Registers refreshed 2026-11-20.See refresh dates
Germany

Medizinisches Versorgungszentrum für Labordiagnostik und Mikrobiologie Rhein-Main

Hans-Böckler-Straße 1-3, 68161, Mannheim, Germany

DAKKS D-PL-18008-01-00DAKKS D-PL-18008-01-01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
6
DAKKS certificates
2
Site in our directory
1
DAKKS accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 6 scope lines.

DAKKS certificate D-PL-18008-01-00 · 4 lines

LineMethodMatrixRange
1DIN EN ISO/IEC 17025:2018--
2

Extracted from the scope document; tables may not line up. View scope for the original.

Anlage zur Akkreditierungsurkunde D-PL-18008-01-00 Prüfungen im Bereich: Gesundheitsversorgung (Medizinische Laboratoriumsuntersuchungen im Rahmen klinischer Studien) Diese Urkundenanlage gilt nur zusammen mit der schriftlich erteilten Urkunde und gibt den Stand zum Zeitpunkt des Ausstellungsdatums wieder. Der jeweils aktuelle Stand der gültigen und überwachten Akkreditierung ist der Datenbank akkreditierter Stellen der Deutschen Akkreditierungsstelle zu entnehmen (www.dakks.de) Verwendete Abkürzungen: siehe letzte Seite Innerhalb der mit * gekennzeichneten Prüfbereiche ist dem Prüflaboratorium, ohne dass es einer vorherigen Information und Zustimmung der DAkkS bedarf, die freie Auswahl von genormten oder ihnen gleichzusetzenden Prüfverfahren gestattet. Innerhalb der mit ** gekennzeichneten Prüfbereiche ist dem Prüflaboratorium, ohne dass es einer vorherigen Information und Zustimmung der DAkkS GmbH bedarf, die Modifizierung sowie Weiter- und Neuentwicklung von Prüfverfahren gestattet. Die aufgeführten Prüfverfahren sind beispielhaft. Das Prüflaboratorium verfügt über eine aktuelle Liste aller Prüfverfahren im flexiblen Akkreditierungsbereich. Gültig ab: 16.05.2024 Ausstellungsdatum: 16.05.2024 Seite 2 von 4
3-EDTA-Vollblut; Knochenmark; EDTA-Vollblut, Knochenmark; EDTA-Vollblut
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

Anlage zur Akkreditierungsurkunde D-PL-18008-01-00 Prüfgebiet: Klinische Chemie Prüfart: Analyt (Messgröße) Prüfmaterial (Matrix) Prüftechnik Differentialblutbild (maschinell) EDTA-Vollblut Durchflusszytometrie Kleines Blutbild (maschinell) EDTA-Vollblut, Knochenmark Durchflusszytometrie Retikulozyten EDTA-Vollblut Durchflusszytometrie Prüfgebiet: Immunologie Prüfart: Analyt (Messgröße) Prüfmaterial (Matrix) Prüftechnik MRD CLL: M-2018-322 MB- CART19.1 rr_BCM Studie EDTA-Vollblut, Knochenmark Durchflusszytometrie CAR T cell Persistence and Phenotype (Secondary endpoint): M-2016-312 MB-CART20.1 Lymphoma EDTA-Vollblut Durchflusszytometrie Immunophenotyping (Exploratory endpoint): M-2016- 312 MB-CART20.1 Lymphoma EDTA-Vollblut Durchflusszytometrie CAR T cell Persistence and Phenotype (Secondary endpoint):M-2018-322 MB- CART19.1 rr_BCM Studie EDTA-Vollblut Durchflusszytometrie Immunophenotyping (Exploratory endpoint): M-2018- 322 MB-CART19.1 rr_BCM Studie EDTA-Vollblut Durchflusszytometrie CAR T cell Persistence and Phenotype (Secondary endpoint): M-2019-331 MB-CART2019.1 Lymphoma (DALY1) EDTA-Vollblut Durchflusszytometrie Gesundheitsversorgung (Medizinische Laboratoriumsuntersuchungen im Rahmen klinischer Studien) Durchflusszytometrie (Partikeleigenschaftsbestimmungen)* Durchflusszytometrie** Gültig ab: 16.05.2024 Ausstellungsdatum: 16.05.2024 Seite 3 von 4
-
4ISO International Organization for Standardization Gültig ab: 16EDTA-Vollblut; EDTA-Vollblut; EDTA-Vollblut-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

DAKKS certificate D-PL-18008-01-01 · 2 lines

LineMethodMatrixRange
1DIN EN ISO/IEC 17025:2018--
2-EDTA -Vollblut; Knochenmark
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

Anlage zur Akkreditierungsurkunde D-PL-18008-01-01 Gültig ab: 24.09.2026 Ausstellungsdatum: 24.09.2026 Seite 2 von 2 Flexibler Akkreditierungsbereich: Dem Prüflaboratorium ist innerhalb der gekennzeichneten Prüfbereiche, ohne dass es einer vorherigen Information und Zustimmung der DAkkS bedarf, [Flex B] die freie Auswahl von genormten oder ihnen gleichzusetzenden Prüfverfahren gestattet. [Flex C] die Modifizierung sowie Weiter- und Neuent wicklung von Prüfverfahren gestattet. Das Prüflaboratorium verfügt über eine aktuelle Liste aller Prüfverfahren im flexiblen Akkreditierungsbereich. Die Liste ist öffentlich verfügbar auf der Webpräsenz des Prüflaboratoriums. 1 Medizinische Laboratoriumsuntersuchungen im Rahmen klinischer Studien 1.1 Klinische Chemie Durchflusszytometrie Scope- Nr. Prüfgegenstand Messgröße Prüfparameter Analyt Prüfart Prüfmethodik/Messprinzip Flexibili- sierung 1.1.1.1 EDTA -Vollblut Differentialblutbild (maschinell) Durchflusszytometrie Flex B 1.1.1.2 EDTA -Vollblut Kleines Blutbild (maschinell) Durchflusszytometrie Flex B 1.1.1.3 EDTA -Vollblut Retikulozyten Durchflusszytometrie Flex B 1.2 Immunologie Durchflusszytometrie Scope- Nr. Prüfgegenstand Messgröße Prüfparameter Analyt Prüfart Prüfmethodik/Messprinzip Flexibili- sierung 1.2.1.1 EDTA -Vollblut, Knochenmark CD 19+ B -Zellen (% Leukozyten) MRD CLL Durchflusszytometrie Flex C 1.2.1.2 EDTA -Vollblut CAR -T Zellen (% CD3+ T-Zellen) Durchflusszytometrie Flex C 1.2.1.3 EDTA -Vollblut viable CD3+ Zellen (count/µl) Durchflusszytometrie Flex C Verwendete Abkürzungen: DIN Deutsches Institut für Normung e.V. EN Europäische Norm IEC International Electrotechnical Commission – Int ernationale Elektrotechnische Kommission ISO International Organization for Standardization – Internationale Organisation für Normung
-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Hans-Böckler-Straße 1-3, Mannheim, 68161, DE

49.49142, 8.47522

Open in Maps

Accreditation data refreshed from the DAKKS register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.