What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 3 scope lines.
A2LA certificate 7486.01 · 3 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017 | - | 0 to 0.4 % |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7486.01) Revised 11/14/2025 Page 2 of 2
Parameter/Equipment
Range
CMC2, 3 (±)
Comments
Relative Humidity –
Measure
(5 to 30) % RH
(30 to 95) % RH
0.23 % RH
0.33 % RH
Rotronic HygroClip HC2
with HygroGen 2 HC2A-S
____________________________________
1 This laboratory offers commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a
percent or fraction of the reading plus a fixed floor specification.
4 This scope meets A2LA’s P112 Flexible Scope Policy.
5 In the statement of CMC, percentages are percentage of reading, unless otherwise indicated. | ||
| 3 | ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Other Locations
3 other sites in this organization
Accreditation data refreshed from the A2LA register on .