Registers refreshed 2026-11-08.See refresh dates
Italy

Arcadia Consulting

via Ossola, 6, 21015, Lonate Pozzolo, Italy

Visit website
ACCREDIA 01348ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
10
ACCREDIA certificate
1
Site in our directory
1
ACCREDIA accredited scope

What this lab is accredited for

Our reading of the ACCREDIA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 10 standard numbers and the 9 official names we hold. When no standard matches, it searches the method text of every scope line.

APAT CNR IRSA 2060 Man 29 2003pH
APAT CNR IRSA 4030 A1 Man 29 2003
EN 13284-1Stationary source emissions - Determination of low range mass concentration of dust - Part 1: Manual gravimetric method
EN 13657Characterization of waste - Digestion for subsequent determination of aqua regia soluble portion of elements
EN 15934Sludge, treated biowaste, soil and waste - Calculation of dry matter fraction after determination of dry residue or water contentSome methods

Limits written next to it

UNI EN 15934:2012 - solo/only Met A Gravimetria

Some methods. Written next to it on line 2 of ACCREDIA certificate 01348.

UNI EN 15934:2012 - solo/only Met.

Some methods. Written next to it on line 2 of ACCREDIA certificate 01348.

ISO 7027-1Water quality - Determination of turbidity - Part 1: Quantitative methods
ISO 9377-2Water quality - Determination of hydrocarbon oil index - Part 2: Method using solvent extraction and gas chromatography
ISO 11885Water quality - Determination of selected elements by inductively coupled plasma optical emission spectrometry (ICP-OES)
ISO 15705Water quality - Determination of the chemical oxygen demand index (ST-COD) - Small-scale sealed-tube method
ISO 16703Soil quality - Determination of content of hydrocarbon in the range C10 to C40 by gas chromatography

Read from the scope as published by ACCREDIA. Register refreshed 2026-11-06.

Scope as published by ACCREDIA

3 lines
ACCREDIA

ISO/IEC 17025

Active

01348

View scope

Accredited scope, certificate 01348

LineMethodMatrixRange
1UNI CEI EN ISO/IEC 17025:2018; APAT CNR IRSA 4030 A1 Man 29 2003; APAT CNR IRSA 2060 Man 29 2003; APAT CNR IRSA 2030 Man 29 2003; UNI EN ISO 9377-2:2002; UNI EN ISO 7027-1:2016; APAT CNR IRSA 2020 A Man 29 2003; UNI EN ISO 11885:2009; ISO 15705:2002Waste waterto 12.5 pH
2UNI CEI EN ISO/IEC 17025:2018; UNI EN 13657:2004; UNI EN ISO 11885:2009; UNI EN 15934:2012; DM 13/09/1999 SO n 185 GU n 248 21/10/1999 Met II.1; UNI EN 13284-1:2017; UNI EN ISO 16703:2011Soil1 to 1000 g/Kg
3UNI CEI EN ISO/IEC 17025:2018; APAT CNR IRSA 2060 Man 29 2003; APAT CNR IRSA 2030 Man 29 2003Acque destinate al consumo umano; Drinking waters; Acque di piscina; Swimming pool waters; Acque di scarico; Waste waters; Acque naturali; Natural waters; Acque sotterranee; Ground waters; Acque superficiali; Surface waters4 to 10 pH

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

via Ossola, 6, Lonate Pozzolo, 21015, IT

45.59677, 8.75473

Open in Maps

Accreditation data refreshed from the ACCREDIA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ACCREDIA entry linked above.