Veolia Energia Warszawa
ul. Siemieńskiego 4, 02-106, Warszawa, Poland
- Accredited standards
- 29
- PCA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the PCA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 29 standard numbers and the 20 official names we hold. When no standard matches, it searches the method text of every scope line.
ISO20
ISO 527-1Plastics - Determination of tensile properties - Part 1: General principles
ISO 844Rigid cellular plastics - Determination of compressive properties
ISO 845Cellular plastics and rubbers - Determination of apparent density
ISO 1798Flexible cellular polymeric materials - Determination of tensile strength and elongation at break
ISO 1856Flexible cellular polymeric materials - Determination of compression set
ISO 1923Cellular plastics and rubbers - Determination of linear dimensions
ISO 2896Rigid cellular plastics - Determination of water absorption
ISO 3386-1Polymeric materials, cellular flexible - Determination of stress-strain characteristics in compression - Part 1: Low-density materials
ISO 4590Rigid cellular plastics - Determination of the volume percentage of open cells and of closed cells
ISO 6259-1Thermoplastics pipes - Determination of tensile properties - Part 1: General test method
ISO 6259-3Thermoplastics pipes - Determination of tensile properties - Part 3: Polyolefin pipes
ISO 8301Thermal insulation - Determination of steady-state thermal resistance and related properties - Heat flow meter apparatus
Show all 20
ISO 8497Thermal insulation - Determination of steady-state thermal transmission properties of thermal insulation for circular pipes
ISO 10147Pipes and fittings made of crosslinked polyethylene (PE-X) - Estimation of the degree of crosslinking by determination of the gel content
ISO 12628Thermal insulating products for building equipment and industrial installations - Determination of dimensions, squareness and linearity of preformed pipe insulation
ISO 12667Commercial vehicles and buses - Cross-tooth propeller shaft flanges, type T
ISO 16770Plastics - Determination of environmental stress cracking (ESC) of polyethylene - Full-notch creep test (FNCT)
ISO 18096Thermal insulating products for building equipment and industrial installations - Determination of maximum service temperature for preformed pipe insulation
ISO 18098Thermal insulating products for building equipment and industrial installations - Determination of the apparent density of preformed pipe insulation
ISO 29469Thermal insulating products for building applications - Determination of compression behaviour
EN9
EN 253
EN 448
EN 489-1
EN 579
EN 1602
EN 12814-1
EN 13941-1
EN 15698-1
EN 17415-1
PN-EN ISO 8497; PN-ISO 8301; PN-EN ISO 845; PN-EN 1602; PN-EN ISO 18098; PN-EN ISO 29469; PN-EN ISO 844; PN-EN ISO 4590; PN-EN 253; EN 253; PB-01; PN-EN ISO 3386-1; PN-EN 13941-1; PN-EN ISO 1856; ISO 1856; PN-EN 13941-1; PN-EN ISO 1923; PN-93/C-89084; ISO 2896; PN-EN 12814-1; ISO 16770; PN-EN ISO 527-1; IB-SB-19-1; IB-SB-19-2
PN-EN ISO 10147:2013-06; PN-EN 579:2001; PN-EN ISO 6259-1:2015-05; PN-EN ISO 6259-3:2015-08; PN-EN ISO 12628:2023-02; PN-EN ISO 18096:2023-02; PN-EN ISO 29469:2023-05; PN-EN ISO 12667:2002; PN-EN ISO 1798:2009; PN-EN 253+A2:2015-12
PN-EN 253; EN 253
PN-EN 448; EN 448
PN-EN 489-1; EN 489-1; PN-EN 17415-1; EN 17415-1
PN-EN 15698-1; EN 15698-1
Read from the PCA scope document we downloaded on 2026-03-13. Register refreshed 2026-11-06.
Scope as published by PCA
7 lines
ISO/IEC 17025
ActiveAB 414
The scope document we hold says it is valid until 2027-02-11.
Accredited scope, certificate AB 414
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | structural materials and products; plastic productsShow page textExtracted from the scope document; tables may not line up. View scope for the original. PCA Zakres akredytacji Nr AB 414
Scope of accreditation No. AB 414
ZAKRES AKREDYTACJI
LABORATORIUM BADAWCZEGO
SCOPE OF ACCREDITATION FOR TESTING LABORATORY
Nr/No. AB 414
wydany przez / issued by
POLSKIE CENTRUM AKREDYTACJI
01-382 Warszawa, ul. Szczotkarska 42
Wydanie/Issue 24 z/of 18.12.2025
KIEROWNIK DZIAŁU AKREDYTACJI
BADAŃ MECHANICZNYCH I FIZYCZNYCH
MARIA SZAFRAN
Niniejszy dokument jest załącznikiem do Certyfikatu Akredytacji Nr AB 414 z dnia 23.12.2019 r.
Cykl akredytacji od 12.01.2023 r. do 11.02.2027 r.
Status akredytacji oraz aktualność zakresu akredytacji można potwierdzić na stronie internetowej PCA www.pca.gov.pl
This document is an annex to accreditation certificate No. AB 414 of 23.12.2019
Accreditation cycle from 12.01.2023 to 11.02.2027
The status of accreditation and validity of the scope of accreditation can be confirmed at PCA website www.pca.gov.pl
Wydanie nr / Issue No. 24, 18.12.2025 1/8
Nazwa i adres / Name and address
VEOLIA ENERGIA WARSZAWA S.A.
ul. Batorego 2
02-591 Warszawa
LABORATORIUM BADAWCZE
ul. Siemieńskiego 4
02-106 Warszawa
Kod identyfikacyjny /
Identification code *) Dziedzina i przedmiot badań / Field of testing and item:
- J/8; J/21
- N/8; N/21
- C/21
- Badania mechaniczne wyrobów i materiałów konstrukcyjnych, wyrobów z tworzyw sztucznych /
Mechanical tests of structural materials and products, plastic products
- Badania właściwości fizycznych wyrobów i materiałów konstrukcyjnych, wyrobów z tworzyw sztucznych
/ Physical properties tests of structural materials and products, plastic products
- Badania chemiczne wyrobów z tworzyw sztucznych / Chemical tests of plastic products
Wersja strony/Page version: A
*) Kod identyfikacyjny zgodnie z załącznikiem do dokumentu DAB -07 dostępnym na stronie internetowej www.pca.gov.pl /
The identification code according to the Annex to document DAB-07, available at PCA website www.pca.gov.pl
AB 414 | - |
| 2 | PN-EN 253; EN 253 | Rury preizolowane pojedyncze do budowy wodnych sieci ciepłowniczych | to 10 mm |
| 3 | PN-EN 489-1; EN 489-1; PN-EN 17415-1; EN 17415-1 | Zespół złącza preizolowanego (rury preizolowane pojedyncze i podwójne); Rury preizolowane pojedyncze do budowy wodnych sieci chłodu systemowego | to 10 kN |
| 4 | PN-EN 448; EN 448 | Kształtki preizolowane | to 10 kN |
| 5 | PN-EN 15698-1; EN 15698-1 | Rury preizolowane podwójne do budowy wodnych sieci ciepłowniczych | to 2 mm |
| 6 | PN-EN ISO 8497; PN-ISO 8301; PN-EN ISO 845; PN-EN 1602; PN-EN ISO 18098; PN-EN ISO 29469; PN-EN ISO 844; PN-EN ISO 4590; PN-EN 253; EN 253; PB-01; PN-EN ISO 3386-1; PN-EN 13941-1; PN-EN ISO 1856; ISO 1856; PN-EN 13941-1; PN-EN ISO 1923; PN-93/C-89084; ISO 2896; PN-EN 12814-1; ISO 16770; PN-EN ISO 527-1; IB-SB-19-1; IB-SB-19-2 | Wyroby włókniste; Tworzywa sztuczne porowate; Tworzywa sztuczne termoplastyczne; Kaptur końcowy termokurczliwy | to 0.08 W/mK |
| 7 | PN-EN ISO 10147:2013-06; PN-EN 579:2001; PN-EN ISO 6259-1:2015-05; PN-EN ISO 6259-3:2015-08; PN-EN ISO 12628:2023-02; PN-EN ISO 18096:2023-02; PN-EN ISO 29469:2023-05; PN-EN ISO 12667:2002; PN-EN ISO 1798:2009; PN-EN 253+A2:2015-12 | Tworzywa sztuczne termoplastyczne; Wyroby włókniste; Tworzywa sztuczne porowate; Rury preizolowane pojedyncze do budowy wodnych sieci ciepłowniczych | to 0.08 W/mK |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the PCA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the PCA entry linked above.