Pavana
Otto-Hahn-Straße 12-16, 25813, Husum, Germany
Visit website- Accredited standards
- 5
- DAKKS certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the DAKKS scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 5 standard numbers and the 1 official name we hold. When no standard matches, it searches the method text of every scope line.
IEC 61400-12-1
IEC 61400-12-5
IEC 61400-50-1
IEC 61400-50-2
ISO 9613-2Acoustics - Attenuation of sound during propagation outdoors - Part 2: Engineering method for the prediction of sound pressure levels outdoors
IEC 61400 -12 -1 Ed. 2.0; IEC 61400 -12 -1; IEC 61400 -12 -5; IEC 61400 -50; IEC 61400 -50 -1; IEC 61400 -50 -2; FGW TR 6, Rev. 1 2; VA7.2 -2
IEC 61400 -12 -1 Ed. 2.0; IEC 61400 -12 -1; IEC 61400 -12 -5; IEC 61400 -50; IEC 61400 -50 -1; IEC 61400 -50 -2; FGW TG 6 Rev. 1 2; VA7.2 -4
DIN ISO 9613 -2; TA Lärm; VA7.2 -3; VA7.2 -6; FGW TG 10, Rev. 3; VA7.2 -8
Read from the scope as published by DAKKS. Register refreshed 2026-11-06.
Scope as published by DAKKS
5 lines
ISO/IEC 17025
ActiveD-PL-20910-01-00
Accredited scope, certificate D-PL-20910-01-00
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | DIN EN ISO/IEC 17025:2018; DIN EN ISO 9001 | - | - |
| 2 | - | wind turbines; wind climatological input data; site qualityShow page textExtracted from the scope document; tables may not line up. View scope for the original. Annex to the Accreditation Certificate D-PL-20910-01-00
Valid from : 09.12.2024
Date of issue : 09.12.2024 Page 2 of 5
Test in the fields:
1 Determination of wind potential and energy yields of wind turbines including testing of wind
climatological input data; determination of the site quality (H, K, C) ............................................... 3
2 Accomplishment and evaluation of wind measurement s by anemometer and LiDAR, including
LiDAR verification and RSD plausibility checks (H, K) ........................................................................ 4
3 Accomplishment of shadow flicker calculations of wind turbines (H, K, C) ...................................... 4
4 Accomplishment of noise immission calculations of wind turbines (H, K, C) .................................... 5
5 Accomplishment of extreme wind speed estimations (H, C) ............................................................ 5
6 Determination of site quality following commissio ning (H) .............................................................. 5
Flexibility of the scope of accreditation:
Within the scope of accreditation marked with *, the testing laboratory is permitted, without being
required to inform and obtain prior approval from DAkkS, to use standards or equivalent testing
methods listed here with different issue dates (Flexibility Category A).
The testing laboratory maintains an up-to-date list of the test methods implemented or offered
within the scope of accreditation on its website. | - |
| 3 | IEC 61400 -12 -1 Ed. 2.0; IEC 61400 -12 -1; IEC 61400 -12 -5; IEC 61400 -50; IEC 61400 -50 -1; IEC 61400 -50 -2; FGW TR 6, Rev. 1 2; VA7.2 -2 | - | - |
| 4 | IEC 61400 -12 -1 Ed. 2.0; IEC 61400 -12 -1; IEC 61400 -12 -5; IEC 61400 -50; IEC 61400 -50 -1; IEC 61400 -50 -2; FGW TG 6 Rev. 1 2; VA7.2 -4 | - | - |
| 5 | DIN ISO 9613 -2; TA Lärm; VA7.2 -3; VA7.2 -6; FGW TG 10, Rev. 3; VA7.2 -8 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Germany
- Moeller Operating EngineeringItzehoe · ~65 kmDAKKSShares 1 accredited test methodEN ISO 9001
- TRIWALAItzehoe · ~65 kmDAKKSShares 1 accredited test methodEN ISO 9001
- AGROLAB LUFAKiel · ~67 kmDAKKSShares 1 accredited test methodEN ISO 9001
- AGROLAB UmweltKiel · ~67 kmDAKKSShares 1 accredited test methodEN ISO 9001
- PlantonKiel · ~70 kmDAKKSShares 1 accredited test methodEN ISO 9001
Accreditation data refreshed from the DAKKS register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.