Smithers
Building F, 45 Chunxing Road, Phase II Plainvim Industry Park, Jiangsu , 215143, People's Republic of China, Jiangsu, China
Visit website- Accredited standards
- 9
- A2LA certificate
- 1
- Sites in our directory
- 3
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 9 standard numbers and the 4 official names we hold. When no standard matches, it searches the method text of every scope line.
ASTM F414
ASTM F551
ASTM F1112
ASTM F1502
ASTM F2838
ISO 16392Tyres - Electrical resistance - Test method for measuring electrical resistance of tyres on a test rig
ISO 17269Passenger car tyres - Methods for measuring rolling circumference - Loaded new tyres
ISO 18164Motorcycle tyres rolling resistance measurement methods - Single point test
ISO 28580Passenger car, truck and bus tyre rolling resistance measurement method - Single point test and correlation of measurement results
FMVSS 109; FMVSS 119; FMVSS 139; CMVSS 109; CMVSS 119; CMVSS 139; SAE J918C; ASTM F551; UNECE R30; UNECE R54; UNECE R108; UNECE R109; CETP 04.04-E-3281; GB 9743; GB 9744; GB/T 4501; GB/T 4502; GB/T 38510; GB/T 30196; GSO 53; GSO 646; INMETRO Nº 379; SAE J1561; ASTM F414; GSO 647
FMVSS 109; FMVSS 139; CMVSS 109; CMVSS 139; SAE J918C; GB 9743; GB/T 4502; GSO 53; SAE J267; SAE J1204; SAE J328; SAE J2530; GB/T 5334; GB/T 5909; UNECE R124; CETP 04.04-E-300; DTAP; GB/T 37259; ASTM F2838; CVTC 33036; SAE J175; GB/T 15704; ASTM F1112; GMW15000; CVTC 33222; GB/T 40716; GB/T 38510; FMVSS 119; ASTM F1502; UNECE R30; UNECE R54; UNECE R108; UNECE R109; GMW14997; GMW14998; GMW15004; GB 9744; GB/T 521; GSO 646; INMETRO Nº 379; SAE J1269; SAE J2452; ISO 18164; ISO 28580; GMW14996; UNECE R117; GB/T 29040; GB/T 29042; GB/T 18861; GMW14999; ISO 17269; ISO 16392; GB/T 26277
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
3 lines
ISO/IEC 17025
Active363.05
The scope document we hold says it is valid until 2027-11-30.
Accredited scope, certificate 363.05
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | FMVSS 109; FMVSS 119; FMVSS 139; CMVSS 109; CMVSS 119; CMVSS 139; SAE J918C; ASTM F551; UNECE R30; UNECE R54; UNECE R108; UNECE R109; CETP 04.04-E-3281; GB 9743; GB 9744; GB/T 4501; GB/T 4502; GB/T 38510; GB/T 30196; GSO 53; GSO 646; INMETRO Nº 379; SAE J1561; ASTM F414; GSO 647 | vehicles and automotive components and systems, and rubber products | - |
| 2 | FMVSS 109; FMVSS 139; CMVSS 109; CMVSS 139; SAE J918C; GB 9743; GB/T 4502; GSO 53; SAE J267; SAE J1204; SAE J328; SAE J2530; GB/T 5334; GB/T 5909; UNECE R124; CETP 04.04-E-300; DTAP; GB/T 37259; ASTM F2838; CVTC 33036; SAE J175; GB/T 15704; ASTM F1112; GMW15000; CVTC 33222; GB/T 40716; GB/T 38510; FMVSS 119; ASTM F1502; UNECE R30; UNECE R54; UNECE R108; UNECE R109; GMW14997; GMW14998; GMW15004; GB 9744; GB/T 521; GSO 646; INMETRO Nº 379; SAE J1269; SAE J2452; ISO 18164; ISO 28580; GMW14996; UNECE R117; GB/T 29040; GB/T 29042; GB/T 18861; GMW14999; ISO 17269; ISO 16392; GB/T 26277 | tire; wheel | - |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
SMITHERS
Jiangsu, People’s Repoublic of China
for technical competence in the field of
Mechanical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 18th day of November 2025.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 0363.05
Valid to November 30, 2027 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.