ASSA ABLOY Opening Solutions Sweden
Kungsgatan 73 C, 632 21, Eskilstuna, Sweden
- Accredited standards
- 13
- SWEDAC certificates
- 2
- Site in our directory
- 1
What this lab is accredited for
Our reading of the SWEDAC scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 13 standard numbers and the 4 official names we hold. When no standard matches, it searches the method text of every scope line.
EN9
EN 179
EN 1125
EN 1303
EN 1670
EN 1906
EN 1935
EN 12209
EN 14846
EN 15684
IEC 60068 series3
IEC 60068-2-1Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 60068-2-2Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 60068-2-30Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
Other standards1
ISO 9227Corrosion tests in artificial atmospheres - Salt spray tests
SS-EN ISO/IEC 17025:2018 ASSA ABLOY Opening Solutions Sweden AB Eskilstuna Ackrediteringsnummer 1600 ATL; SS-EN 1125 Funktion Byggnadsbeslag Ja 2 Nej Section excluded: Fire Resistance and testing of double doors SS-EN 12209 Funktion Byggnadsbeslag Ja 2 Nej Section excluded: Fire Resistance SS-EN 1303 Funktion Byggnadsbeslag Ja 2 Nej Section excluded: Fire Resistance SS-EN 14846 Funktion Byggnadsbeslag Ja 2 Nej Section excluded: 6:10 Security - Electrical manipulation tests and Annex A; SS-EN 15684 Funktion Byggnadsbeslag Ja 2 Nej Section excluded: 4; SS-EN 179 Funktion Byggnadsbeslag Ja 2 Nej Section excluded: Fire Resistance SS-EN 1906 Funktion Byggnadsbeslag Ja 2 Nej Section excluded: Fire Resistance SS-EN 1935 Funktion Byggnadsbeslag Ja 2 Nej Section excluded: Fire Resistance and Shear strength SSF 1090 Funktion Byggnadsbeslag Ja 2 Nej Section excluded: Manipulation SSF 1091 Funktion Byggnadsbeslag Ja 2 Nej Section excluded: manipulation; ISO/IEC 17025:2018 ASSA ABLOY Opening Solutions Sweden AB Eskilstuna Ackrediteringsnummer 1600
SS-EN ISO/IEC 17025:2018; SS 3523; SS-EN 1125; SS-EN 12209; SS-EN 1303; SS-EN 14846; SS-EN 15684; SS-EN 179; SS-EN 1906; SS-EN 1935; SSF 1090; SSF 1091; SSF 1092; SSF 1093; SSF 1094; SSF 1095
SS-EN 1670 Korrosionsmotst; SS-EN ISO 9227 Saltdimma Ytskydd Ja 2 Nej Section excluded: AASS test och CASS test Klimat- och milj; SS-EN 60068-2-1 K; SS-EN 60068-2-2 V; SS-EN 60068-2-30 Fukt och temperaturbest
SSF 1096; SS-EN 1670; SS-EN ISO 9227; SS-EN 60068-2-1; SS-EN 60068-2-2; SS-EN 60068-2-30
Read from the scope as published by SWEDAC. Register refreshed 2026-11-08.
Scope as published by SWEDAC
4 lines
ISO/IEC 17025
Activea000472-001
Accredited scope, certificate a000472-001
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | SS-EN ISO/IEC 17025:2018 ASSA ABLOY Opening Solutions Sweden AB Eskilstuna Ackrediteringsnummer 1600 ATL; SS-EN 1125 Funktion Byggnadsbeslag Ja 2 Nej Section excluded: Fire Resistance and testing of double doors SS-EN 12209 Funktion Byggnadsbeslag Ja 2 Nej Section excluded: Fire Resistance SS-EN 1303 Funktion Byggnadsbeslag Ja 2 Nej Section excluded: Fire Resistance SS-EN 14846 Funktion Byggnadsbeslag Ja 2 Nej Section excluded: 6:10 Security - Electrical manipulation tests and Annex A; SS-EN 15684 Funktion Byggnadsbeslag Ja 2 Nej Section excluded: 4; SS-EN 179 Funktion Byggnadsbeslag Ja 2 Nej Section excluded: Fire Resistance SS-EN 1906 Funktion Byggnadsbeslag Ja 2 Nej Section excluded: Fire Resistance SS-EN 1935 Funktion Byggnadsbeslag Ja 2 Nej Section excluded: Fire Resistance and Shear strength SSF 1090 Funktion Byggnadsbeslag Ja 2 Nej Section excluded: Manipulation SSF 1091 Funktion Byggnadsbeslag Ja 2 Nej Section excluded: manipulation; ISO/IEC 17025:2018 ASSA ABLOY Opening Solutions Sweden AB Eskilstuna Ackrediteringsnummer 1600 | Byggnadsbeslag | - |
| 2 | SS-EN 1670 Korrosionsmotst; SS-EN ISO 9227 Saltdimma Ytskydd Ja 2 Nej Section excluded: AASS test och CASS test Klimat- och milj; SS-EN 60068-2-1 K; SS-EN 60068-2-2 V; SS-EN 60068-2-30 Fukt och temperaturbest | Byggnadsbeslag; Ytskydd | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
ISO/IEC 17025
ActiveA000472-001
Accredited scope, certificate A000472-001
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | SS-EN ISO/IEC 17025:2018; SS 3523; SS-EN 1125; SS-EN 12209; SS-EN 1303; SS-EN 14846; SS-EN 15684; SS-EN 179; SS-EN 1906; SS-EN 1935; SSF 1090; SSF 1091; SSF 1092; SSF 1093; SSF 1094; SSF 1095 | Byggnadsbeslag | - |
| 2 | SSF 1096; SS-EN 1670; SS-EN ISO 9227; SS-EN 60068-2-1; SS-EN 60068-2-2; SS-EN 60068-2-30 | Byggnadsbeslag; Ytskydd | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Sweden
Accreditation data refreshed from the SWEDAC register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the SWEDAC entry linked above.