Eaton-Aerospace Test Facilities
2880 West Argyle St., 49202, Jackson, MI, United States
Visit website- Accredited standards
- 3
- A2LA certificate
- 1
- Sites in our directory
- 2
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 3 standard numbers and the 2 official names we hold. When no standard matches, it searches the method text of every scope line.
ASTM D380
ISO 2685Aircraft - Environmental test procedure for airborne equipment - Resistance to fire in designated fire zones
ISO 10583Aerospace fluid systems - Test methods for fitting on tube assemblies
RTCA/DO 160G; ARP1616; SAE AS604; SAE AS614; AS1339; AS1975; AS2078; SAE AS1709; MIL-DTL-5513; MIL-STD-810G; SAE AS1650; SAE AS1895; SAE AS1960; SAE AS4751; ASTM D380
SAE AS1709; ARP1616; MIL-DTL-5513; SAE AS604; SAE AS614; SAE AS620; SAE AS1227; SAE AS1339; SAE AS1975; ATP2001-15260B; AIR1377; ISO 2685; Boeing SCD-S781Z004; SAE AS 7510; RTCA/DO 160G (sec. 11); Eaton-ACES 1563; SAE AS2078; MIL-STD-202G; ABS2338; ETR-49160-L101 (sec.6.12)
SAE AS620; AS1227; ATP2001-15260B; SAE AS604; AS614; AS1339; AS1975; AS2078; ARP1616; SAE AS1709; MIL-DTL-5513; ARP1383; SAE AS603; MIL-DTL-5513; ISO 10583; ARP908; ARP1185; MIL-STD-810G
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
5 lines
ISO/IEC 17025
Active2024.01
The scope document we hold says it is valid until 2027-03-31.
Accredited scope, certificate 2024.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | SAE AS604; SAE AS614; SAE AS620F; SAE AS1227; SAE AS1339; SAE AS1975; SAE AS1709; SAE AS1650; SAE AS2078; ATP2001-15260B; ARP1616; MIL-STD-202G; ABS2338; MIL-DTL-5513; SAE AS7510 | aerospace and automotive hoses, couplings, fittings and assemblies; electrical power distribution systems, motors, and invertors | - |
| 2 | SAE AS1709; ARP1616; MIL-DTL-5513; SAE AS604; SAE AS614; SAE AS620; SAE AS1227; SAE AS1339; SAE AS1975; ATP2001-15260B; AIR1377; ISO 2685; Boeing SCD-S781Z004; SAE AS 7510; RTCA/DO 160G (sec. 11); Eaton-ACES 1563; SAE AS2078; MIL-STD-202G; ABS2338; ETR-49160-L101 (sec.6.12) | Product | - |
| 3 | SAE AS620; AS1227; ATP2001-15260B; SAE AS604; AS614; AS1339; AS1975; AS2078; ARP1616; SAE AS1709; MIL-DTL-5513; ARP1383; SAE AS603; MIL-DTL-5513; ISO 10583; ARP908; ARP1185; MIL-STD-810G | - | - |
| 4 | RTCA/DO 160G; ARP1616; SAE AS604; SAE AS614; AS1339; AS1975; AS2078; SAE AS1709; MIL-DTL-5513; MIL-STD-810G; SAE AS1650; SAE AS1895; SAE AS1960; SAE AS4751; ASTM D380 | - | - |
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
EATON-AEROSPACE TEST FACILITIES
Jackson, MI
for technical competence in the field of
Mechanical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 21st day of April 2025.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 2024.01
Valid to March 31, 2027 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Other Locations
1 other site in this organization
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.