Gulf Coast Calibration

10416 Spencer Highway, 77571, La Porte, TX, United States

Visit website
A2LA 3898.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
9
A2LA certificate
1
Sites in our directory
2
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 9 scope lines.

A2LA certificate 3898.01 · 9 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017--
2-Gage blocks; Indicators
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3898.01) Revised 07/24/2026 Page 2 of 8 Parameter/Equipment Range CMC2, 10 (±) Comments Height Gage/Height Master Up to 40 in (3.7 + 15L) µin Gage blocks Indicators Up to 2 in 31 µin Gage blocks II. Electrical – DC / Low Frequency Parameter/Equipment Range CMC2, 4, 13 (±) Comments DC Voltage – Generate3 (0 to 329.9999) mV (0 to 3.299 999) V (0 to 32.999 99) V (30 to 329.9999) V (100 to 1000) V 15 µV /V + 1 µV 9 µV /V + 2 µV 10 µV /V + 20 µV 15 µV /V + 150 µV 15 µV /V + 1500 µV Fluke 5520A DC Current – Generate3 (0 to 329.999) µA (0 to 3.299 99) mA (0 to 32.9999) mA (0 to 329.999) mA (0 to 1.099 99) A (1.1 to 2.999 99) A (0 to 10.9999) A (11 to 20.5) A 120 µA /A + 0.02 µA 80 µA /A + 0.05 µA 80 µA /A + 0.25 µA 80 µA /A + 2.5 µA 160 µA /A + 40 µA 300 µA /A + 40 µA 380 µA /A + 500 µA 800 µA /A + 750 µA Fluke 5520A Resistance – Source Fixed Points 3 (0 to 10.9999) Ω (11 to 32.9999) Ω (33 to 109.9999) Ω (110 to 329.9999) Ω 330 Ω to 1.099 999 kΩ (1.1 to 3.299 999) kΩ (3.3 to 10.999 99) kΩ (11 to 32.999 99) kΩ (33 to 109.9999) kΩ (110 to 329.9999) kΩ 330 kΩ to 1.099 999 MΩ (1.1 to 3.299 999) MΩ (3.3 to 10.999 99) MΩ (11 to 32.999 99) MΩ (33 to 109.9999) MΩ (110 to 329.9999) MΩ (330 to 1100) MΩ 35 µΩ/Ω + 0.001 Ω 25 µΩ/Ω + 0.0015 Ω 22 µΩ/Ω + 0.0014 Ω 22 µΩ/Ω + 0.002 Ω 22 µΩ/Ω + 0.002 Ω 22 µΩ/ Ω + 0.02 Ω 22 µΩ/Ω + 0.02 Ω 22 µΩ/Ω + 0.2 Ω 22 µΩ/Ω + 0.2 Ω 25 µΩ/Ω + 2 Ω 25 µΩ/Ω + 2 Ω 40 µΩ/Ω + 30 Ω 110 µΩ/Ω + 50 Ω 200 µΩ/Ω + 2500 Ω 400 µΩ/Ω + 3000 Ω 2500 µΩ/Ω + 100 kΩ 12 000 µΩ/Ω + 500 kΩ Fluke 5520A
-
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3898.01) Revised 07/24/2026 Page 3 of 8 Parameter/Range Equipment CMC2, 4, 13 (±) Comments AC Voltage, Sine Wave – Generate3 (1.0 to 32.999) mV (33 to 329.999) mV (0.33 to 3.299 99) V (3.3 to 32.9999) V (33 to 329.999) V (330 to 1020) V (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz 45 Hz to 1 kHz (1 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 600 µV/V + 6 µV 120 µV/V + 6 µV 160 µV/V + 6 µV 800 µV/V + 6 µV 3000 µV/V + 12 µV 6000 µV/V + 50 µV 250 µV/V + 8 µV 140 µV/V + 8 µV 150 µV/V + 8 µV 300 µV/V + 8 µV 600 µV/V + 32 µV 1600 µV/V + 70 µV 250 µV/V + 50 µV 140 µV/V + 60 µV 160 µV/V + 60 µV 250 µV/V + 50 µV 550 µV/V + 130 µV 2000 µV/V + 600 µV 250 µV/V + 650 µV 130 µV/V + 600 µV 220 µV/V + 600 µV 300 µV/V + 600 µV 750 µV/V + 1600 µV 150 µV /V + 2 mV 160 µV /V + 6 mV 220 µV /V + 6 mV 240 µV /V + 6 mV 1600 µV /V + 50 mV 250 µV /V + 10 mV 200 µV /V + 10 mV 250 µV /V + 10 mV Fluke 5520A Parameter/Equipment Range CMC2, 4, 13 (±) Comments Capacitance – Generate3 (0.19 to 0.3999) nF (0.4 to 1.0999) nF (1.1 to 3.2999) nF (3.3 to 10.9999) nF (11 to 32.9999) nF (33 to 109.999) nF 0.38 % output + 0.01 nF 0.38 % output + 0.01 nF 0.38 % output + 0.01 nF 0.19 % output + 0.01 nF 0.19 % output + 0.1 nF 0.19 % output + 0.1 nF Fluke 5520A
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3898.01) Revised 07/24/2026 Page 4 of 8 Parameter/Equipment Range CMC2, 4, 13 (±) Comments Capacitance – Generate3 (cont) (110 to 329.999) nF (0.33 to 1.099 99) µF (1.1 to 3.299 99) µF (3.3 to 10.9999) µF (11 to 32.9999) µF (33 to 109.999) µF (110 to 329.999) µF (0.33 to 1.099 99) mF (1.1 to 3.2999) mF (3.3 to 10.9999) mF (11 to 32.9999) mF (33 to 110) mF 0.19 % output + 0.3 nF 0.19 % output + 1 nF 0.19 % output + 3 nF 0.19 % output + 10 nF 0.30 % output + 30 nF 0.34 % output + 100 nF 0.34 % output + 300 nF 0.34 % output + 1 µF 0.34 % output + 3 µF 0.34 % output + 10 µF 0.7 % output + 30 µF 1.0 % output + 100 µF Fluke 5520A DC Voltage – Measure5 100 mV 1 V 10 V 100 V 1000 V 0.006 mV 0.000 016 V 0.000 11 V 0.0016 V 0.016 V HP 34401A DC Current – Measure5 10 mA 100 mA 10 A 3 A 0.002 mA 0.022 mA 0.0003 A 0.0026 A HP 34401A Resistance – Measure5 100 Ω 1.0 kΩ 10 kΩ 100 kΩ 1 MΩ 10 MΩ 100 MΩ 0.0060 Ω 0.000 014 kΩ 0.000 14 kΩ 0.0014 kΩ 0.000 024 MΩ 0.000 50 MΩ 0.080 MΩ HP 34401A Parameter/Range Frequency CMC2, 4, 13 (±) Comments AC Current, Sine Wave – Generate3 (29 to 329.99) µA (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz 0.16 % output + 0.1 µA 0.12 % output + 0.1 µA 0.1 % output + 0.1 µA 0.25 % output + 0.15 µA 0.6 % output + 0.2 µA 1.2 % output + 0.4 µA Fluke 5520A
5-AC Current, Sine Wave
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3898.01) Revised 07/24/2026 Page 5 of 8 Parameter/Range Frequency CMC2, 4, 13 (±) Comments AC Current, Sine Wave – Generate3 (cont) (0.33 to 3.2999) mA (3.3 to 32.999) mA (33 to 329.99) mA (0.33 to 1.099 99) A (1.1 to 2.999 99) A (3 to 10.9999) A (11 to 20.5) A (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (45 to 100) Hz 100 Hz to 1 kHz (1 to 5) kHz (45 to 100) Hz 100 Hz to 1 kHz (1 to 5) kHz 0.16 % output + 0.15 µA 0.1 % output + 0.15 µA 0.08 % output + 0.15 µA 0.16 % output + 0.2 µA 0.4 % output + 0.3 µA 0.8 % output + 0.6 µA 0.15 % output + 2 µA 0.075 % output + 2 µA 0.035 % output + 2 µA 0.065 % output + 2 µA 0.16 % output + 3 µA 0.32 % output + 4 µA 0.15 % output + 20 µA 0.075 % output + 20 µA 0.035 % output + 20 µA 0.08 % output + 50 µA 0.16 % output + 100 µA 0.32 % output + 200 µA 0.15 % output + 100 µA 0.036 % output + 100 µA 0.5 % output + 1000 µA 2.0 % output + 5000 µA 0.15 % output + 100 µA 0.05 % output + 100 µA 0.5 % output + 1000 µA 2.0 % output + 5000 µA 0.05 % output + 2000 µA 0.08 % output + 2000 µA 2.5 % output + 2000 µA 0.1 % output + 5000 µA 0.13 % output + 5000 µA 2.5 % output + 5000 µA Fluke 5520A
-
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3898.01) Revised 07/24/2026 Page 6 of 8 Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage, Sine Wave – Measure5, 6, 7 100 mV (1 to 750) V (3 to 5) Hz (5 to 10) Hz (10 to 20) kHz (20 to 50 kHz (50 to 100) kHz (100 to 300) kHz (3 to 5) Hz (5 to 10) Hz 10 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 0.06 mV 0.06 mV 0.06 mV 0.10 mV 0.16 mV 1.0 mV 0.32 V 0.31 V 0.30 V 0.60 V 1.2 V 7.6 V HP 34401A AC Current, Sine Wave – Measure 5, 6, 7 1.0 A 3.0 A (3 to 5) Hz (5 to 10) Hz 10 Hz to 5 kHz (3 to 5) Hz (5 to 10) Hz 10 Hz to 5kHz 0.0008 A 0.0008 A 0.0008 A 0.026 A 0.011 A 0.0066 A HP 34401A Parameter/Equipment Range CMC2, 13 (±) Comments Electrical Calibration of Thermocouple Indicators Type J Type K (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 1000) °C (1000 to 1372) °C 0.20 °C 0.12 °C 0.10 °C 0.13 °C 0.18 °C 0.25 °C 0.14 °C 0.12 °C 0.19 °C 0.30 °C Fluke 5520A
7-RTDs
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3898.01) Revised 07/24/2026 Page 7 of 8 Parameter/Range Range CMC2, 13 (±) Comments Electrical Calibration of RTDs Pt 385, 100 Ω (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (630 to 800) °C 0.04 °C 0.05 °C 0.07 °C 0.08 °C 0.09 °C 0.10 °C 0.21 °C Fluke 5520A III. Mechanical Parameter/Equipment Range CMC2, 9, 12 (±) Comments Pressure – Measuring Equipment (-15 to 1500) psi (20 to 20 000) psi (20 000 to 60 000) psi 0.30 psi 0.0086 % 69 psi Mensor CPC6000 Mensor CPB5800 Additel ADT680W Torque – Measure (250 to 2500) ft·lb 3.2 ft·lb AKO torque sensors V. Time and Frequency Parameter/Equipment Range CMC2, 12 (±) Comments Frequency – Measure5, 8 100 mV to 750 V (3 to 5) Hz (5 to 10) Hz (10 to 40) Hz 40 Hz to 300 kHz 0.006 Hz 0.005 Hz 0.006 Hz 0.0048 Hz HP 34401A Frequency – Measuring Equipment13 (0.01 to 119.99) Hz (120.0 to 1199.9) Hz (1.20 to 11.999) kHz (12.00 to 119.99) kHz (120.0 to 1199.9) kHz (1.20 to 2.0) MHz 2.5 µHz/Hz + 5 µHz Fluke 5520A ________________________________________________________________
See scope document
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3898.01) Revised 07/24/2026 Page 8 of 8 1 This laboratory offers commercial calibration service and Field Calibration Service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC uncertainty due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for these calibrations. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMC are expressed as either a specific value that covers the full range or as a percentage or fraction of the reading plus a fixed floor specification. 5 This spec. is valid over the temperature range of 18 °C to 28 °C after a 1 hour warm up time. 6 This spec. is valid for ac sinewave signals > 5% of the range. For inputs from 1 % to 5 % of range and < 50 kHz add an additional error of 0.1 % of range and for 50 kHz to 100 kHz add 0.13 % of range. 7 This spec. is valid with NPLC set to 10 or higher. 8 This spec is after a delay of 1 second minimum. 9 In the statement of CMC, percentages are percentage of reading, unless otherwise indicated. 10 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches. 11 This scope meets A2LA’s P112 Flexible Scope Policy. 12 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 13 The CMC values listed for these parameters do not include a contribution from the Unit Under Test.
9ISO/IEC 17025:2017--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

10416 Spencer Highway, La Porte, TX, 77571, US

29.66451, -95.07011

Open in Maps

Other Locations

1 other site in this organization

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.