CROSS TECHNOLOGIES, INC - GREENVILLE

1200 Woodruff Road, Suite A-19, 29607, Greenville, SC, United States

Visit website
A2LA 1741.04ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
18
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 18 scope lines.

A2LA certificate 1741.04 · 18 lines

LineMethodMatrixRange
1--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.04) Revised 01/20/2026 Page 1 of 17 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 CROSS TECHNOLOGIES, INC 1200 Woodruff Road Suite A-19 Greenville, SC 29607 Connie Foster Phone: 877 841 6202 CALIBRATION Valid To: May 31, 2027 Certificate Number: 1741.04 In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory at the location listed above as well as the satellite laboratory location listed below to perform the following calibrations 1, 9: I. Chemical Parameter/Equipment Range CMC2 (±) Comments pH Meters3 – Fixed Points 4 pH 7 pH 10 pH 0.03 pH 0.04 pH 0.07 pH Standard pH solutions Conductivity Meters3 – Fixed Points 10 µS/cm 100 µS/cm 1000 µS/cm 0.63 µS/cm 2.2 µS/cm 5.2 µS/cm Standard conductivity solutions II. Dimensional Parameter/Equipment Range CMC2, 4 (±) Comments Thickness & Snap Gages3 Up to 2 in (7.4 + 7.8L) µin + 0.6R Gage blocks Calipers3 Up to 40 in (5.6 + 10L) µin + 0.6R Gage blocks Linear Indicators3 (Dial & Test) Up to 2 in (5.9 + 7.6L) µin + 0.6R Gage blocks
to 2 in
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.04) Revised 01/20/2026 Page 2 of 17 Parameter/Equipment Range CMC2, 4 (±) Comments Micrometers3 – (Inside & Outside) Up to 40 in (5.6 + 10L) µin + 0.6R Gage blocks Height Gages3 Up to 40 in (5.6 + 10L) µin + 0.6R Gage blocks Pin Gages3 Up to 1 in 90 µin Digimatic micrometer Feeler Gages3 Up to 0.2 in 90 µin Digimatic micrometer Metal Tape Measures & Steel Rules3 Up to 25 ft Up to 12 in (2.9 + 9.2L) µin + 0.6R 0.0027 in + 0.6R Gage blocks Caliper Angle Indicators & Protractors3 30°, 45°, 60°, 75°, 90° 0.037° Angle block set Optical Comparators3 – X-Y Linearity Magnification Angle Up to 12 in 10X to 250X Up to 90 ° 180 µin 0.014 in 0.06° Glass master & scales Glass master & scales Angle block set Vision systems3 – X-Y Linearity Z Axis Up to 18 in Up to 12 in Up to 16 in Up to 32 in Up to 63 in Up to 4 in (52 + 2.9L) µin (160 + 0.9L) µin (160 + 1.6L) µin (160 + 3.8L) µin (160 + 4.6L) µin 60 µin Grid plate Glass Scale Gage blocks Surface Plates3 – Grades AA, A, & B – Repeatability Flatness 0.002 in Up to 60DL in (>60 to 120) DL in 27 µin (31 + 0.2DL) µin (30 + 0.3DL) µin Repeat-o-meter Federal level systems
to 40 in
3--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.04) Revised 01/20/2026 Page 3 of 17 Parameter/Equipment Range CMC2, 4 (±) Comments Surface Finish Specimens – Waviness, Texture & Roughness – Ra (2 to 500) µin 2.7 μin Surface analyzer Surface Roughness Meters & Profilometers3 – Ra 15.3 µin 117.3 µin 1.1 µin Precision roughness standard Formtesters3 – Gage Head Displacement Spindle Verification Axis to Spindle Alignment Z-Axis Straightness Up to 2 mm 0.15 µm to 2mm (25 to 225) mm Up to 150 mm 0.1 µm 0.08 µm 0.4 µm / 200 mm 0.1 µm Gage blocks Roundness sphere Cylindrical square Optical flat Contour Systems3 – Vertical Displacement Horizontal Displacement Radius Compensation X-Axis Straightness (2.5 to 60) mm (5 to 100) mm (2.56 to 10) mm Up to 150 mm 0.1 µm 9.3 µm 2.6 µm 0.1 µm Gage blocks Spheres Spheres Optical flat III. Dimensional Testing/Calibration1 Parameter/Equipment Range CMC2, 4, 8 (±) Comments Surface Finish – Measure7 (2 to 500) µin 2.7 µin Surface analyzer Form – Measure7 Roundness Straightness Cylindricity Up to 340 mm Up to 150 mm Up to 200 mm (0.087 + 0.0005D) µm 0.1 µm 0.6 µm / 200 mm Formtester
2 to 500 µin
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.04) Revised 01/20/2026 Page 4 of 17 Parameter/Equipment Range CMC2, 4, 8 (±) Comments Length7 – X-Axis Y-Axis Z-Axis Volumetric Up to 80 in (2000 mm) Up to 59 in (1000 mm) Up to 27 in (800 mm) Up to 95 in (2400 mm) (98 + 9.8L) µin (98 + 9.2L) µin (98 + 9.0L) µin (98 + 9.9L) µin Coordinate Measurement Machine Length7 – X-Y Axis Optical Contact Z-Axis Optical Laser Contact (18 x 18) in (18 x 18) in Up to 6 in Up to 6 in Up to 6 in (200 + 1.2L) µin (200 + 1.1L) µin (250 + 0.3L) µin (260 + 0.3L) µin (250 + 0.3L) µin Vision machine IV. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 5, 6 (±) Comments DC Voltage3 – Measure (0 to 100) mV 100 mV to 1 V (1 to 10) V (10 to 100) V (100 to 1000) V (1 to 10) kV (10 to 100) kV 11 µV/V + 3 µV 10 µV/V + 0.3 µV 10 µV/V + 0.05 µV 12 µV/V + 0.3 µV 27 µV/V + 0.1 µV 0.05 % + 0.03 V 0.07 % + 0.3 V Agilent/HP 3458A Vitrek 4700 w/HVL- 100 DC Voltage3 – Generate (0 to 330) mV (0 to 3.3) V (0 to 33) V (30 to 330) V (100 to 1020) V 25 µV/V + 1 µV 14 µV/V + 2 µV 15 µV/V + 15 µV 22 µV/V + 150 µV 22 µV/V + 1.5 mV Fluke 5522A
5--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.04) Revised 01/20/2026 Page 5 of 17 Parameter/Equipment Range CMC2, 4, 8 (±) Comments DC Power3 – Generate 33 mV to 1020 V (0.33 to 329.99) mA (0.33 to 2.9999) A (3 to 20.5) A (0.01 to 330) W (0.33 to 3.3) kW (3.3 to 20.5) kW 0.03 % 0.03 % 0.09 % Fluke 5522A DC Current3 – Measure (0 to 100) nA 100 nA to 1 µA (1 to 10) µA (10 to 100) µA 100 µA to 1 mA (1 to 10) mA (10 to 100) mA 100 mA to 1 A (1 to 300) A 32 µA/A + 0.04 nA 23 µA/A + 0.04 nA 23 µA/A + 0.1 nA 23 µA/A + 0.8 nA 23 µA/A + 5 nA 23 µA/A + 50 nA 37 µA/A + 0.5 µA 0.012 % + 10 µA 0.25 % Agilent/HP 3458A Empro shunt /DMM DC Clamp-On Meters3 – Non-Toroidal Up to 1000 A 0.65 % + 0.5 A Fluke 5522A w/5500 coil DC Current3 – Generate (0 to 330) µA (0 to 3.3) mA (0 to 33) mA (0 to 330) mA (0 to 1.1) A (1.1 to 3) A (0 to 11) A (11 to 21) A 0.018 % + 0.02 µA 0.012 % + 0.05 µA 0.012 % + 0.25 µA 0.012 % + 2.5 µA 0.024 % + 40 µA 0.046 % + 40 µA 0.06 % + 500 µA 0.12 % + 750 µA Fluke 5522A Resistance3 – Measure (0 to 10) Ω (10 to 100) Ω 100 Ω to 1 kΩ (1 to 10) kΩ (10 to 100) kΩ 100 kΩ to 1 MΩ (1 to 10) MΩ (10 to 100) MΩ 100 MΩ to 1 GΩ 18 µΩ/Ω + 50 µΩ 15 µΩ/Ω + 0.5 mΩ 14 µΩ/Ω + 0.5 mΩ 14 µΩ/Ω + 5 mΩ 12 µΩ/Ω + 50 mΩ 17 µΩ/Ω + 2 Ω 52 µΩ/Ω + 100 Ω 0.05 % + 1 kΩ 0.5 % + 10 kΩ Agilent/HP 3458A
0.033 to 1020 V
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.04) Revised 01/20/2026 Page 6 of 17 Parameter/Equipment Range CMC2, 5, 6 (±) Comments Resistance3 – Generate Fixed Points 3 (0 to 11) Ω (11 to 33) Ω (33 to 110) Ω 110 Ω to 1.1 kΩ (1.1 to 11) kΩ (11 to 110) kΩ 110 kΩ to 1.1 MΩ (1.1 to 3.3) MΩ (3.3 to 11) MΩ (11 to 33) MΩ (33 to 110) MΩ (110 to 330) MΩ (330 to 1100) MΩ 10 MΩ 100 MΩ 1 G Ω 10 G Ω 1000 G Ω 49 µΩ/Ω + 0.001 Ω 37 µΩ/Ω + 0.0015 Ω 34 µΩ/Ω + 0.0014 Ω 34 µΩ/Ω + 0.002 Ω 34 µΩ/Ω + 0.02 Ω 34 µΩ/Ω + 0.2 Ω 39 µΩ/Ω + 2 Ω 73 µΩ/Ω + 30 Ω 0.016 % + 50 Ω 0.03 % + 2.5 kΩ 0.06 % + 3 kΩ 0.36 % + 100 kΩ 1.8 % + 500 kΩ 1.2 % 1.2 % 1.2 % 1.2 % 1.2 % Fluke 5522A Set of resistors Capacitance3 – Generate 40 pF to 1.2 µF (220.0 to 399.9) pF (0.4 to 1.0999) nF (1.1 to 3.2999) nF (3.3 to 10.9999) nF (11 to 109.999) nF (110 to 329.999) nF (0.33 to 1.099 99) µF (1.1 to 3.299 99) µF (3.3 to 10.9999) µF (11 to 32.9999) µF (33 to 109.999) µF (110 to 329.999) µF (.33 to 1.099 99) mF (1.1 to 3.299 99) mF (3.3 to 10.9999) mF (11 to 32.9999) mF (33 to 110) mF -- (10 to 10 000) Hz (10 to 10 000) Hz (10 to 3000) Hz (10 to 1000) Hz (10 to 1000) Hz (10 to 1000) Hz (10 to 600) Hz (10 to 300) Hz (10 to 150) Hz (10 to 120) Hz (10 to 80) Hz (0 to 50) Hz (0 to 20) Hz (0 to 6) Hz (0 to 2) Hz (0 to 0.6) Hz (0 to 0.2) Hz 0.5 % + 3 pF 0.6 % + 10 pF 0.6 % + 0.01 nF 0.6 % + 0.01 nF 0.3 % + 0.1 nF 0.3 % + 0.1 nF 0.3 % + 0.3 nF 0.3 % + 1 nF 0.3 % + 3 nF 0.3 % + 10 nF 0.49 % + 30 nF 0.55 % + 100 nF 0.54 % + 300 nF 0.55 % + 1 µF 0.55 % + 3 µF 0.56 % + 10 µF 0.91 % + 30 µF 1.4 % + 100 µF Agilent/HP 4440B Fluke 5522A
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.04) Revised 01/20/2026 Page 7 of 17 Parameter/Range Frequency CMC2, 5, 6 (±) Comments AC Voltage3 – Generate (1 to 33) mV (33 to 330) mV (0.33 to 3.3) V (3.3 to 33) V (3.3 to 33) V (33 to 330) V (330 to 1020) V (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 10 kHz 0.096 % + 6 µV 0.019 % + 6 µV 0.025 % + 6 µV 0.12 % + 6 µV 0.42 % + 12 µV 0.96 % + 50 µV 0.036 % + 8 µV 0.018 % + 8 µV 0.02 % + 8 µV 0.042 % + 8 µV 0.096 % + 32 µV 0.24 % + 70 µV 0.036 % + 50 µV 0.019 % + 60 µV 0.023 % + 60 µV 0.036 % + 50 µV 0.084 % + 130 µV 0.29 % + 600 µV 0.036 % + 650 µV 0.019 % + 600 µV 0.029 % + 600 µV 0.042 % + 600 µV 0.11 % + 1.6 mV 0.023 % + 2 mV 0.025 % + 6 mV 0.03 % + 6 mV 0.036 % + 6 mV 0.24 % + 50 mV 0.036 % + 10 mV Fluke 5522A AC Voltage3 – Measure Up to 10 mV (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 0.03 % + 0.03 % of rng 0.02 % + 0.01 % of rng 0.03 % + 0.01 % of rng 0.1 % + 0.01 % of rng 0.5 % + 0.01 % of rng 4 % + 0.02 % of rng HP 3458A
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.04) Revised 01/20/2026 Page 8 of 17 Parameter/Range Frequency CMC2, 5, 6 (±) Comments AC Voltage3 – Measure (cont) 10 mV to 10 V (10 to 100) V (100 to 700) V Up to 10 kV (10 to 70) kV (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz Up to 60 Hz Up to 60 Hz 0.008 % + 0.004 % of rng 0.008 % + 0.002 % of rng 0.014 % + 0.002 % of rng 0.03 % + 0.002 % of rng 0.08 % + 0.002 % of rng 0.3 % + 0.01 % of rng 0.02 % + 0.004 % of rng 0.02 % + 0.002 % of rng 0.02 % + 0.002 % of rng 0.035 % + 0.002 % of rng 0.12 % + 0.002 % of rng 0.4 % + 0.01 % of rng 0.041 % + 0.004 % of rng 0.041 % + 0.002 % of rng 0.061 % + 0.002 % of rng 0.013 % + 0.002 % of rng 0.31 % + 0.002 % of rng 0.15 % + 0.1 V 0.15 % + 0.6 V Vitrek 4700 w/HVL- 100 AC Current3 – Generate (0 to 0.33) mA (0.33 to 3.3) mA (3.3 to 33) mA (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz 0.24 % + 0.1 µA 0.18 % + 0.1 µA 0.15 % + 0.1 µA 0.36 % + 0.15 µA 0.96 % + 0.2 µA 2 % + 0.4 µA 0.25 % + 0.15 µA 0.16 % + 0.15 µA 0.13 % + 0.15 µA 0.25 % + 0.2 µA 0.6 % + 0.3 µA 1.2 % + 0.6 µA 0.22 % + 2 µA 0.11 % + 2 µA 0.05 % + 2 µA 0.096 % + 2 µA 0.24 % + 3 µA 0.48 % + 4 µA Fluke 5522A
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.04) Revised 01/20/2026 Page 9 of 17 Parameter/Range Frequency CMC2, 5 (±) Comments AC Current3 – Generate (cont) (33 to 330) mA (0.33 to 1.1) A (1.1 to 3) A (3 to 11) A (11 to 20.5) A (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 45 Hz to 1 kHz (1 to 5) kHz 45 Hz to 1 kHz (1 to 5) kHz 0.22 % + 20 µA 0.11 % + 20 µA 0.05 % + 20 µA 0.12 % + 50 µA 0.24 %+ 100 µA 0.48 %+ 200 µA 0.22 % + 100 µA 0.06 % + 100 µA 0.72 % + 1 mA 3 % + 5 mA 0.22 % + 100 µA 0.072 % + 100 µA 0.72 % + 1 mA 3 % + 5 mA 0.12 % + 2 mA 3.6 % + 2 mA 0.18 % + 5 mA 3.6 % + 5 mA Fluke 5522A AC Clamp-On Meters3 – Up to 150 A Toroidal Non-Toroidal (150 to 1025) A Toroidal Non-Toroidal (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz 0.49 % + 0.025 A 1 % + 0.027 A 0.76 % + 0.25 A 1.3 % + 0.25 A 0.49 % + 0.09 A 1 % + 0.1 A 0.76 % + 0.9 A 1.3 % + 0.9 A Fluke 5522A w/ 5500 coil AC Current – Measure3 (0 to 100) µA (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz 100 Hz to 5 kHz 0.4 % + 0.03 % of rng 0.15 % + 0.03 % of rng 0.06 % + 0.03 % of rng 0.06 % + 0.03 % of rng Agilent/HP 3458A
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.04) Revised 01/20/2026 Page 10 of 17 Parameter/Range Frequency CMC2, 5, 6 (±) Comments AC Current – Measure3 (cont) (0.1 to 100) mA 100 mA to 1 A (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (5 to 20) kHz (20 to 50) kHz (50 to 100) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (5 to 20) kHz (20 to 50) kHz 0.4 % + 0.02 % of rng 0.15 % + 0.02 % of rng 0.06 % + 0.02 % of rng 0.03 % + 0.02 % of rng 0.06 % + 0.02 % of rng 0.4 % + 0.04 % of rng 0.55 % + 0.15 % of rng 0.4 % + 0.02 % of rng 0.16 % + 0.02 % of rng 0.08 % + 0.02 % of rng 0.1 % + 0.02 % of rng 0.3 % + 0.02 % of rng 1 % + 0.04 % of rng Agilent/HP 3458A AC Power – Generate3 (45 to 65) Hz; PF=1 (33 to 330) mV Range (3.3 to 8.99) mA (9 to 32.99) mA (33 to 89.99) mA (90 to 329.99) mA (0.33 to 0.8999) A (0.9 to 2.1999) A (2.2 to 4.4999) A (4.5 to 20.5) A 330 mV to 1020 V Range (3.3 to 8.99) mA (9 to 32.99) mA (33 to 89.99) mA (90 to 329.99) mA (0.33 to 0.8999) A (0.9 to 2.1999) A (2.2 to 4.4999) A (4.5 to 20.5) A 110 µW to 3 mW (3 to 11) mW (1.1 to 30) mW (3 to 110) mW (11 to 300) mW (30 to 730) mW 73 mW to 1.5 W 150 mW to 6.8 W 1.1 mW to 9 W 3 mW to 33 W 11 mW to 90 W 30 mW to 330 W 110 mW to 900 W 300 mW to 2200 W 730 mW to 4500 W (1.5 to 20.9) kW 0.17 % 0.12 % 0.17 % 0.12 % 0.16 % 0.14 % 0.16 % 0.14 % 0.15 % 0.1 % 0.15 % 0.1 % 0.14 % 0.11 % 0.15 % 0.12 % Fluke 5522A
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.04) Revised 01/20/2026 Page 11 of 17 Parameter/Range Frequency CMC2, 5, 6 (±) Comments Oscilloscopes3 – Square Wave Signal: 50 Ω Load @ 1 kHz 1 MΩ Load @ 1 kHz DC Volt Amplitude: 50 Ω Load 1 MΩ Load Level Sine Wave: Frequency Amplitude 50 kHz Reference 50 kHz to 100 MHz (100 to 300) MHz (300 to 600) MHz (600 to 1100) MHz Flatness (Bandwidth) 0 kHz to 100 MHz (100 to 300) MHz (300 to 600) MHz (600 to 1100) MHz Time Markers: Into a 50 Ω Load Rise Time: 1 kHz to 2 MHz (2 to 10) MHz 1 mV to 6.6 V pk - pk 1 mV to 130 Vpk - pk (0 to 6.6) V (0 to 130) V (0 to 330) mV (0 to 3.3) V (0 to 33) V (30 to 330) V (100 to 1020) V (0 to 1100) MHz 5 mV to 5.5 V 5 mV to 5.5 V 5 mV to 5.5 V 5 mV to 5.5 V 4 mV to 3.5 V 5 mV to 5.5 V 5 mV to 5.5 V 5 mV to 5.5 V 4 mV to 3.5 V 5 s to 50 ms 20 ms to 1 ns ≤ 300 ps ≤ 350 ps 0.31 % + 40 µV 0.14 % + 40 µV 0.3 % + 40 µV 0.06 % + 40 µV 25 µV/V + 1 µV 14 µV/V + 2 µV 15 µV/V + 15 µV 22 µV/V + 150 µV 22 µV/V + 1.5 mV 3.3 µHz/Hz 2.4 % + 300 µV 4.2 % + 300 µV 4.8 % + 300 µV 7.2 % + 300 µV 8.4 % + 300 µV 1.8 % + 100 µV 2.4 % + 100 µV 4.8 % + 100 µV 6 % + 100 µV (30 + 1000t) µs/s 3.5 µs/s 130 ps 130 ps Fluke 5522A w/ SC1100 Fluke 5522A Fluke 5522A t = time in seconds Electrical Simulation of RTDs 3 Pt 385, 100 Ω (-200 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (630 to 800) °C 0.08 °C 0.10 °C 0.11 °C 0.13 °C 0.15 °C 0.28 °C Fluke 5522A
12

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.04) Revised 01/20/2026 Page 12 of 17 Parameter/Equipment Range CMC2 (±) Comments Electrical Thermocouple Simulation3 – Type B Type E Type J Type K Type N Type R Type S Type T Type J Type K Type T (600 to 800) °C (800 to 1820) °C (-250 to -100) °C (-100 to 650) °C (650 to 1000) °C (-210 to -100) °C (-100 to 760) °C (760 to 1200) °C (-200 to -100) °C (-100 to 1000) °C (1000 to 1372) °C (-200 to -100) °C (-100 to 410) °C (410 to 1300) °C (0 to 250) °C (250 to 1000) °C (1000 to 1767) °C (0 to 250) °C (250 to 1400) °C (1400 to 1767) °C (-250 to -150) °C (-150 to 0) °C (0 to 400) °C (-200 to 1200) °C (-200 to 1372) °C (-250 to 400) °C 0.54 °C 0.42 °C 0.61 °C 0.22 °C 0.28 °C 0.34 °C 0.23 °C 0.30 °C 0.41 °C 0.33 °C 0.49 °C 0.49 °C 0.29 °C 0.34 °C 0.70 °C 0.41 °C 0.49 °C 0.58 °C 0.46 °C 0.57 °C 0.76 °C 0.31 °C 0.22 °C 0.08 °C 0.08 °C 0.08 °C Fluke 5522A Fluke 5522A w/ice point reference
13ASTM Class 1; Class F weights-See scope document
14

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.04) Revised 01/20/2026 Page 14 of 17 Parameter/Equipment Range CMC2, 4, 6, 8 (±) Comments Torque Wrenches3 4 lbf∙in to 600 lbf∙ft 0.65 % CDI suretest 5000-ST Torque Testers3 4 lbf∙in to 600 lbf∙ft 0.065 % Class F weights & torque arms Rotary Torque – Measure3 Tools – Pneumatic, DC, Pulse (2.5 to 25) Nm (7.5 to 75) Nm (18 to 180) Nm 0.48 Nm 1.5 Nm 3.5 Nm Aimco torque analyzer w/ rotary transducers Speed/RPM/Rate3 – Simulation (2.5 to 100 000) RPM 0.004 % Agilent 33250A Speed/RPM/Rate3 – Non-Contact (6 to 60 000) RPM 0.02 % Monarch tachometer Totalize Meters3 – (Length Counters & Totalizers) Distance – Measure Up to 500 yards 0.51 % Shimpo tach w/ encoder wheel Pressure3 – Measuring Equipment Differential Absolute (0.025 to 0.25) inH 2O (0.25 to 0.5) inH2O (0.5 to 1) inH2O (1 to 10) inH 2O (10 to 25) inH2O Up to 16 psia 0.000 24 inH2O 0.000 59 inH2O 0.000 95 inH2O 0.0075 inH 2O 0.019 inH2O Greater of: 0.015 % or 0.006 % FS Heise HM2 Fluke 6270 w/PM500 modules
15

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.04) Revised 01/20/2026 Page 15 of 17 Parameter/Equipment Range CMC2, 4, 6, 8 (±) Comments Pressure3 – Measuring Equipment (cont) Pneumatic Hydraulic Up to 15 psi (-15 to 300) psi (300 to 1000) psi (1000 to 3000) psi (0.2 to 1000) psi (200 to 20 000) psi Greater of: 0.015 % or 0.006 % FS 0.015 % or 0.006 % FS 0.015 % or 0.006 % FS 0.015 % or 0.006 % FS 0.0084 % 0.021 % Fluke 6270 w/PM500 modules Ruska 2465-753 Fluke 3116 Barometric Pressure3 – Measuring Equipment (17 to 34) inHg 0.02 % Mensor CPG2300 Vacuum3 Down to 30 inHg 0.04 % FS Mensor CPG2500 Balancing machines3 Torque (5 to 30) ozf∙in 0.33 % Calibration Plate w/ Class F Weights VI. Thermodynamics Parameter/Equipment Range CMC2, 8 (±) Comments Humidity3 – Measure (10 to 95) % RH 1.5 % RH Vaisala HMP-233 Humidity3 – Measuring Devices (20 to 75) % RH 1.6 % RH Vaisala HMP-233 Temperature3 – Measuring Devices (-30 to 125) °C (50 to 400) °C (400 to 660) °C 0.06 °C 0.10 °C 0.33 °C Fluke 7103 w/PRT Fluke 9173 w/PRT Fluke 9173
16

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.04) Revised 01/20/2026 Page 16 of 17 Parameter/Equipment Range CMC2, 4, 6, 8 (±) Comments Temperature3 – Measure (0 to 100) °C (-200 to 300) °C (300 to 420) °C 0.04 °C 0.06 °C 0.08°C Fluke 1524 w/thermistor probe Fluke 1524 w/PRT probe Fluke 1529 w/5615 PRT probe Infrared Measuring Devices3 (-15 to 0) °C (0 to 120) °C 35 °C (35 to 100) °C (100 to 200) °C (200 to 350) °C (350 to 500) °C 0.61 °C 0.73 °C 0.84 °C 0.95 °C 1.2 °C 1.7 °C 2.3 °C Fluke 4180 Fluke 4181 ε = 0.95 λ= (8 to 14) µm VII. Time & Frequency Parameter/Equipment Range CMC2, 8 (±) Comments Frequency – Measuring Equipment3 (Up to 1100) MHz 3.3 µHz/Hz Fluke 5522A/1 GHz Frequency – Measure3 Up to 225 MHz 0.23 µHz/Hz HP 53131A Timers & Stop Watches3 (2 to 3600) s 0.1 s HP 53131A w/Agilent 33250A ____________________________________________ 1 This laboratory offers commercial and field calibration/dimensional testing services and is performed at the main laboratory and satellite laboratory listed. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration.
17

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.04) Revised 01/20/2026 Page 17 of 17 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches or millimeters depending upon CMC unit of measurement shown; R is the numerical value of the resolution of the device in its respective units; DL is the diagonal length of the device in inches; D is the numerical value of the nominal diameter of the device measured in inches or millimeters. 5 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as eith er a specific value that covers the full range or as a fraction/percentage of the reading plus a fixed floor specification. 6 In the statement of CMC a percentage refers to percent of reading unless otherwise noted. 7 This laboratory meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program for the types of dimensional tests listed above and is considered equivalent to that of a calibration. 8 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 9 This scope meets A2LA’s P112 Flexible Scope Policy.
18ISO/IEC 17025:2017; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

1200 Woodruff Road, Suite A-19, Greenville, SC, 29607, US

34.85135, -82.39849

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.