Gulf Coast Calibration
10416 Spencer Highway, 77571, La Porte, TX, United States
Visit website- Scope lines
- 9
- A2LA certificate
- 1
- Sites in our directory
- 2
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 9 scope lines.
A2LA certificate 3898.01 · 9 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017 | - | - |
| 2 | - | Gage blocks; IndicatorsShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3898.01) Revised 07/24/2026 Page 2 of 8
Parameter/Equipment
Range
CMC2, 10 (±)
Comments
Height Gage/Height
Master
Up to 40 in
(3.7 + 15L) µin
Gage blocks
Indicators
Up to 2 in
31 µin
Gage blocks
II. Electrical – DC / Low Frequency
Parameter/Equipment
Range
CMC2, 4, 13 (±)
Comments
DC Voltage – Generate3
(0 to 329.9999) mV
(0 to 3.299 999) V
(0 to 32.999 99) V
(30 to 329.9999) V
(100 to 1000) V
15 µV /V + 1 µV
9 µV /V + 2 µV
10 µV /V + 20 µV
15 µV /V + 150 µV
15 µV /V + 1500 µV
Fluke 5520A
DC Current – Generate3
(0 to 329.999) µA
(0 to 3.299 99) mA
(0 to 32.9999) mA
(0 to 329.999) mA
(0 to 1.099 99) A
(1.1 to 2.999 99) A
(0 to 10.9999) A
(11 to 20.5) A
120 µA /A + 0.02 µA
80 µA /A + 0.05 µA
80 µA /A + 0.25 µA
80 µA /A + 2.5 µA
160 µA /A + 40 µA
300 µA /A + 40 µA
380 µA /A + 500 µA
800 µA /A + 750 µA
Fluke 5520A
Resistance – Source Fixed
Points
3
(0 to 10.9999) Ω
(11 to 32.9999) Ω
(33 to 109.9999) Ω
(110 to 329.9999) Ω
330 Ω to 1.099 999 kΩ
(1.1 to 3.299 999) kΩ
(3.3 to 10.999 99) kΩ
(11 to 32.999 99) kΩ
(33 to 109.9999) kΩ
(110 to 329.9999) kΩ
330 kΩ to 1.099 999 MΩ
(1.1 to 3.299 999) MΩ
(3.3 to 10.999 99) MΩ
(11 to 32.999 99) MΩ
(33 to 109.9999) MΩ
(110 to 329.9999) MΩ
(330 to 1100) MΩ
35 µΩ/Ω + 0.001 Ω
25 µΩ/Ω + 0.0015 Ω
22 µΩ/Ω + 0.0014 Ω
22 µΩ/Ω + 0.002 Ω
22 µΩ/Ω + 0.002 Ω
22 µΩ/ Ω + 0.02 Ω
22 µΩ/Ω + 0.02 Ω
22 µΩ/Ω + 0.2 Ω
22 µΩ/Ω + 0.2 Ω
25 µΩ/Ω + 2 Ω
25 µΩ/Ω + 2 Ω
40 µΩ/Ω + 30 Ω
110 µΩ/Ω + 50 Ω
200 µΩ/Ω + 2500 Ω
400 µΩ/Ω + 3000 Ω
2500 µΩ/Ω + 100 kΩ
12 000 µΩ/Ω + 500 kΩ
Fluke 5520A | - |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3898.01) Revised 07/24/2026 Page 3 of 8
Parameter/Range
Equipment
CMC2, 4, 13 (±)
Comments
AC Voltage, Sine Wave –
Generate3
(1.0 to 32.999) mV
(33 to 329.999) mV
(0.33 to 3.299 99) V
(3.3 to 32.9999) V
(33 to 329.999) V
(330 to 1020) V
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
45 Hz to 1 kHz
(1 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
600 µV/V + 6 µV
120 µV/V + 6 µV
160 µV/V + 6 µV
800 µV/V + 6 µV
3000 µV/V + 12 µV
6000 µV/V + 50 µV
250 µV/V + 8 µV
140 µV/V + 8 µV
150 µV/V + 8 µV
300 µV/V + 8 µV
600 µV/V + 32 µV
1600 µV/V + 70 µV
250 µV/V + 50 µV
140 µV/V + 60 µV
160 µV/V + 60 µV
250 µV/V + 50 µV
550 µV/V + 130 µV
2000 µV/V + 600 µV
250 µV/V + 650 µV
130 µV/V + 600 µV
220 µV/V + 600 µV
300 µV/V + 600 µV
750 µV/V + 1600 µV
150 µV /V + 2 mV
160 µV /V + 6 mV
220 µV /V + 6 mV
240 µV /V + 6 mV
1600 µV /V + 50 mV
250 µV /V + 10 mV
200 µV /V + 10 mV
250 µV /V + 10 mV
Fluke 5520A
Parameter/Equipment
Range
CMC2, 4, 13 (±)
Comments
Capacitance – Generate3
(0.19 to 0.3999) nF
(0.4 to 1.0999) nF
(1.1 to 3.2999) nF
(3.3 to 10.9999) nF
(11 to 32.9999) nF
(33 to 109.999) nF
0.38 % output + 0.01 nF
0.38 % output + 0.01 nF
0.38 % output + 0.01 nF
0.19 % output + 0.01 nF
0.19 % output + 0.1 nF
0.19 % output + 0.1 nF
Fluke 5520A | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3898.01) Revised 07/24/2026 Page 4 of 8
Parameter/Equipment
Range
CMC2, 4, 13 (±)
Comments
Capacitance – Generate3
(cont)
(110 to 329.999) nF
(0.33 to 1.099 99) µF
(1.1 to 3.299 99) µF
(3.3 to 10.9999) µF
(11 to 32.9999) µF
(33 to 109.999) µF
(110 to 329.999) µF
(0.33 to 1.099 99) mF
(1.1 to 3.2999) mF
(3.3 to 10.9999) mF
(11 to 32.9999) mF
(33 to 110) mF
0.19 % output + 0.3 nF
0.19 % output + 1 nF
0.19 % output + 3 nF
0.19 % output + 10 nF
0.30 % output + 30 nF
0.34 % output + 100 nF
0.34 % output + 300 nF
0.34 % output + 1 µF
0.34 % output + 3 µF
0.34 % output + 10 µF
0.7 % output + 30 µF
1.0 % output + 100 µF
Fluke 5520A
DC Voltage – Measure5
100 mV
1 V
10 V
100 V
1000 V
0.006 mV
0.000 016 V
0.000 11 V
0.0016 V
0.016 V
HP 34401A
DC Current – Measure5
10 mA
100 mA
10 A
3 A
0.002 mA
0.022 mA
0.0003 A
0.0026 A
HP 34401A
Resistance – Measure5
100 Ω
1.0 kΩ
10 kΩ
100 kΩ
1 MΩ
10 MΩ
100 MΩ
0.0060 Ω
0.000 014 kΩ
0.000 14 kΩ
0.0014 kΩ
0.000 024 MΩ
0.000 50 MΩ
0.080 MΩ
HP 34401A
Parameter/Range
Frequency
CMC2, 4, 13 (±)
Comments
AC Current, Sine Wave –
Generate3
(29 to 329.99) µA
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
0.16 % output + 0.1 µA
0.12 % output + 0.1 µA
0.1 % output + 0.1 µA
0.25 % output + 0.15 µA
0.6 % output + 0.2 µA
1.2 % output + 0.4 µA
Fluke 5520A | ||
| 5 | - | AC Current, Sine WaveShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3898.01) Revised 07/24/2026 Page 5 of 8
Parameter/Range
Frequency
CMC2, 4, 13 (±)
Comments
AC Current, Sine Wave –
Generate3 (cont)
(0.33 to 3.2999) mA
(3.3 to 32.999) mA
(33 to 329.99) mA
(0.33 to 1.099 99) A
(1.1 to 2.999 99) A
(3 to 10.9999) A
(11 to 20.5) A
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
0.16 % output + 0.15 µA
0.1 % output + 0.15 µA
0.08 % output + 0.15 µA
0.16 % output + 0.2 µA
0.4 % output + 0.3 µA
0.8 % output + 0.6 µA
0.15 % output + 2 µA
0.075 % output + 2 µA
0.035 % output + 2 µA
0.065 % output + 2 µA
0.16 % output + 3 µA
0.32 % output + 4 µA
0.15 % output + 20 µA
0.075 % output + 20 µA
0.035 % output + 20 µA
0.08 % output + 50 µA
0.16 % output + 100 µA
0.32 % output + 200 µA
0.15 % output + 100 µA
0.036 % output + 100 µA
0.5 % output + 1000 µA
2.0 % output + 5000 µA
0.15 % output + 100 µA
0.05 % output + 100 µA
0.5 % output + 1000 µA
2.0 % output + 5000 µA
0.05 % output + 2000 µA
0.08 % output + 2000 µA
2.5 % output + 2000 µA
0.1 % output + 5000 µA
0.13 % output + 5000 µA
2.5 % output + 5000 µA
Fluke 5520A | - |
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3898.01) Revised 07/24/2026 Page 6 of 8
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Voltage, Sine Wave –
Measure5, 6, 7
100 mV
(1 to 750) V
(3 to 5) Hz
(5 to 10) Hz
(10 to 20) kHz
(20 to 50 kHz
(50 to 100) kHz
(100 to 300) kHz
(3 to 5) Hz
(5 to 10) Hz
10 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
0.06 mV
0.06 mV
0.06 mV
0.10 mV
0.16 mV
1.0 mV
0.32 V
0.31 V
0.30 V
0.60 V
1.2 V
7.6 V
HP 34401A
AC Current, Sine Wave –
Measure
5, 6, 7
1.0 A
3.0 A
(3 to 5) Hz
(5 to 10) Hz
10 Hz to 5 kHz
(3 to 5) Hz
(5 to 10) Hz
10 Hz to 5kHz
0.0008 A
0.0008 A
0.0008 A
0.026 A
0.011 A
0.0066 A
HP 34401A
Parameter/Equipment
Range
CMC2, 13 (±)
Comments
Electrical Calibration of
Thermocouple Indicators
Type J
Type K
(-210 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
0.20 °C
0.12 °C
0.10 °C
0.13 °C
0.18 °C
0.25 °C
0.14 °C
0.12 °C
0.19 °C
0.30 °C
Fluke 5520A | ||
| 7 | - | RTDsShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3898.01) Revised 07/24/2026 Page 7 of 8
Parameter/Range
Range
CMC2, 13 (±)
Comments
Electrical Calibration
of RTDs
Pt 385, 100 Ω
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(630 to 800) °C
0.04 °C
0.05 °C
0.07 °C
0.08 °C
0.09 °C
0.10 °C
0.21 °C
Fluke 5520A
III. Mechanical
Parameter/Equipment
Range
CMC2, 9, 12 (±)
Comments
Pressure – Measuring
Equipment
(-15 to 1500) psi
(20 to 20 000) psi
(20 000 to 60 000) psi
0.30 psi
0.0086 %
69 psi
Mensor CPC6000
Mensor CPB5800
Additel ADT680W
Torque – Measure
(250 to 2500) ft·lb
3.2 ft·lb
AKO torque sensors
V. Time and Frequency
Parameter/Equipment
Range
CMC2, 12 (±)
Comments
Frequency – Measure5, 8
100 mV to 750 V
(3 to 5) Hz
(5 to 10) Hz
(10 to 40) Hz
40 Hz to 300 kHz
0.006 Hz
0.005 Hz
0.006 Hz
0.0048 Hz
HP 34401A
Frequency – Measuring
Equipment13
(0.01 to 119.99) Hz
(120.0 to 1199.9) Hz
(1.20 to 11.999) kHz
(12.00 to 119.99) kHz
(120.0 to 1199.9) kHz
(1.20 to 2.0) MHz
2.5 µHz/Hz + 5 µHz
Fluke 5520A
________________________________________________________________ | See scope document |
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3898.01) Revised 07/24/2026 Page 8 of 8
1 This laboratory offers commercial calibration service and Field Calibration Service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of
measurement that a laboratory can achieve within its scope of accreditation when performing more
or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring
equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of
confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific
calibration performed by the laboratory may be greater than the CMC uncertainty due to the behavior
of the customer’s device and to influences from the circumstances of the specific calibration.
3 Field calibration service is available for these calibrations. Please note the actual measurement
uncertainties achievable on a customer's site can normally be expected to be larger than the CMC
found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place
of calibration and for other possible adverse effects such as those caused by transportation of the
calibration equipment. The usual allowance for the actual uncertainty introduced by the item being
calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual
measurement uncertainty achievable on a customer’s site being larger than the CMC.
4 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured
value in the ranges indicated. CMC are expressed as either a specific value that covers the full range
or as a percentage or fraction of the reading plus a fixed floor specification.
5 This spec. is valid over the temperature range of 18 °C to 28 °C after a 1 hour warm up time.
6 This spec. is valid for ac sinewave signals > 5% of the range. For inputs from 1 % to 5 % of range
and < 50 kHz add an additional error of 0.1 % of range and for 50 kHz to 100 kHz add 0.13 % of
range.
7 This spec. is valid with NPLC set to 10 or higher.
8 This spec is after a delay of 1 second minimum.
9 In the statement of CMC, percentages are percentage of reading, unless otherwise indicated.
10 In the statement of CMC, L is the numerical value of the nominal length of the device measured in
inches.
11 This scope meets A2LA’s P112 Flexible Scope Policy.
12 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges
indicated for the listed measurement parameter.
13 The CMC values listed for these parameters do not include a contribution from the Unit Under Test. | ||
| 9 | ISO/IEC 17025:2017 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Other Locations
1 other site in this organization