Scientific Calibration
14001 Weston Parkway, Suite 106, 27513, Cary, NC, United States
Visit website- Scope lines
- 9
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 9 scope lines.
A2LA certificate 5345.01 · 9 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | Conductivity solutionsShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5345.01) Revised 11/14/2025 Page 1 of 8
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
SCIENTIFIC CALIBRATION, INC.
14001 Weston Parkway, Suite 106
Cary, NC 27513
Cody White Phone: 919-303-1212
CALIBRATION
Valid To: October 31, 2027 Certificate Number: 5345.01
In recognition of the successful completion of the A2LA evaluation process (including an assessment of
the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is
granted to this laboratory to perform the following calibrations
1, 4:
I. Chemical
Parameter/Equipment Range CMC2, 6 (±) Comments
Conductivity –
Measuring Equipment3
≈ 1 µS/cm
≈ 1413 µS/cm
≈ 200 000 µS/cm
0.67 µS/cm
15 µS/cm
1700 µS/cm
Conductivity solutions
pH – Measuring
Equipment3
≈ 4 pH
≈ 7 pH
≈ 10 pH
0.031 pH
0.022 pH
0.038 pH
pH buffer solutions
CO2 Sensors3
(0 to 5) % CO2
(>5 to 20) % CO2
0.23 % CO2
0.52 % CO2
% CO2 meter | See scope document |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5345.01) Revised 11/14/2025 Page 2 of 8
II. Dimensional
Parameter/Equipment Range CMC2 (±) Comments
Micrometers
Up to 16 in
0.000 12 in
Grade 0 gauge blocks
Calipers
Up to 16 in
0.000 42 in
Grade 0 gauge blocks
Tape Measures & Rulers
Up to 480 in
(>480 to 1200) in
0.063 in
0.089 in
Calibrated tape measure
III. Electrical/DC Low Frequency
Parameter/Equipment
Range
CMC2, 7 (±) Comments
DC Voltage – Measure
Up to 100 mV
(>0.1 to 3) V
(>3 to 30) V
(>30 to 300) V
0.02 % + 0.005 mV
0.02 % + 0.000 05 V
0.02 % + 0.0005 V
0.05 % + 0.05 V
Fluke 753
DC Current – Measure
Up to 30 mA
(>30 to 100) mA
0.015 % + 0.005 mA
0.014 % + 0.02 mA
Fluke 753
DC Resistance –
Measure
Up to 10 Ω
(>10 to 100) Ω
(>0.1 to 1) kΩ
(>1 to 10) kΩ
0.33 % + 0.05 Ω
0.05 % + 0.05 Ω
0.05 % + 0.005 kΩ
0.1 % + 0.01 kΩ
Fluke 753
Parameter/Range
Frequency CMC2, 7 (±) Comments
AC Voltage – Measure
(>0.1 to 3) V
(>3 to 30) V
(>30 to 300) V
(40 to 500) Hz
(40 to 500) Hz
(40 to 500) Hz
0.53 % + 0.002 V
0.5 % + 0.02 V
0.5 % + 0.2 V
Fluke 753 | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5345.01) Revised 11/14/2025 Page 3 of 8
Parameter/Equipment
Range CMC2 (±) Comments
Electrical Simulation of
RTD – Generate
Pt100 385
(-200 to 100) °C
(>100 to 800) °C
0.060 °C
0.15 °C
Fluke 753
Electrical Simulation of
RTD – Measure
Pt100 385
(-200 to 100) °C
(>100 to 800) °C
0.10 °C
0.32 °C
Fluke 753
Electrical Simulation of
Thermocouples –
Generate
Type J
Type K
Type T
(-210 to -100) °C
(>-100 to 800) °C
(>800 to 1200) °C
(-200 to -100) °C
(>-100 to 400) °C
(>400 to 1200) °C
(>1200 to 1372) °C
(-250 to -100) °C
(>-100 to 0) °C
(>0 to 400) °C
0.44 °C
0.40 °C
0.35 °C
0.53 °C
0.45 °C
0.39 °C
0.36 °C
1.1 °C
0.44 °C
0.49 °C
Fluke 753
Electrical Simulation of
Thermocouples –
Measure
Type J
Type K
Type T
(-210 to -100) °C
(>-100 to 800) °C
(>800 to 1200) °C
(-200 to -100) °C
(>-100 to 400) °C
(>400 to 1200) °C
(>1200 to 1372) °C
(-250 to -100) °C
(>-100 to 0) °C
(>0 to 400) °C
0.67 °C
0.45 °C
0.53 °C
0.75 °C
0.38 °C
0.53 °C
0.72 °C
1.7 °C
0.63 °C
0.49 °C
Fluke 753 | ||
| 4 | ASTM Class 3 | Nitrogen; Water | See scope document |
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5345.01) Revised 11/14/2025 Page 5 of 8
Parameter/Equipment
Range
CMC2, 6 (±) Comments
Scales, Balances &
Weighing Systems3
(cont)
10 kg
(>10 to 25) kg
(>25 to 30) kg
(>30 to 35) kg
(>35 to 45) kg
(>45 to 50) kg
(>50 to 60) kg
(>60 to 100) kg
(>100 to 200) kg
(>200 to 250) kg
1.2 g
1.4 g
1.5 g
2.6 g
2.7 g
2.8 g
4.0 g
5.6 g
11 g
14 g
Class 5, 6 weights
Note: uncertainties for
ASTM Class 5 & 6 >25
kg are the sum of
uncertainties associated
with the combination of
applied masses
Pipettes3
(0.1 to 1) µL
(1 to 20) µL
(>20 to 50) µL
(>50 to 100) µL
(>100 to 200) µL
(>200 to 500) µL
(>500 to 1000) µL
(>1 to 2) mL
(>2 to 5) mL
(>5 to 10) mL
(>10 to 25) mL
(>25 to 50) mL
(>50 to 100) mL
0.025 µL
0.37 µL
0.43 µL
0.49 µL
0.84 µL
0.93 µL
2.3 µL
5 µL
11 µL
22 µL
56 µL
120 µL
220 µL
Sartorius Cubis MP6.6S
Gravimetric – Mettler
Toledo WXTS205
Pressure & Vacuum –
Measuring Equipment3
(-13 to 300) psi
Up to 500 psi
(-30 to 30) inH
2O
(-29.5 to 0) inHg
0.078 psi
0.31 psi
0.035 inH2O
0.16 inHg
Additel 760 CP300
Fluke 750P07
Additel 760 DP30
Ashcroft DG25
Force – Measuring
Equipment – Tension &
Compression
(0.5 to 5) lbf
(230 to 2300) gf
(10 to 100) lbf
(4500 to 45 000) gf
0.015 lbf
6.8 gf
0.30 lbf
140 gf
Mark-10 MR03-5
Mark-10 MR03-100
Torque – Measuring
Equipment
(5 to 50) lbf·in
(5.8 to 58) kgf·cm
(20 to 200) lbf·in
(23 to 230) kgf·cm
0.27 lbf·in
0.31 kgf·cm
1.7 lbf·in
2.0 kgf·cm
Mark-10 MR52-50
Mark-10 MR55-200 | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5345.01) Revised 11/14/2025 Page 6 of 8
VI. Thermodynamics
Parameter/Equipment Range CMC2, 6 (±) Comments
Temperature –
Measure3
Chambers, Freezers,
Incubators, Ovens
(-196 to 0) °C
(>0 to 30) °C
(>30 to 420) °C
(-196 to -39) °C
(>-39 to 0) °C
(>0 to 232) °C
(>232 to 420) °C
(-196 to 200) °C
(>200 to 400) °C
(>400 to 1000) °C
0.065 °C
0.065 °C
0.17 °C
0.066 °C
0.029 °C
0.032 °C
0.33 °C
1.3 °C
2 °C
0.45 % + 0.5 °C
Hart 1502A Thermometer,
Isotech T100-450 probe
Additel 282, Accumac
AM1730 PRT
Fluke 54 II w/ Type T
thermocouple
Fluke 54 II w/ Type K
thermocouple
Temperature –
Measuring Equipment3
Digital & Analogue
Temperature
Measuring Equipment
-196 °C
(-180 to 50) °C
(-95 to 140) °C
(30 to 232) °C
(>232 to 400) °C
0.066 °C
0.1 °C
0.088 °C
0.16 °C
0.23 °C
Reference PRT, thermal
wells, chamber, LN2
Thermocyclers3
(0 to 95) °C
0.69 °C
Quanta Biotech TAS
System
Relative Humidity –
Measure
3
(15 to 90) % RH
1.5 % RH
Vaisala MI70 HMP 77B
Relative Humidity –
Measuring Equipment3
(15 to 90) % RH
1.5 % RH
Geo calibration humidity
chamber 2000 SP-SH,
Vaisala MI70 HMP 77B | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5345.01) Revised 11/14/2025 Page 7 of 8
VII. Time & Frequency
Parameter/Equipment
Range CMC2, 6 (±) Comments
Frequency – Measure
(1 to 110) Hz
(>0.11 to 1.1) kHz
(>1.1 to 11) kHz
(>11 to 50) kHz
0.064 Hz
0.51 Hz
0.0070 kHz
0.051 kHz
Fluke 753
Frequency – Measuring
Equipment
Up to 10.99 Hz
(11 to 109.99 Hz)
(110 to 1099.99 Hz)
(1.1 to 21.99 kHz)
(22 to 50 kHz)
0.01 Hz
0.058 Hz
0.082 Hz
0.0016 kHz
0.0031 kHz
Fluke 753
Tachometer – Measuring
Equipment
Up to 660 rpm
(660 to 6600) rpm
(6.6 to 66) krpm
(66 to 132) krpm
(132 to 3000) krpm
0.6 rpm
3.5 rpm
4.9 rpm
96 rpm
190 rpm
Fluke 753, optical diode
Centrifuges3
(9 to 10) rpm
(>10 to 60) rpm
(>60 to 600) rpm
(>600 to 6000) rpm
(>6000 to 60 000) rpm
(>60 000 to 100 000) rpm
0.0053 rpm
0.017 rpm
0.15 rpm
1.7 rpm
14 rpm
24 rpm
Monarch PLT-200
laser tachometer
Stopwatches / Timers
(30 to 72 000) s
23 ms
Counter, stopwatch,
frequency generator
__________
1 This laboratory offers commercial calibration service and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration. | ||
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5345.01) Revised 11/14/2025 Page 8 of 8
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 This scope meets A2LA’s P112 Flexible Scope Policy.
5 In the statement of CMC, the percentage given is the percentage of the reading, unless otherwise noted.
6 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
7 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a
percent or fraction of the reading plus a fixed floor specification. | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
SCIENTIFIC CALIBRATION, INC.
Cary, NC
for technical competence in the field of
Calibration
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories . This laboratory also meets R205 – Specific
Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a
defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 28th day of October 2025.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 5345.01
Valid to October 31, 2027 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.