MAXLAB Testing Co.,
1/F, Building B, Xinshidai GR Park, Shiyan Street, Bao’an District, Shenzhen, Guangdong, China, Shenzhen, 518052, People's Republic of China, Shenzhen, China
- Accredited standards
- 47
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 47 standard numbers and the 29 official names we hold. When no standard matches, it searches the method text of every scope line.
ETSI21
ETSI EN 300 220-1
ETSI EN 300 220-2
ETSI EN 300 220-3-1
ETSI EN 300 220-3-2
ETSI EN 300 220-4
ETSI EN 300 328Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz band; Harmonised Standard for access to radio spectrum
ETSI EN 300 330Short Range Devices (SRD); Radio equipment in the frequency range 9 kHz to 25 MHz and inductive loop systems in the frequency range 9 kHz to 30 MHz; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
ETSI EN 300 440
ETSI EN 301 489-1
ETSI EN 301 489-3
ETSI EN 301 489-17
ETSI EN 301 489-19
Show all 21
ETSI EN 301 489-52
ETSI EN 301 511Global System for Mobile communications (GSM); Mobile Stations (MS) equipment; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
ETSI EN 301 893
ETSI EN 301 908-1
ETSI EN 301 908-2
ETSI EN 301 908-13
ETSI EN 303 345-1
ETSI EN 303 413Satellite Earth Stations and Systems (SES); Global Navigation Satellite System (GNSS) receivers; Radio equipment operating in the 1 164 MHz to 1 300 MHz and 1 559 MHz to 1 610 MHz frequency bands; Harmonised Standard for access to radio spectrum
ETSI EN 303 417
IEC 61000 series11
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments
IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
CISPR6
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement+1 national
National versions in the same scope
AS/NZS CISPR 11national version with changes
CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission+1 national
National versions in the same scope
AS/NZS CISPR 14.1national version with changes
CISPR 14-2Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard
CISPR 15Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment+1 national
National versions in the same scope
AS/NZS CISPR 15national version with changes
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+1 national
National versions in the same scope
AS/NZS CISPR 32identical to it
CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirements
IEC4
IEC 61547Equipment for general lighting purposes - EMC immunity requirements
IEC 62311Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz to 300 GHz)
IEC 62368-1Audio/video, information and communication technology equipment - Part 1: Safety requirements+1 national
National versions in the same scope
AS/NZS 62368.1national version with changes
IEC 62479Assessment of the compliance of low power electronic and electrical equipment with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz)
Other standards5
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
EN 50663Generic standard for assessment of low power electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (10 MHz - 300 GHz)
EN 50665
FCC PART 15Radio Frequency Devices
ICES-001Industrial, Scientific and Medical (ISM) Equipment
EN 55035; BS EN 55035; CISPR 35; EN 55014-2; BS EN 55014-2; CISPR 14-2; EN 61547; BS EN 61547; IEC 61547; EN 61000-6-1; IEC 61000-6-1; BS EN IEC 61000-6-1; EN 61000-6-2; IEC 61000-6-2; BS EN IEC 61000-6-2; EN IEC 61000-6-3; IEC 61000-6-3; BS EN 61000-6-3; EN 61000-6-4; IEC 61000-6-4; BS EN IEC 61000-6-4; ETSI EN 301 489-1; ETSI EN 301 489-3; ETSI EN 301 489-17; ETSI EN 301 489-19; ETSI EN 301 489-52; CFR 47 FCC Part 15 Subpart C (using ANSI C63.10-2013); CFR 47 FCC Part 15 Subpart E (using ANSI C63.10-2013); CFR 47 FCC Part 22 (cellular), Part 24, Part 25 (below 3GHz), Part 27 (using ANSI/TIA-603-E, TIA-102.CAAA-E); ANSI C63.26-2015; RSS-130; RSS-132; RSS-133; RSS-139; RSS-199; RSS-210; RSS-216; RSS-247; RSS-248; RSS-310; RSS-GEN; ETSI EN 300 220-1; ETSI EN 300 220-2; ETSI EN 300 220-3-1; ETSI EN 300 220-3-2; ETSI EN 300 220-4; ETSI EN 300 330; ETSI EN 300 440; ETSI EN 300 328; ETSI EN 303 413; ETSI EN 303 345-1; ETSI EN 301 893; ETSI EN 303 417; ETSI EN 301 511; ETSI EN 301 908-1; ETSI EN 301 908-2; ETSI EN 301 908-13; AS/NZS 4268; RSS-102 Issue 5; EN 62479; EN 50663; EN 50665; EN 62311; IEC 62368-1; EN IEC 62368-1; UL 62368-1; CAN/CSA-C22.2 No. 62368-1; BS EN 62368-1; AS/NZS 62368.1
CFR 47 FCC Part 15 Subpart B (using ANSI C63.4-2014); CFR 47 FCC Part 18 (using MP-5:1986); ANSI C63.10:2020+COR 1:2023; ICES-001; ICES-003; ICES-005; CISPR 11; EN 55011; AS/NZS CISPR 11; BS EN 55011; CISPR 14.1; EN 55014-1; AS/NZS CISPR 14.1; BS EN 55014-1; CISPR 15; EN 55015; AS/NZS CISPR 15; BS EN 55015; EN 55032; BS EN 55032; CISPR 32; AS/NZS CISPR 32; EN 61000-3-2; IEC 61000-3-2; BS EN 61000-3-2; EN 61000-3-3; IEC 61000-3-3; BS EN 61000-3-3; EN 61000-4-2; IEC 61000-4-2; BS EN 61000-4-2; EN 61000-4-4; IEC 61000-4-4; BS EN 61000-4-4; EN 61000-4-5; IEC 61000-4-5; BS EN 61000-4-5; EN 61000-4-6; IEC 61000-4-6; BS EN 61000-4-6; EN IEC 61000-4-11; IEC 61000-4-11; BS EN IEC 61000-4-11
ANSI C63.4:2014; FCC MP-5 (February 1986); ANSI C63.10:2013; ANSI/TIA-603-E-2016; TIA-102.CAAA-E-2016; ANSI C63.26-2015
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
5 lines
ISO/IEC 17025
Active4707.01
The scope document we hold says it is valid until 2026-11-30.
Accredited scope, certificate 4707.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | CFR 47 FCC Part 15 Subpart B (using ANSI C63.4-2014); CFR 47 FCC Part 18 (using MP-5:1986); ANSI C63.10:2020+COR 1:2023; ICES-001; ICES-003; ICES-005; CISPR 11; EN 55011; AS/NZS CISPR 11; BS EN 55011; CISPR 14.1; EN 55014-1; AS/NZS CISPR 14.1; BS EN 55014-1; CISPR 15; EN 55015; AS/NZS CISPR 15; BS EN 55015; EN 55032; BS EN 55032; CISPR 32; AS/NZS CISPR 32; EN 61000-3-2; IEC 61000-3-2; BS EN 61000-3-2; EN 61000-3-3; IEC 61000-3-3; BS EN 61000-3-3; EN 61000-4-2; IEC 61000-4-2; BS EN 61000-4-2; EN 61000-4-4; IEC 61000-4-4; BS EN 61000-4-4; EN 61000-4-5; IEC 61000-4-5; BS EN 61000-4-5; EN 61000-4-6; IEC 61000-4-6; BS EN 61000-4-6; EN IEC 61000-4-11; IEC 61000-4-11; BS EN IEC 61000-4-11 | - | to 40 GHz |
| 2 | EN 55035; BS EN 55035; CISPR 35; EN 55014-2; BS EN 55014-2; CISPR 14-2; EN 61547; BS EN 61547; IEC 61547; EN 61000-6-1; IEC 61000-6-1; BS EN IEC 61000-6-1; EN 61000-6-2; IEC 61000-6-2; BS EN IEC 61000-6-2; EN IEC 61000-6-3; IEC 61000-6-3; BS EN 61000-6-3; EN 61000-6-4; IEC 61000-6-4; BS EN IEC 61000-6-4; ETSI EN 301 489-1; ETSI EN 301 489-3; ETSI EN 301 489-17; ETSI EN 301 489-19; ETSI EN 301 489-52; CFR 47 FCC Part 15 Subpart C (using ANSI C63.10-2013); CFR 47 FCC Part 15 Subpart E (using ANSI C63.10-2013); CFR 47 FCC Part 22 (cellular), Part 24, Part 25 (below 3GHz), Part 27 (using ANSI/TIA-603-E, TIA-102.CAAA-E); ANSI C63.26-2015; RSS-130; RSS-132; RSS-133; RSS-139; RSS-199; RSS-210; RSS-216; RSS-247; RSS-248; RSS-310; RSS-GEN; ETSI EN 300 220-1; ETSI EN 300 220-2; ETSI EN 300 220-3-1; ETSI EN 300 220-3-2; ETSI EN 300 220-4; ETSI EN 300 330; ETSI EN 300 440; ETSI EN 300 328; ETSI EN 303 413; ETSI EN 303 345-1; ETSI EN 301 893; ETSI EN 303 417; ETSI EN 301 511; ETSI EN 301 908-1; ETSI EN 301 908-2; ETSI EN 301 908-13; AS/NZS 4268; RSS-102 Issue 5; EN 62479; EN 50663; EN 50665; EN 62311; IEC 62368-1; EN IEC 62368-1; UL 62368-1; CAN/CSA-C22.2 No. 62368-1; BS EN 62368-1; AS/NZS 62368.1 | - | to 40 GHz |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4707.01) Revised 01/10/2025 Page 3 of 4
Test Test Methods1:
Product Safety (cont.)
Luminaire BS/EN 60598-1; EN IEC 60598-1; IEC 60598-1;
AS/NZS 60598.1;
IEC 60598-2-1; EN IEC 60598-2-1; AS/NZS 60598.2.1;
EN 60598-2-2; IEC 60598-2-2; AS/NZS 60598.2.2;
EN 60598-2-3; IEC 60598-2-3; AS/NZS 60598.2.3;
EN 60598-2-4; IEC 60598-2-4; AS/NZS 60598.2.4;
EN 60598-2-5; IEC 60598-2-5;
AS/NZS 60598.2.5; EN 60598-2-8; IEC 60598-2-8;
AS/NZS 60598.2.8; EN 60598-2-10; IEC 60598-2-10;
AS/NZS 60598.2.10; EN 60598-2-11; IEC 60598-2-11;
EN 60598-2-12; IEC 60598-2-12; AS/NZS 60598.2.12;
EN 60598-2-13; IEC 60598-2-13; IEC 60598-2-17;
EN 60598-2-17; AS/NZS 60598.2.17; EN 60598-2-18;
IEC 60598-2-18; AS/NZS 60598.2.18; EN 60598-2-19;
IEC 60598-2-19:1981+A1; EN 60598-2-20; IEC 60598-2-20;
AS/NZS 60598.2.20; EN 60598-2-22; EN 60598-2-22;
AS/NZS 60598.2.22; BS/EN 62031; EN IEC 62031;
IEC 62031; AS/NZS 62031; UL 1598, UL 153, UL 8750,
UL 1576, UL 588, UL 48, UL 2108, UL 1786,
UL 1838, UL 8800
Lamp Control Gear EN 61347-1; IEC 61347-1; AS/NZS 61347.1;
EN 61347-2-2; IEC 61347-2-2; AS/NZS 61347.2.2;
EN 61347-2-3; IEC 61347-2-3; AS/NZS 61347.2.3;
EN 61347-2-4; IEC 61347-2-4; AS/NZS 61347.2.4;
EN 61347-2-8; IEC 61347-2-8; AS/NZS 61347.2.8;
EN 61347-2-11; IEC 61347-2-11; AS/NZS 61347.2.11;
EN 61347-2-13; IEC 61347-2-13:2014; UL 1993
Household Appliances & Hand-held
Tools
EN/IEC 60335-1; AS/NZS 60335-1; UL 60335-1;
EN/IEC 60335-2-2; AS/NZS 60335.2.2; UL 60335-2-2;
EN/IEC 60335-2-8; AS/NZS 60335.2.8; UL 60335-2-8;
EN/IEC 60335-2-23; AS/NZS 60335.2.23;
UL 60335-2-14; UL 60335-2-24; UL 60335-2-29;
EN/IEC 60335-2-30; AS/NZS 60335.2.30;
EN/IEC 60335-2-32; AS/NZS 60335.2.32; UL 60335-2-32;
UL 60335-2-40; UL 60335-2-52; UL 60335-2-69;
EN/IEC 60335-2-80; AS/NZS 60335.2.80;
UL 60335-2-82; UL 60335-2-89;
EN/IEC 60335-2-98; AS/NZS 60335.2.98;
UL 859, UL 1017, UL 982, UL 1082, UL1647, UL 507,
UL 1026, UL 1083, UL 1278, UL 858, UL 1559, UL 2021,
UL 130, UL 1450, UL 2272, UL 283,
UL 1310, UL 1012, UL 2595, UL 2089,
UL 62841-1, UL 62841-2-1, UL 62841-2-2, UL 62841-2-3
UL 62841-2-6, UL 62841-2-11, UL 62841-2-17 | ||
| 4 | ANSI C63.4:2014; FCC MP-5 (February 1986); ANSI C63.10:2013; ANSI/TIA-603-E-2016; TIA-102.CAAA-E-2016; ANSI C63.26-2015 | - | to 40000 MHz |
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
MAXLAB TESTING CO., LTD.
Shenzhen, People’s Republic of China
for technical competence in the field of
Electrical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 25th day of November 2024.
__ _____________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 4707.01
Valid to November 30, 2026
Revised January 10, 2025 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Labs with overlapping accredited scope in China
- CTSL Testing (Dongguan) Co.,DongguanA2LAShares 2 accredited test methodsANSI C63.4:2014ICES-001
- DEKRA Testing and Certification (Shanghai)ShanghaiA2LAShares 2 accredited test methodsANSI C63.4:2014ICES-001
- DEKRA Testing and Certification (Suzhou) Co.,Suzhou, Jiangsu ProvinceA2LAShares 2 accredited test methodsANSI C63.4:2014ICES-001
- Dongguan Nore Testing Center Co.,Dongguan, GuangdongA2LAShares 2 accredited test methodsANSI C63.4:2014ICES-001
- DongGuan ShuoXin Electronic Technology Co.,GuangDongA2LAShares 2 accredited test methodsANSI C63.4:2014ICES-001
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.