
ISO/IEC 10373-1; ISO/IEC 7810; ANSI/INCITS 322; ISO/IEC 10373-2; ISO/IEC 24789-2; ISO/IEC 18745-1
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
3 lines
ISO/IEC 17025
Active4200.01
The scope document we hold says it is valid until 2027-03-31.
Accredited scope, certificate 4200.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 10373-1; ISO/IEC 7810; ANSI/INCITS 322; ISO/IEC 10373-2; ISO/IEC 24789-2; ISO/IEC 18745-1 | cards | - |
| 2 | ANSI/INCITS 322 | - | - |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
ECLIPSE LABORATORIES
Northfield, MN
for technical competence in the field of
Mechanical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 7th day of May 2025.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 4200.01
Valid to March 31, 2027 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.