Registers refreshed 2026-11-20.See refresh dates
United Kingdom

MAC Clinical Research Finance

Laboratory Services, Floor 3, CityLabs 1.0, Nelson Street, M13 9NQ, Manchester, United Kingdom

Visit website
UKAS 29352ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
5
UKAS certificate
1
Site in our directory
1
UKAS accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 5 scope lines.

UKAS certificate 29352 · 5 lines

LineMethodMatrixRange
1bs 1; ISO/IEC 17025:2017 MAC Clinical Research Finance Ltd Issue No: 001 Issue date: 13 February 2025 Laboratory Services Floor 3; IEC 17025Serum-
2-Serum
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

29352 Accredited to ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pin e Tre e s, Ch e rts ey La n e , Sta ine s -u po n-Tha me s , TW18 3 HR, UK MAC Clinical Research Finance Ltd Issue No: 001 Issue date: 13 February 2025 Testing performed at main address only Assessment Manager: AH5 Page 2 of 5 Materials/Products tested Type of test/Properties measured/Range of measurement Standard specifications/ Equipment/Techniques used HUMAN BODY FLUIDS (cont’d) Biochemistry examination activities for the purposes of clinical trials (cont’d): Documented in house method based on manufacturer’s instructions Serum/plasma (cont’d) Quantification of: (cont’d) Immunoassay using Siemens Atellica CH 93& IM 1300 LS042, LS056 Amylase (Amy_2) Creatine Kinase (CK_L) Lactate Dehydrogenase (LDLP) GGT Glucose TIBC Urate (UA) Direct HDL cholesterol (D‑HDL) Cholesterol (Chol_2) Direct LDL Cholesterol (DLDL) Transferrin Serum/plasma Quantification of: Immunoassay using Siemens Atellica CH 93& IM 1300 LS042 Ferritin (Fer) Free Triiodothyronine (FT3) Free Thyroxine (FT4) Total Triiodothyronine (T3) Total Thyroxine (T4) TSH 3-Ultra (TSH3‑UL) FSH LH Total hCG (ThCG) Folate Vitamin B12 (VB12) CA 125 CA15-3 CEA AFP Total PSA Total Vitamin D
-
3ISO/IEC 17025:2017Blood-
4-Blood
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

29352 Accredited to ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pin e Tre e s, Ch e rts ey La n e , Sta ine s -u po n-Tha me s , TW18 3 HR, UK MAC Clinical Research Finance Ltd Issue No: 001 Issue date: 13 February 2025 Testing performed at main address only Assessment Manager: AH5 Page 4 of 5 Materials/Products tested Type of test/Properties measured/Range of measurement Standard specifications/ Equipment/Techniques used HUMAN BODY FLUIDS (cont’d) Haematology examination activities for the purposes of clinical trials Documented in house method based on manufacturer’s instructions Urine Sediment analysis Siemens Atellica 1500 & Novus LS043 Quantification of: White Blood Cell Red Blood Cell Whole blood EDTA Full Blood Count and White Blood Cell differential: Using Siemens advia 560 LS052 Haemoglobin (Hb) Red blood count (RBC) Haematocrit (Hct) Mean cell volume (MCV) Mean cell haemoglobin (MCH) Mean cell haemoglobin concentration (MCHC) Red Cell Distribution Width (RDW) Platelet count (PLT) Mean Platelet Volume (MPV) White blood count (WBC) Neutrophils Lymphocytes Monocytes Eosinophils Basophils Whole blood EDTA Blood film assessment & Cell differential: Siemens hematek & microscope Romanowsky stains LS044, LS047, LS053 Plasma Coagulation PT/APTT/INR Sysmex CN3000 LS048 Whole blood EDTA White cell differential CellaVision DC-1 (digital cell imaging) LS044, LS047, LS053
-
5ISO/IEC 17025:2017Serum-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Laboratory Services, Floor 3, CityLabs 1.0, Nelson Street, Manchester, M13 9NQ, GB

53.47949, -2.24511

Open in Maps

Accreditation data refreshed from the UKAS register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the UKAS entry linked above.