United States

Scientific Calibration

14001 Weston Parkway, Suite 106, 27513, Cary, NC, United States

Visit website
A2LA 5345.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
9
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 9 scope lines.

A2LA certificate 5345.01 · 9 lines

LineMethodMatrixRange
1-Conductivity solutions
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5345.01) Revised 11/14/2025 Page 1 of 8 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 SCIENTIFIC CALIBRATION, INC. 14001 Weston Parkway, Suite 106 Cary, NC 27513 Cody White Phone: 919-303-1212 CALIBRATION Valid To: October 31, 2027 Certificate Number: 5345.01 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 4: I. Chemical Parameter/Equipment Range CMC2, 6 (±) Comments Conductivity – Measuring Equipment3 ≈ 1 µS/cm ≈ 1413 µS/cm ≈ 200 000 µS/cm 0.67 µS/cm 15 µS/cm 1700 µS/cm Conductivity solutions pH – Measuring Equipment3 ≈ 4 pH ≈ 7 pH ≈ 10 pH 0.031 pH 0.022 pH 0.038 pH pH buffer solutions CO2 Sensors3 (0 to 5) % CO2 (>5 to 20) % CO2 0.23 % CO2 0.52 % CO2 % CO2 meter
See scope document
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5345.01) Revised 11/14/2025 Page 2 of 8 II. Dimensional Parameter/Equipment Range CMC2 (±) Comments Micrometers Up to 16 in 0.000 12 in Grade 0 gauge blocks Calipers Up to 16 in 0.000 42 in Grade 0 gauge blocks Tape Measures & Rulers Up to 480 in (>480 to 1200) in 0.063 in 0.089 in Calibrated tape measure III. Electrical/DC Low Frequency Parameter/Equipment Range CMC2, 7 (±) Comments DC Voltage – Measure Up to 100 mV (>0.1 to 3) V (>3 to 30) V (>30 to 300) V 0.02 % + 0.005 mV 0.02 % + 0.000 05 V 0.02 % + 0.0005 V 0.05 % + 0.05 V Fluke 753 DC Current – Measure Up to 30 mA (>30 to 100) mA 0.015 % + 0.005 mA 0.014 % + 0.02 mA Fluke 753 DC Resistance – Measure Up to 10 Ω (>10 to 100) Ω (>0.1 to 1) kΩ (>1 to 10) kΩ 0.33 % + 0.05 Ω 0.05 % + 0.05 Ω 0.05 % + 0.005 kΩ 0.1 % + 0.01 kΩ Fluke 753 Parameter/Range Frequency CMC2, 7 (±) Comments AC Voltage – Measure (>0.1 to 3) V (>3 to 30) V (>30 to 300) V (40 to 500) Hz (40 to 500) Hz (40 to 500) Hz 0.53 % + 0.002 V 0.5 % + 0.02 V 0.5 % + 0.2 V Fluke 753
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5345.01) Revised 11/14/2025 Page 3 of 8 Parameter/Equipment Range CMC2 (±) Comments Electrical Simulation of RTD – Generate Pt100 385 (-200 to 100) °C (>100 to 800) °C 0.060 °C 0.15 °C Fluke 753 Electrical Simulation of RTD – Measure Pt100 385 (-200 to 100) °C (>100 to 800) °C 0.10 °C 0.32 °C Fluke 753 Electrical Simulation of Thermocouples – Generate Type J Type K Type T (-210 to -100) °C (>-100 to 800) °C (>800 to 1200) °C (-200 to -100) °C (>-100 to 400) °C (>400 to 1200) °C (>1200 to 1372) °C (-250 to -100) °C (>-100 to 0) °C (>0 to 400) °C 0.44 °C 0.40 °C 0.35 °C 0.53 °C 0.45 °C 0.39 °C 0.36 °C 1.1 °C 0.44 °C 0.49 °C Fluke 753 Electrical Simulation of Thermocouples – Measure Type J Type K Type T (-210 to -100) °C (>-100 to 800) °C (>800 to 1200) °C (-200 to -100) °C (>-100 to 400) °C (>400 to 1200) °C (>1200 to 1372) °C (-250 to -100) °C (>-100 to 0) °C (>0 to 400) °C 0.67 °C 0.45 °C 0.53 °C 0.75 °C 0.38 °C 0.53 °C 0.72 °C 1.7 °C 0.63 °C 0.49 °C Fluke 753
4ASTM Class 3Nitrogen; WaterSee scope document
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5345.01) Revised 11/14/2025 Page 5 of 8 Parameter/Equipment Range CMC2, 6 (±) Comments Scales, Balances & Weighing Systems3 (cont) 10 kg (>10 to 25) kg (>25 to 30) kg (>30 to 35) kg (>35 to 45) kg (>45 to 50) kg (>50 to 60) kg (>60 to 100) kg (>100 to 200) kg (>200 to 250) kg 1.2 g 1.4 g 1.5 g 2.6 g 2.7 g 2.8 g 4.0 g 5.6 g 11 g 14 g Class 5, 6 weights Note: uncertainties for ASTM Class 5 & 6 >25 kg are the sum of uncertainties associated with the combination of applied masses Pipettes3 (0.1 to 1) µL (1 to 20) µL (>20 to 50) µL (>50 to 100) µL (>100 to 200) µL (>200 to 500) µL (>500 to 1000) µL (>1 to 2) mL (>2 to 5) mL (>5 to 10) mL (>10 to 25) mL (>25 to 50) mL (>50 to 100) mL 0.025 µL 0.37 µL 0.43 µL 0.49 µL 0.84 µL 0.93 µL 2.3 µL 5 µL 11 µL 22 µL 56 µL 120 µL 220 µL Sartorius Cubis MP6.6S Gravimetric – Mettler Toledo WXTS205 Pressure & Vacuum – Measuring Equipment3 (-13 to 300) psi Up to 500 psi (-30 to 30) inH 2O (-29.5 to 0) inHg 0.078 psi 0.31 psi 0.035 inH2O 0.16 inHg Additel 760 CP300 Fluke 750P07 Additel 760 DP30 Ashcroft DG25 Force – Measuring Equipment – Tension & Compression (0.5 to 5) lbf (230 to 2300) gf (10 to 100) lbf (4500 to 45 000) gf 0.015 lbf 6.8 gf 0.30 lbf 140 gf Mark-10 MR03-5 Mark-10 MR03-100 Torque – Measuring Equipment (5 to 50) lbf·in (5.8 to 58) kgf·cm (20 to 200) lbf·in (23 to 230) kgf·cm 0.27 lbf·in 0.31 kgf·cm 1.7 lbf·in 2.0 kgf·cm Mark-10 MR52-50 Mark-10 MR55-200
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5345.01) Revised 11/14/2025 Page 6 of 8 VI. Thermodynamics Parameter/Equipment Range CMC2, 6 (±) Comments Temperature – Measure3 Chambers, Freezers, Incubators, Ovens (-196 to 0) °C (>0 to 30) °C (>30 to 420) °C (-196 to -39) °C (>-39 to 0) °C (>0 to 232) °C (>232 to 420) °C (-196 to 200) °C (>200 to 400) °C (>400 to 1000) °C 0.065 °C 0.065 °C 0.17 °C 0.066 °C 0.029 °C 0.032 °C 0.33 °C 1.3 °C 2 °C 0.45 % + 0.5 °C Hart 1502A Thermometer, Isotech T100-450 probe Additel 282, Accumac AM1730 PRT Fluke 54 II w/ Type T thermocouple Fluke 54 II w/ Type K thermocouple Temperature – Measuring Equipment3 Digital & Analogue Temperature Measuring Equipment -196 °C (-180 to 50) °C (-95 to 140) °C (30 to 232) °C (>232 to 400) °C 0.066 °C 0.1 °C 0.088 °C 0.16 °C 0.23 °C Reference PRT, thermal wells, chamber, LN2 Thermocyclers3 (0 to 95) °C 0.69 °C Quanta Biotech TAS System Relative Humidity – Measure 3 (15 to 90) % RH 1.5 % RH Vaisala MI70 HMP 77B Relative Humidity – Measuring Equipment3 (15 to 90) % RH 1.5 % RH Geo calibration humidity chamber 2000 SP-SH, Vaisala MI70 HMP 77B
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5345.01) Revised 11/14/2025 Page 7 of 8 VII. Time & Frequency Parameter/Equipment Range CMC2, 6 (±) Comments Frequency – Measure (1 to 110) Hz (>0.11 to 1.1) kHz (>1.1 to 11) kHz (>11 to 50) kHz 0.064 Hz 0.51 Hz 0.0070 kHz 0.051 kHz Fluke 753 Frequency – Measuring Equipment Up to 10.99 Hz (11 to 109.99 Hz) (110 to 1099.99 Hz) (1.1 to 21.99 kHz) (22 to 50 kHz) 0.01 Hz 0.058 Hz 0.082 Hz 0.0016 kHz 0.0031 kHz Fluke 753 Tachometer – Measuring Equipment Up to 660 rpm (660 to 6600) rpm (6.6 to 66) krpm (66 to 132) krpm (132 to 3000) krpm 0.6 rpm 3.5 rpm 4.9 rpm 96 rpm 190 rpm Fluke 753, optical diode Centrifuges3 (9 to 10) rpm (>10 to 60) rpm (>60 to 600) rpm (>600 to 6000) rpm (>6000 to 60 000) rpm (>60 000 to 100 000) rpm 0.0053 rpm 0.017 rpm 0.15 rpm 1.7 rpm 14 rpm 24 rpm Monarch PLT-200 laser tachometer Stopwatches / Timers (30 to 72 000) s 23 ms Counter, stopwatch, frequency generator __________ 1 This laboratory offers commercial calibration service and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration.
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5345.01) Revised 11/14/2025 Page 8 of 8 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 This scope meets A2LA’s P112 Flexible Scope Policy. 5 In the statement of CMC, the percentage given is the percentage of the reading, unless otherwise noted. 6 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 7 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification.
9

Extracted from the scope document; tables may not line up. View scope for the original.

For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation. Accredited Laboratory A2LA has accredited SCIENTIFIC CALIBRATION, INC. Cary, NC for technical competence in the field of Calibration This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories . This laboratory also meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 28th day of October 2025. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 5345.01 Valid to October 31, 2027

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

14001 Weston Parkway, Suite 106, Cary, NC, 27513, US

35.78829, -78.78121

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.