SIRIM QAS INTERNATIONAL SDN BHD

RFEMC Testing Section, SIRIM QAS International Sdn Bhd c/o Penang Skills Development Center, 1, Jalan Sultan Azlan Shah, Bandar Bayan Baru, Penang, Malaysia, Penang, Malaysia

Visit website
A2LA 7755.01ISO/IEC 17025Register refreshed 2026-10-23

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
23
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 23 standard numbers and the 20 official names we hold. When no standard matches, it searches the method text of every scope line.

IEC 61000 series11
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test

Certificate says EN 61000-4-2. Probably the same standard; not checked against the EN document.

IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test

Certificate says EN 61000-4-3. Probably the same standard; not checked against the EN document.

IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments+1 national

National versions in the same scope

AS/NZS 61000.6.3national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 61000-6-3. Probably the same standard; not checked against the EN document.

IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments+1 national

National versions in the same scope

AS/NZS 61000.6.4identical to it

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

CISPR4
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement+1 national

National versions in the same scope

AS/NZS CISPR 11national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55011. Probably the same standard; not checked against the EN document.

CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission+1 national

National versions in the same scope

AS/NZS CISPR 14.1national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55014-1, IEC 55014-1. Probably the same standard; not checked against the EN document.

CISPR 15Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment+1 national

National versions in the same scope

AS/NZS CISPR 15national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55015, IEC 55015. Probably the same standard; not checked against the EN document.

CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+1 national

National versions in the same scope

AS/NZS CISPR 32identical to it

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55032. Probably the same standard; not checked against the EN document.

ETSI4
ETSI EN 300 220-1
ETSI EN 300 328Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz band; Harmonised Standard for access to radio spectrum
ETSI EN 300 440
ETSI EN 301 893
IEC3
IEC 60601-1-2Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
IEC 61326-2-6Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-6: Particular requirements - In vitro diagnostic (IVD) medical electrical equipment
Other standards1
ISO 11452-4Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 4: Harness excitation methods

Read from the A2LA scope document we downloaded on 2026-08-05. Register refreshed 2026-10-23.

Scope as published by A2LA

3 lines
A2LA

ISO/IEC 17025

Active

7755.01

The scope document we hold says it is valid until 2028-06-30.

View scope

Accredited scope, certificate 7755.01

LineMethodMatrixRange
1CISPR 11; EN 55011; AS/NZS CISPR 11; BS EN 55011; CISPR 14-1; EN 55014-1; EN IEC 55014-1; AS/NZS CISPR 14.1; AS/NZS CISPR 14.1; J 55014-1; BS EN 55014-1; BS EN IEC 55014-1; CISPR 15; EN IEC 55015; AS/NZS CISPR 15; J 55015; BS EN 55015; BS EN IEC 55015; CISPR 32; EN 55032; AS/NZS CISPR 32; J55032; BS EN 55032; IEC 61000-6-3; EN 61000-6-3; EN IEC 61000-6-3; AS/NZS 61000.6.3; BS EN 61000-6-3; BS EN IEC 61000-6-3; IEC 61000-6-4; EN 61000-6-4; EN IEC 61000-6-4; BS EN 61000-6-4; BS EN IEC 61000-6-4; AS/NZS 61000.6.4; IEC 61000-3-2; EN IEC 61000-3-2; BS EN IEC 61000-3-2; IEC 61000-3-3; EN 61000-3-3; BS EN 61000-3-3; ISO/IEC 17025:2017--
2EN 61000-4-2; IEC 61000-4-2; IEC 61000-4-3; EN IEC 61000-4-3; BS EN IEC 61000-4-3; IEC 61000-4-4; EN 61000-4-4; BS EN 61000-4-4; IEC 61000-4-5; EN 61000-4-5; BS EN 61000-4-5; IEC 61000-4-6; EN 61000-4-6; BS EN 61000-4-6; EN IEC 61000-4-6; BS EN IEC 61000-4-6; IEC 61000-4-8; EN 61000-4-8; BS EN 61000-4-8; IEC 61000-4-11; EN 61000-4-11; EN IEC 61000-4-11; BS EN 61000-4-11; BS EN IEC 61000-4-11; IEC 60601-1-2; IEC 61326-1; IEC 61326-2-6; ETSI EN 300 328; ETSI EN 301 893; ETSI EN 300 440; ETSI EN 300 220-1; ISO 11452-4--
3ISO/IEC 17025:2017--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

RFEMC Testing Section, SIRIM QAS International Sdn Bhd c/o Penang Skills Development Center, 1, Jalan Sultan Azlan Shah, Bandar Bayan Baru, Penang, Malaysia, Penang, MY

39.95407, -75.15606

Open in Maps

Accreditation data refreshed from the A2LA register on .