FindTestingLabs
Registers refreshed 2026-10-18.See refresh dates
United States

Pace Analytical Services, LLC - Huntington Beach

16742 Gothard Street, Suites 117-118, 92647, Huntington Beach, CA, United States

A2LA|3778.02ISO/IEC 17025Register refreshed 2026-10-09
Certificates
1
Scope items
2
Standards
0
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at Pace Analytical Services, LLC - Huntington Beach?

Claim this profile to keep it accurate.

Register record

A2LARefreshed
3778.02Active

Accredited standards

We have not yet extracted the standard numbers from this lab’s scope document. The scope text we hold is below.

Scope as published by A2LA

2 lines
A2LA

ISO/IEC 17025

Active

3778.02

The scope document we hold says it is valid until 2028-01-31.

View scope

Accredited scope, certificate 3778.02

This scope has not been split into individual lines yet. Below is the text of the scope document as published.

Part 1 of 2

(A2LA Cert. No. 3778.02) Revised 07/20/2026 Page 1 of 1 SCO PE OF ACCREDITATION TO ISO/IEC 17025:2017 PAC E ANALYTICAL SERVICES, LLC – HUNTINGTON BEACH 16742 Gothard Street Suites 117-118 Huntington Beach, CA 92647 Tina Shidel Phone: 386-368-7410 tina.buttermore@pacelabs.com BI OLOGICAL Va lid To: January 31, 2028 Certificate Number: 3778.02 In r ecognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory to perform the following tests on the materials listed below: Test/Technology Test Method(s) Reference Method Matrices Legionella Enumeration – Legionella spp. and Serogroups ENV-SOP-BDSG-0008 CDC: Procedures for the Recovery of Legionella from the Environment Water and Swabs Total Coliforms and Escherichia coli Presence/Absence ENV-SOP-BDSG-0029 SM 9223B Water and Swabs <USP 797> Enumeration, Media Fill – Aerobic Bacteria and Fungi ENV-SOP-BDSG-0020 ENV-SOP-BDSG-0061 ENV-SOP-BDSG-0064 USP-NF <797>, <1116> Air, Surfaces, Bulk, and Liquid ENVI RONMENTAL In r ecognition of the successful completion of the A2LA evaluation process, (including an assessment of the laboratory's compliance with A2LA’s R261 – Specific Requirements – Environmental Microbiology Laboratory Accreditation Program ), accreditation is granted to this laboratory to perform the following tests on the materials listed below: Test/Technology Test Method(s) Reference Method Matrix(ces) Microbial Enumeration and Identification – Aerobic Bacteria and Fungi ENV-SOP-BDSG-0061 ENV-SOP-BDSG-0064 -------------------- Air, Surfaces, Bulk, and Liquid Spore Trap – Fungal Spores, Fungal Structures, Hyphae, Pollen. Insect Fragments, and Fibrous Material ENV-SOP-BDSG-0044 ASTM D7391-20 Air Direct Microscope Exam – Fungal Spores, Fungal Structures, Hyphae, Pollen, Insect Fragments, and Fibrous Material ENV-SOP-BDSG-0043 ASTM D7658-17 Surfaces and Bulk

Part 2 of 2

For the tests to which this accreditation applies, please refer to the laboratory’s Biological Scope of Accreditation. Accredited Laboratory A2LA has accredited PACE ANALYTICAL SERVICES, LLC - HUNTINGTON BEACH Huntington Beach, CA for technical competence in the field of Biological Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This laboratory also meets the requirements of the A2LA R261 – Specific Requirements – Environmental Microbiology Laboratory Accreditation Program. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 18th day of May 2026. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 3778.02 Valid to January 31, 2028

Text extracted from the accredited scope document. Layout and tables from the original may not carry over; the scope document itself is the authoritative copy.

Location

16742 Gothard Street, Suites 117-118, Huntington Beach, CA, 92647, US

33.67833, -118.00002

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.