Accredited standards
55
RvA certificate
1
Site in our directory
1
RvA accredited scope

What this lab is accredited for

Our reading of the RvA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 55 standard numbers and the 8 official names we hold. When no standard matches, it searches the method text of every scope line.

EN39
EN 410
EN 572-2
EN 572-9
EN 673
EN 1026
EN 1027
EN 1036-1
EN 1036-2
EN 1051-2
EN 1288-3
EN 1364-1
EN 1627
Show all 39
EN 1628
EN 1629
EN 1630
EN 1748-1-2
EN 1748-2-2
EN 1863-1
EN 1863-2
EN 12150-1
EN 12150-2
EN 12211
EN 12337-2
EN 12600
EN 12898
EN 13024-1
EN 13024-2
EN 14041
EN 14178-2
EN 14179-1
EN 14179-2
EN 14321-1
EN 14321-2
EN 14351-1
EN 14904
EN 15682-1
EN 15682-2
EN 15683-1
EN 15683-2
ISO 12543 series6
ISO 12543-1Glass in building - Laminated glass and laminated safety glass - Part 1: Vocabulary and description of component parts
ISO 12543-2Glass in building - Laminated glass and laminated safety glass - Part 2: Laminated safety glass
ISO 12543-3Glass in building - Laminated glass and laminated safety glass - Part 3: Laminated glass
ISO 12543-4Glass in building - Laminated glass and laminated safety glass - Part 4: Test methods for durability
ISO 12543-5Glass in building - Laminated glass and laminated safety glass - Part 5: Dimensions and edge finishing
ISO 12543-6Glass in building - Laminated glass and laminated safety glass - Part 6: Appearance
EN 1279 series5
EN 1279-2
EN 1279-3
EN 1279-4
EN 1279-5
EN 1279-6
EN 1096 series3
EN 1096-2
EN 1096-3
EN 1096-4
Other standards2
ISO 10077-1Thermal performance of windows, doors and shutters - Calculation of thermal transmittance - Part 1: General
ISO 10077-2Thermal performance of windows, doors and shutters - Calculation of thermal transmittance - Part 2: Numerical method for frames

Read from the RvA scope document we downloaded on 2026-02-12. Register refreshed 2026-11-15.

Scope as published by RvA

8 lines
RvA

ISO/IEC 17025

Active

L484

The scope document we hold says it is valid until 2029-05-01.

View scope

Accredited scope, certificate L484

LineMethodMatrixRange
1EN ISO/IEC 17025:2017; ECE R43Automotive Glass & Plastic Panels; Flat or curved automotive glas, glass/plastic or plastic panes-
2PAS24; EN 1628; EN 1627; EN 1629; EN 1630; EN 12211; EN 1027; EN 1026Ball drop; Pedestrian doorsets and windows; Pedestrian doorsets/ Windows/curtain walling/grilles shutters; Windows/Doors-
3EN 410 EN 673 EN ISO 10077-1 EN ISO 10077-2Drawing of windows and doors-
4EN ISO/IEC 17025:2017; EN 572-2; EN 673; EN 1279-2; EN 1279-3; EN 1279-4; EN 1279-6; EN 12600; EN 1288-3; EN 12898; EN 1863-1; EN 12150-1; EN 14179-1; EN 14321-1; EN 13024-1; EN 15682-1; EN 15683-1; EN 1096-2; EN 1096-3; EN-ISO 12543-1; EN-ISO 12543-2; EN-ISO 12543-3; EN-ISO 12543-4; EN-ISO 12543-5; EN-ISO 12543-6; EN 1036-1--
5EN 1036-1Glass-
6EN ISO/IEC 17025:2017; EN 14351-1:2006+A2:2016; EN 14041:2004; EN 14041:2004/AC:2006; EN 14904:2006; EN 572-9:2004; EN 1096-4:2018; EN 1051-2:2007; EN 1279-5:2018; EN 1748-1-2:2004; EN 1748-2-2:2004; EN 1863-2:2004; EN 12150-2:2004; EN 12337-2:2004; EN 14178-2:2004; EN 14179-2:2005; EN 14321-2:2005; EN 13024-2:2004; EN 15682-2:2013; EN 15683-2:2013Doors, windows, shutters, blinds, gates and related building hardware; Floorings; Resilient and textile floorings (for internal uses); Rigid flooring products: Floor screed materials; Flat glass, profiled glass, glass-block products and Insulating glass units; Flat glass, profiled glass (for use in a glazed assembly intended specifically to provide fire resistance)-
7EN 572-9:2004; EN 1096-4:2018; EN 1051-2:2007; EN 1279-5:2018; EN 1748-1-2:2004; EN 1748-2-2:2004; EN 1863-2:2004; EN 12150-2:2004; EN 12337-2:2004; EN 14178-2:2004; EN 14179-2:2005; EN 14321-2:2005; EN 13024-2:2004; EN 15682-2:2013; EN 15683-2:2013; EN 1036-2Flat glass, profiled glass, glass-block products and Insulating glass units-
8EN 572-9:2004; EN 1096-4:2018; EN 1051-2:2007; EN 1279-5:2018; EN 1748-1-2:2004; EN 1748-2-2:2004; EN 1863-2:2004; EN 12150-2:2004; EN 12337-2:2004; EN 14178-2:2004; EN 14179-2:2005; EN 14321-2:2005; EN 13024-2:2004; EN 15682-2:2013; EN 15683-2:2013; EN 1364-1Flat glass, profiled glass, glass-block products and Insulating glass units-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Westervoortsedijk 73, ARNHEM, 6827 AV, NL

51.96876, 5.94053

Open in Maps

Accreditation data refreshed from the RvA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the RvA entry linked above.