FindTestingLabs
Registers refreshed 2026-09-25.See refresh dates
France

CRITT MATÉRIAUX INNOVATION - NOGENT

RUE LAVOISIER POLE TECHNOLOGIQUE DE HAUTE CHAMPAGNE, 52800, NOGENT, France

COFRAC|1-1648ISO/IEC 17025Register refreshed 2026-09-25
Certificates
1
Scope items
13
Standards
46
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at CRITT MATÉRIAUX INNOVATION - NOGENT?

Claim this profile to keep it accurate.

Register record

COFRACRefreshed
1-1648Active

Accredited standards

46

Our reading of the COFRAC scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.

ASTM

ASTM A967Name not checked yet
As written on the certificate · Line 12 (COFRAC 1-1648)

ASTM A967 / A967M; ASTM A967-17; ASTM F1089; ASTM F1089-18; ASTM F1854

ASTM E8Standard Test Methods for Tension Testing of Metallic Materials
As written on the certificate · Line 2 (COFRAC 1-1648)

NF EN ISO 6892-1; ASTM E8/8M; ASTM E407; NF A 05-150; DMC 0090; NF EN ISO 643; NF A 04-503; NF A 04-505; NF EN ISO 2624; ASTM E112; ISO 4967; ASTM E45; SAE AMS 2315; NF EN 2003-009; PR 6110

As written on the certificate · Line 5 (COFRAC 1-1648)

ISO 5832-1; ISO 6892-1; ASTM E8/E8M; ASTM F138; ASTM F139; ISO 5832-2; ASTM F67; ISO 5832-3; ASTM F136; ISO 5832-4; ISO 5832-5; ISO 5832-6; ASTM F562; ISO 5832-7; NF S 94-057; ASTM F1058; ISO 5832-8; ISO 5832-9; ASTM F1586; ISO 5832-10; ISO 5832-11; ASTM F1295; ISO 5832-12; ASTM F1537; ASTM F799; ASTM F90

ASTM E45Standard Test Methods for Determining the Inclusion Content of Steel
As written on the certificate · Line 2 (COFRAC 1-1648)

NF EN ISO 6892-1; ASTM E8/8M; ASTM E407; NF A 05-150; DMC 0090; NF EN ISO 643; NF A 04-503; NF A 04-505; NF EN ISO 2624; ASTM E112; ISO 4967; ASTM E45; SAE AMS 2315; NF EN 2003-009; PR 6110

As written on the certificate · Line 8 (COFRAC 1-1648)

ISO 643; ISO 4967; NF A 05-150; ASTM E407; ASTM E112; ASTM E45 A

As written on the certificate · Line 11 (COFRAC 1-1648)

ISO 5832-6; ISO 643; ASTM E112; ASTM F562; ISO 5832-8 (1997) *; ISO 5832-12; ASTM F1537; ASTM F799; ASTM F90; ASTM E45 A; ASTM F1058; ISO 5832-7; ISO 4967; NF S 94-057 (1997) *; ISO 5832-5; ISO 5832-4; NF A 05-150; ASTM E407

ASTM E112Standard Test Methods for Determining Average Grain Size
As written on the certificate · Line 2 (COFRAC 1-1648)

NF EN ISO 6892-1; ASTM E8/8M; ASTM E407; NF A 05-150; DMC 0090; NF EN ISO 643; NF A 04-503; NF A 04-505; NF EN ISO 2624; ASTM E112; ISO 4967; ASTM E45; SAE AMS 2315; NF EN 2003-009; PR 6110

As written on the certificate · Line 8 (COFRAC 1-1648)

ISO 643; ISO 4967; NF A 05-150; ASTM E407; ASTM E112; ASTM E45 A

As written on the certificate · Line 9 (COFRAC 1-1648)

ISO 643; ASTM E112; ASTM E407; ASTM F67; ISO 5832-2

As written on the certificate · Line 11 (COFRAC 1-1648)

ISO 5832-6; ISO 643; ASTM E112; ASTM F562; ISO 5832-8 (1997) *; ISO 5832-12; ASTM F1537; ASTM F799; ASTM F90; ASTM E45 A; ASTM F1058; ISO 5832-7; ISO 4967; NF S 94-057 (1997) *; ISO 5832-5; ISO 5832-4; NF A 05-150; ASTM E407

ASTM E407Standard Practice for Microetching Metals and Alloys
As written on the certificate · Line 2 (COFRAC 1-1648)

NF EN ISO 6892-1; ASTM E8/8M; ASTM E407; NF A 05-150; DMC 0090; NF EN ISO 643; NF A 04-503; NF A 04-505; NF EN ISO 2624; ASTM E112; ISO 4967; ASTM E45; SAE AMS 2315; NF EN 2003-009; PR 6110

As written on the certificate · Line 8 (COFRAC 1-1648)

ISO 643; ISO 4967; NF A 05-150; ASTM E407; ASTM E112; ASTM E45 A

As written on the certificate · Line 9 (COFRAC 1-1648)

ISO 643; ASTM E112; ASTM E407; ASTM F67; ISO 5832-2

As written on the certificate · Line 10 (COFRAC 1-1648)

ISO 5832-3; NF A 05-150; ASTM E407; ISO 20160; EN 3114-003; ETTC2; ETTC4; ISO 5832-10; ISO 5832-11; ASTM F136; ASTM F1295; NF S 94-080-1; NF S 94-080-2; EN 3114-003; ETTC4; NF S 94-080-3; NF S 94-080-3; NF S 94-080-4; ISO 20160; EN 3114-002; EN 3114-003; ETTC2/ ETTC4; NF S 94-081-1; ISO 20160; EN 3114-002; ETTC2; NF S 94-081-2; ISO 20160; EN 3114-002; ETTC2

As written on the certificate · Line 11 (COFRAC 1-1648)

ISO 5832-6; ISO 643; ASTM E112; ASTM F562; ISO 5832-8 (1997) *; ISO 5832-12; ASTM F1537; ASTM F799; ASTM F90; ASTM E45 A; ASTM F1058; ISO 5832-7; ISO 4967; NF S 94-057 (1997) *; ISO 5832-5; ISO 5832-4; NF A 05-150; ASTM E407

ASTM E2371Name not checked yet
As written on the certificate · Line 3 (COFRAC 1-1648)

NF EN 3114-001; NF EN 3114-002; NF EN 3114-003; ASTM E2371

ASTM F67Name not checked yet
As written on the certificate · Line 5 (COFRAC 1-1648)

ISO 5832-1; ISO 6892-1; ASTM E8/E8M; ASTM F138; ASTM F139; ISO 5832-2; ASTM F67; ISO 5832-3; ASTM F136; ISO 5832-4; ISO 5832-5; ISO 5832-6; ASTM F562; ISO 5832-7; NF S 94-057; ASTM F1058; ISO 5832-8; ISO 5832-9; ASTM F1586; ISO 5832-10; ISO 5832-11; ASTM F1295; ISO 5832-12; ASTM F1537; ASTM F799; ASTM F90

As written on the certificate · Line 9 (COFRAC 1-1648)

ISO 643; ASTM E112; ASTM E407; ASTM F67; ISO 5832-2

ASTM F90Name not checked yet
As written on the certificate · Line 5 (COFRAC 1-1648)

ISO 5832-1; ISO 6892-1; ASTM E8/E8M; ASTM F138; ASTM F139; ISO 5832-2; ASTM F67; ISO 5832-3; ASTM F136; ISO 5832-4; ISO 5832-5; ISO 5832-6; ASTM F562; ISO 5832-7; NF S 94-057; ASTM F1058; ISO 5832-8; ISO 5832-9; ASTM F1586; ISO 5832-10; ISO 5832-11; ASTM F1295; ISO 5832-12; ASTM F1537; ASTM F799; ASTM F90

As written on the certificate · Line 11 (COFRAC 1-1648)

ISO 5832-6; ISO 643; ASTM E112; ASTM F562; ISO 5832-8 (1997) *; ISO 5832-12; ASTM F1537; ASTM F799; ASTM F90; ASTM E45 A; ASTM F1058; ISO 5832-7; ISO 4967; NF S 94-057 (1997) *; ISO 5832-5; ISO 5832-4; NF A 05-150; ASTM E407

ASTM F136Standard Specification for Wrought Titanium-6Aluminum-4Vanadium ELI (Extra Low Interstitial) Alloy for Surgical Implant Applications (UNS R56401)
As written on the certificate · Line 5 (COFRAC 1-1648)

ISO 5832-1; ISO 6892-1; ASTM E8/E8M; ASTM F138; ASTM F139; ISO 5832-2; ASTM F67; ISO 5832-3; ASTM F136; ISO 5832-4; ISO 5832-5; ISO 5832-6; ASTM F562; ISO 5832-7; NF S 94-057; ASTM F1058; ISO 5832-8; ISO 5832-9; ASTM F1586; ISO 5832-10; ISO 5832-11; ASTM F1295; ISO 5832-12; ASTM F1537; ASTM F799; ASTM F90

As written on the certificate · Line 10 (COFRAC 1-1648)

ISO 5832-3; NF A 05-150; ASTM E407; ISO 20160; EN 3114-003; ETTC2; ETTC4; ISO 5832-10; ISO 5832-11; ASTM F136; ASTM F1295; NF S 94-080-1; NF S 94-080-2; EN 3114-003; ETTC4; NF S 94-080-3; NF S 94-080-3; NF S 94-080-4; ISO 20160; EN 3114-002; EN 3114-003; ETTC2/ ETTC4; NF S 94-081-1; ISO 20160; EN 3114-002; ETTC2; NF S 94-081-2; ISO 20160; EN 3114-002; ETTC2

ASTM F138Standard Specification for Wrought 18Chromium-14Nickel-2.5Molybdenum Stainless Steel Bar and Wire for Surgical Implants (UNS S31673)
As written on the certificate · Line 5 (COFRAC 1-1648)

ISO 5832-1; ISO 6892-1; ASTM E8/E8M; ASTM F138; ASTM F139; ISO 5832-2; ASTM F67; ISO 5832-3; ASTM F136; ISO 5832-4; ISO 5832-5; ISO 5832-6; ASTM F562; ISO 5832-7; NF S 94-057; ASTM F1058; ISO 5832-8; ISO 5832-9; ASTM F1586; ISO 5832-10; ISO 5832-11; ASTM F1295; ISO 5832-12; ASTM F1537; ASTM F799; ASTM F90

ASTM F139Name not checked yet
As written on the certificate · Line 5 (COFRAC 1-1648)

ISO 5832-1; ISO 6892-1; ASTM E8/E8M; ASTM F138; ASTM F139; ISO 5832-2; ASTM F67; ISO 5832-3; ASTM F136; ISO 5832-4; ISO 5832-5; ISO 5832-6; ASTM F562; ISO 5832-7; NF S 94-057; ASTM F1058; ISO 5832-8; ISO 5832-9; ASTM F1586; ISO 5832-10; ISO 5832-11; ASTM F1295; ISO 5832-12; ASTM F1537; ASTM F799; ASTM F90

ASTM F543Name not checked yet
As written on the certificate · Line 7 (COFRAC 1-1648)

ASTM F543; MO-NOG-36-02

ASTM F562Name not checked yet
As written on the certificate · Line 5 (COFRAC 1-1648)

ISO 5832-1; ISO 6892-1; ASTM E8/E8M; ASTM F138; ASTM F139; ISO 5832-2; ASTM F67; ISO 5832-3; ASTM F136; ISO 5832-4; ISO 5832-5; ISO 5832-6; ASTM F562; ISO 5832-7; NF S 94-057; ASTM F1058; ISO 5832-8; ISO 5832-9; ASTM F1586; ISO 5832-10; ISO 5832-11; ASTM F1295; ISO 5832-12; ASTM F1537; ASTM F799; ASTM F90

As written on the certificate · Line 11 (COFRAC 1-1648)

ISO 5832-6; ISO 643; ASTM E112; ASTM F562; ISO 5832-8 (1997) *; ISO 5832-12; ASTM F1537; ASTM F799; ASTM F90; ASTM E45 A; ASTM F1058; ISO 5832-7; ISO 4967; NF S 94-057 (1997) *; ISO 5832-5; ISO 5832-4; NF A 05-150; ASTM E407

ASTM F799Name not checked yet
As written on the certificate · Line 5 (COFRAC 1-1648)

ISO 5832-1; ISO 6892-1; ASTM E8/E8M; ASTM F138; ASTM F139; ISO 5832-2; ASTM F67; ISO 5832-3; ASTM F136; ISO 5832-4; ISO 5832-5; ISO 5832-6; ASTM F562; ISO 5832-7; NF S 94-057; ASTM F1058; ISO 5832-8; ISO 5832-9; ASTM F1586; ISO 5832-10; ISO 5832-11; ASTM F1295; ISO 5832-12; ASTM F1537; ASTM F799; ASTM F90

As written on the certificate · Line 11 (COFRAC 1-1648)

ISO 5832-6; ISO 643; ASTM E112; ASTM F562; ISO 5832-8 (1997) *; ISO 5832-12; ASTM F1537; ASTM F799; ASTM F90; ASTM E45 A; ASTM F1058; ISO 5832-7; ISO 4967; NF S 94-057 (1997) *; ISO 5832-5; ISO 5832-4; NF A 05-150; ASTM E407

ASTM F1058Name not checked yet
As written on the certificate · Line 5 (COFRAC 1-1648)

ISO 5832-1; ISO 6892-1; ASTM E8/E8M; ASTM F138; ASTM F139; ISO 5832-2; ASTM F67; ISO 5832-3; ASTM F136; ISO 5832-4; ISO 5832-5; ISO 5832-6; ASTM F562; ISO 5832-7; NF S 94-057; ASTM F1058; ISO 5832-8; ISO 5832-9; ASTM F1586; ISO 5832-10; ISO 5832-11; ASTM F1295; ISO 5832-12; ASTM F1537; ASTM F799; ASTM F90

As written on the certificate · Line 11 (COFRAC 1-1648)

ISO 5832-6; ISO 643; ASTM E112; ASTM F562; ISO 5832-8 (1997) *; ISO 5832-12; ASTM F1537; ASTM F799; ASTM F90; ASTM E45 A; ASTM F1058; ISO 5832-7; ISO 4967; NF S 94-057 (1997) *; ISO 5832-5; ISO 5832-4; NF A 05-150; ASTM E407

ASTM F1089Name not checked yet
As written on the certificate · Line 12 (COFRAC 1-1648)

ASTM A967 / A967M; ASTM A967-17; ASTM F1089; ASTM F1089-18; ASTM F1854

ASTM F1295Name not checked yet
As written on the certificate · Line 5 (COFRAC 1-1648)

ISO 5832-1; ISO 6892-1; ASTM E8/E8M; ASTM F138; ASTM F139; ISO 5832-2; ASTM F67; ISO 5832-3; ASTM F136; ISO 5832-4; ISO 5832-5; ISO 5832-6; ASTM F562; ISO 5832-7; NF S 94-057; ASTM F1058; ISO 5832-8; ISO 5832-9; ASTM F1586; ISO 5832-10; ISO 5832-11; ASTM F1295; ISO 5832-12; ASTM F1537; ASTM F799; ASTM F90

As written on the certificate · Line 10 (COFRAC 1-1648)

ISO 5832-3; NF A 05-150; ASTM E407; ISO 20160; EN 3114-003; ETTC2; ETTC4; ISO 5832-10; ISO 5832-11; ASTM F136; ASTM F1295; NF S 94-080-1; NF S 94-080-2; EN 3114-003; ETTC4; NF S 94-080-3; NF S 94-080-3; NF S 94-080-4; ISO 20160; EN 3114-002; EN 3114-003; ETTC2/ ETTC4; NF S 94-081-1; ISO 20160; EN 3114-002; ETTC2; NF S 94-081-2; ISO 20160; EN 3114-002; ETTC2

ASTM F1537Name not checked yet
As written on the certificate · Line 5 (COFRAC 1-1648)

ISO 5832-1; ISO 6892-1; ASTM E8/E8M; ASTM F138; ASTM F139; ISO 5832-2; ASTM F67; ISO 5832-3; ASTM F136; ISO 5832-4; ISO 5832-5; ISO 5832-6; ASTM F562; ISO 5832-7; NF S 94-057; ASTM F1058; ISO 5832-8; ISO 5832-9; ASTM F1586; ISO 5832-10; ISO 5832-11; ASTM F1295; ISO 5832-12; ASTM F1537; ASTM F799; ASTM F90

As written on the certificate · Line 11 (COFRAC 1-1648)

ISO 5832-6; ISO 643; ASTM E112; ASTM F562; ISO 5832-8 (1997) *; ISO 5832-12; ASTM F1537; ASTM F799; ASTM F90; ASTM E45 A; ASTM F1058; ISO 5832-7; ISO 4967; NF S 94-057 (1997) *; ISO 5832-5; ISO 5832-4; NF A 05-150; ASTM E407

ASTM F1586Name not checked yet
As written on the certificate · Line 5 (COFRAC 1-1648)

ISO 5832-1; ISO 6892-1; ASTM E8/E8M; ASTM F138; ASTM F139; ISO 5832-2; ASTM F67; ISO 5832-3; ASTM F136; ISO 5832-4; ISO 5832-5; ISO 5832-6; ASTM F562; ISO 5832-7; NF S 94-057; ASTM F1058; ISO 5832-8; ISO 5832-9; ASTM F1586; ISO 5832-10; ISO 5832-11; ASTM F1295; ISO 5832-12; ASTM F1537; ASTM F799; ASTM F90

ASTM F1854Name not checked yet
As written on the certificate · Line 12 (COFRAC 1-1648)

ASTM A967 / A967M; ASTM A967-17; ASTM F1089; ASTM F1089-18; ASTM F1854

ISO 5832 series

ISO 5832-1Implants for surgery - Metallic materials - Part 1: Wrought stainless steel
As written on the certificate · Line 5 (COFRAC 1-1648)

ISO 5832-1; ISO 6892-1; ASTM E8/E8M; ASTM F138; ASTM F139; ISO 5832-2; ASTM F67; ISO 5832-3; ASTM F136; ISO 5832-4; ISO 5832-5; ISO 5832-6; ASTM F562; ISO 5832-7; NF S 94-057; ASTM F1058; ISO 5832-8; ISO 5832-9; ASTM F1586; ISO 5832-10; ISO 5832-11; ASTM F1295; ISO 5832-12; ASTM F1537; ASTM F799; ASTM F90

ISO 5832-2Implants for surgery - Metallic materials - Part 2: Unalloyed titanium
As written on the certificate · Line 5 (COFRAC 1-1648)

ISO 5832-1; ISO 6892-1; ASTM E8/E8M; ASTM F138; ASTM F139; ISO 5832-2; ASTM F67; ISO 5832-3; ASTM F136; ISO 5832-4; ISO 5832-5; ISO 5832-6; ASTM F562; ISO 5832-7; NF S 94-057; ASTM F1058; ISO 5832-8; ISO 5832-9; ASTM F1586; ISO 5832-10; ISO 5832-11; ASTM F1295; ISO 5832-12; ASTM F1537; ASTM F799; ASTM F90

As written on the certificate · Line 9 (COFRAC 1-1648)

ISO 643; ASTM E112; ASTM E407; ASTM F67; ISO 5832-2

ISO 5832-3Implants for surgery - Metallic materials - Part 3: Wrought titanium 6-aluminium 4-vanadium alloy
As written on the certificate · Line 5 (COFRAC 1-1648)

ISO 5832-1; ISO 6892-1; ASTM E8/E8M; ASTM F138; ASTM F139; ISO 5832-2; ASTM F67; ISO 5832-3; ASTM F136; ISO 5832-4; ISO 5832-5; ISO 5832-6; ASTM F562; ISO 5832-7; NF S 94-057; ASTM F1058; ISO 5832-8; ISO 5832-9; ASTM F1586; ISO 5832-10; ISO 5832-11; ASTM F1295; ISO 5832-12; ASTM F1537; ASTM F799; ASTM F90

As written on the certificate · Line 10 (COFRAC 1-1648)

ISO 5832-3; NF A 05-150; ASTM E407; ISO 20160; EN 3114-003; ETTC2; ETTC4; ISO 5832-10; ISO 5832-11; ASTM F136; ASTM F1295; NF S 94-080-1; NF S 94-080-2; EN 3114-003; ETTC4; NF S 94-080-3; NF S 94-080-3; NF S 94-080-4; ISO 20160; EN 3114-002; EN 3114-003; ETTC2/ ETTC4; NF S 94-081-1; ISO 20160; EN 3114-002; ETTC2; NF S 94-081-2; ISO 20160; EN 3114-002; ETTC2

ISO 5832-4Implants for surgery - Metallic materials - Part 4: Cobalt-chromium-molybdenum casting alloy
As written on the certificate · Line 5 (COFRAC 1-1648)

ISO 5832-1; ISO 6892-1; ASTM E8/E8M; ASTM F138; ASTM F139; ISO 5832-2; ASTM F67; ISO 5832-3; ASTM F136; ISO 5832-4; ISO 5832-5; ISO 5832-6; ASTM F562; ISO 5832-7; NF S 94-057; ASTM F1058; ISO 5832-8; ISO 5832-9; ASTM F1586; ISO 5832-10; ISO 5832-11; ASTM F1295; ISO 5832-12; ASTM F1537; ASTM F799; ASTM F90

As written on the certificate · Line 11 (COFRAC 1-1648)

ISO 5832-6; ISO 643; ASTM E112; ASTM F562; ISO 5832-8 (1997) *; ISO 5832-12; ASTM F1537; ASTM F799; ASTM F90; ASTM E45 A; ASTM F1058; ISO 5832-7; ISO 4967; NF S 94-057 (1997) *; ISO 5832-5; ISO 5832-4; NF A 05-150; ASTM E407

ISO 5832-5Implants for surgery - Metallic materials - Part 5: Wrought cobalt-chromium-tungsten-nickel
As written on the certificate · Line 5 (COFRAC 1-1648)

ISO 5832-1; ISO 6892-1; ASTM E8/E8M; ASTM F138; ASTM F139; ISO 5832-2; ASTM F67; ISO 5832-3; ASTM F136; ISO 5832-4; ISO 5832-5; ISO 5832-6; ASTM F562; ISO 5832-7; NF S 94-057; ASTM F1058; ISO 5832-8; ISO 5832-9; ASTM F1586; ISO 5832-10; ISO 5832-11; ASTM F1295; ISO 5832-12; ASTM F1537; ASTM F799; ASTM F90

As written on the certificate · Line 11 (COFRAC 1-1648)

ISO 5832-6; ISO 643; ASTM E112; ASTM F562; ISO 5832-8 (1997) *; ISO 5832-12; ASTM F1537; ASTM F799; ASTM F90; ASTM E45 A; ASTM F1058; ISO 5832-7; ISO 4967; NF S 94-057 (1997) *; ISO 5832-5; ISO 5832-4; NF A 05-150; ASTM E407

ISO 5832-6Implants for surgery - Metallic materials - Part 6: Wrought cobalt-nickel-chromium-molybdenum alloy
As written on the certificate · Line 5 (COFRAC 1-1648)

ISO 5832-1; ISO 6892-1; ASTM E8/E8M; ASTM F138; ASTM F139; ISO 5832-2; ASTM F67; ISO 5832-3; ASTM F136; ISO 5832-4; ISO 5832-5; ISO 5832-6; ASTM F562; ISO 5832-7; NF S 94-057; ASTM F1058; ISO 5832-8; ISO 5832-9; ASTM F1586; ISO 5832-10; ISO 5832-11; ASTM F1295; ISO 5832-12; ASTM F1537; ASTM F799; ASTM F90

As written on the certificate · Line 11 (COFRAC 1-1648)

ISO 5832-6; ISO 643; ASTM E112; ASTM F562; ISO 5832-8 (1997) *; ISO 5832-12; ASTM F1537; ASTM F799; ASTM F90; ASTM E45 A; ASTM F1058; ISO 5832-7; ISO 4967; NF S 94-057 (1997) *; ISO 5832-5; ISO 5832-4; NF A 05-150; ASTM E407

ISO 5832-7Implants for surgery - Metallic materials - Part 7: Forgeable and cold-formed cobalt-chromium-nickel-molybdenum-iron alloy
As written on the certificate · Line 5 (COFRAC 1-1648)

ISO 5832-1; ISO 6892-1; ASTM E8/E8M; ASTM F138; ASTM F139; ISO 5832-2; ASTM F67; ISO 5832-3; ASTM F136; ISO 5832-4; ISO 5832-5; ISO 5832-6; ASTM F562; ISO 5832-7; NF S 94-057; ASTM F1058; ISO 5832-8; ISO 5832-9; ASTM F1586; ISO 5832-10; ISO 5832-11; ASTM F1295; ISO 5832-12; ASTM F1537; ASTM F799; ASTM F90

As written on the certificate · Line 11 (COFRAC 1-1648)

ISO 5832-6; ISO 643; ASTM E112; ASTM F562; ISO 5832-8 (1997) *; ISO 5832-12; ASTM F1537; ASTM F799; ASTM F90; ASTM E45 A; ASTM F1058; ISO 5832-7; ISO 4967; NF S 94-057 (1997) *; ISO 5832-5; ISO 5832-4; NF A 05-150; ASTM E407

ISO 5832-8Implants for surgery - Metallic materials - Part 8: Wrought cobalt-nickel-chromium-molybdenum- tungsten-iron alloy
As written on the certificate · Line 5 (COFRAC 1-1648)

ISO 5832-1; ISO 6892-1; ASTM E8/E8M; ASTM F138; ASTM F139; ISO 5832-2; ASTM F67; ISO 5832-3; ASTM F136; ISO 5832-4; ISO 5832-5; ISO 5832-6; ASTM F562; ISO 5832-7; NF S 94-057; ASTM F1058; ISO 5832-8; ISO 5832-9; ASTM F1586; ISO 5832-10; ISO 5832-11; ASTM F1295; ISO 5832-12; ASTM F1537; ASTM F799; ASTM F90

As written on the certificate · Line 11 (COFRAC 1-1648)

ISO 5832-6; ISO 643; ASTM E112; ASTM F562; ISO 5832-8 (1997) *; ISO 5832-12; ASTM F1537; ASTM F799; ASTM F90; ASTM E45 A; ASTM F1058; ISO 5832-7; ISO 4967; NF S 94-057 (1997) *; ISO 5832-5; ISO 5832-4; NF A 05-150; ASTM E407

ISO 5832-9Implants for surgery - Metallic materials - Part 9: Wrought high nitrogen stainless steel
As written on the certificate · Line 5 (COFRAC 1-1648)

ISO 5832-1; ISO 6892-1; ASTM E8/E8M; ASTM F138; ASTM F139; ISO 5832-2; ASTM F67; ISO 5832-3; ASTM F136; ISO 5832-4; ISO 5832-5; ISO 5832-6; ASTM F562; ISO 5832-7; NF S 94-057; ASTM F1058; ISO 5832-8; ISO 5832-9; ASTM F1586; ISO 5832-10; ISO 5832-11; ASTM F1295; ISO 5832-12; ASTM F1537; ASTM F799; ASTM F90

ISO 5832-10Implants for surgery - Metallic materials - Part 10: Wrought titanium 5-aluminium 2,5-iron alloy
As written on the certificate · Line 5 (COFRAC 1-1648)

ISO 5832-1; ISO 6892-1; ASTM E8/E8M; ASTM F138; ASTM F139; ISO 5832-2; ASTM F67; ISO 5832-3; ASTM F136; ISO 5832-4; ISO 5832-5; ISO 5832-6; ASTM F562; ISO 5832-7; NF S 94-057; ASTM F1058; ISO 5832-8; ISO 5832-9; ASTM F1586; ISO 5832-10; ISO 5832-11; ASTM F1295; ISO 5832-12; ASTM F1537; ASTM F799; ASTM F90

As written on the certificate · Line 10 (COFRAC 1-1648)

ISO 5832-3; NF A 05-150; ASTM E407; ISO 20160; EN 3114-003; ETTC2; ETTC4; ISO 5832-10; ISO 5832-11; ASTM F136; ASTM F1295; NF S 94-080-1; NF S 94-080-2; EN 3114-003; ETTC4; NF S 94-080-3; NF S 94-080-3; NF S 94-080-4; ISO 20160; EN 3114-002; EN 3114-003; ETTC2/ ETTC4; NF S 94-081-1; ISO 20160; EN 3114-002; ETTC2; NF S 94-081-2; ISO 20160; EN 3114-002; ETTC2

ISO 5832-11Implants for surgery - Metallic materials - Part 11: Wrought titanium 6-aluminium 7-niobium alloy
As written on the certificate · Line 5 (COFRAC 1-1648)

ISO 5832-1; ISO 6892-1; ASTM E8/E8M; ASTM F138; ASTM F139; ISO 5832-2; ASTM F67; ISO 5832-3; ASTM F136; ISO 5832-4; ISO 5832-5; ISO 5832-6; ASTM F562; ISO 5832-7; NF S 94-057; ASTM F1058; ISO 5832-8; ISO 5832-9; ASTM F1586; ISO 5832-10; ISO 5832-11; ASTM F1295; ISO 5832-12; ASTM F1537; ASTM F799; ASTM F90

As written on the certificate · Line 10 (COFRAC 1-1648)

ISO 5832-3; NF A 05-150; ASTM E407; ISO 20160; EN 3114-003; ETTC2; ETTC4; ISO 5832-10; ISO 5832-11; ASTM F136; ASTM F1295; NF S 94-080-1; NF S 94-080-2; EN 3114-003; ETTC4; NF S 94-080-3; NF S 94-080-3; NF S 94-080-4; ISO 20160; EN 3114-002; EN 3114-003; ETTC2/ ETTC4; NF S 94-081-1; ISO 20160; EN 3114-002; ETTC2; NF S 94-081-2; ISO 20160; EN 3114-002; ETTC2

ISO 5832-12Implants for surgery - Metallic materials - Part 12: Wrought cobalt-chromium-molybdenum alloy
As written on the certificate · Line 5 (COFRAC 1-1648)

ISO 5832-1; ISO 6892-1; ASTM E8/E8M; ASTM F138; ASTM F139; ISO 5832-2; ASTM F67; ISO 5832-3; ASTM F136; ISO 5832-4; ISO 5832-5; ISO 5832-6; ASTM F562; ISO 5832-7; NF S 94-057; ASTM F1058; ISO 5832-8; ISO 5832-9; ASTM F1586; ISO 5832-10; ISO 5832-11; ASTM F1295; ISO 5832-12; ASTM F1537; ASTM F799; ASTM F90

As written on the certificate · Line 11 (COFRAC 1-1648)

ISO 5832-6; ISO 643; ASTM E112; ASTM F562; ISO 5832-8 (1997) *; ISO 5832-12; ASTM F1537; ASTM F799; ASTM F90; ASTM E45 A; ASTM F1058; ISO 5832-7; ISO 4967; NF S 94-057 (1997) *; ISO 5832-5; ISO 5832-4; NF A 05-150; ASTM E407

ISO

ISO 643Steels - Micrographic determination of the apparent grain size
As written on the certificate · Line 2 (COFRAC 1-1648)

NF EN ISO 6892-1; ASTM E8/8M; ASTM E407; NF A 05-150; DMC 0090; NF EN ISO 643; NF A 04-503; NF A 04-505; NF EN ISO 2624; ASTM E112; ISO 4967; ASTM E45; SAE AMS 2315; NF EN 2003-009; PR 6110

As written on the certificate · Line 8 (COFRAC 1-1648)

ISO 643; ISO 4967; NF A 05-150; ASTM E407; ASTM E112; ASTM E45 A

As written on the certificate · Line 9 (COFRAC 1-1648)

ISO 643; ASTM E112; ASTM E407; ASTM F67; ISO 5832-2

As written on the certificate · Line 11 (COFRAC 1-1648)

ISO 5832-6; ISO 643; ASTM E112; ASTM F562; ISO 5832-8 (1997) *; ISO 5832-12; ASTM F1537; ASTM F799; ASTM F90; ASTM E45 A; ASTM F1058; ISO 5832-7; ISO 4967; NF S 94-057 (1997) *; ISO 5832-5; ISO 5832-4; NF A 05-150; ASTM E407

ISO 2624Copper and copper alloys - Estimation of average grain size
As written on the certificate · Line 2 (COFRAC 1-1648)

NF EN ISO 6892-1; ASTM E8/8M; ASTM E407; NF A 05-150; DMC 0090; NF EN ISO 643; NF A 04-503; NF A 04-505; NF EN ISO 2624; ASTM E112; ISO 4967; ASTM E45; SAE AMS 2315; NF EN 2003-009; PR 6110

ISO 4967Steel - Determination of the non-metallic inclusion content - Micrographic method
As written on the certificate · Line 2 (COFRAC 1-1648)

NF EN ISO 6892-1; ASTM E8/8M; ASTM E407; NF A 05-150; DMC 0090; NF EN ISO 643; NF A 04-503; NF A 04-505; NF EN ISO 2624; ASTM E112; ISO 4967; ASTM E45; SAE AMS 2315; NF EN 2003-009; PR 6110

As written on the certificate · Line 8 (COFRAC 1-1648)

ISO 643; ISO 4967; NF A 05-150; ASTM E407; ASTM E112; ASTM E45 A

As written on the certificate · Line 11 (COFRAC 1-1648)

ISO 5832-6; ISO 643; ASTM E112; ASTM F562; ISO 5832-8 (1997) *; ISO 5832-12; ASTM F1537; ASTM F799; ASTM F90; ASTM E45 A; ASTM F1058; ISO 5832-7; ISO 4967; NF S 94-057 (1997) *; ISO 5832-5; ISO 5832-4; NF A 05-150; ASTM E407

ISO 6892-1Metallic materials - Tensile testing - Part 1: Method of test at room temperature
As written on the certificate · Line 2 (COFRAC 1-1648)

NF EN ISO 6892-1; ASTM E8/8M; ASTM E407; NF A 05-150; DMC 0090; NF EN ISO 643; NF A 04-503; NF A 04-505; NF EN ISO 2624; ASTM E112; ISO 4967; ASTM E45; SAE AMS 2315; NF EN 2003-009; PR 6110

As written on the certificate · Line 5 (COFRAC 1-1648)

ISO 5832-1; ISO 6892-1; ASTM E8/E8M; ASTM F138; ASTM F139; ISO 5832-2; ASTM F67; ISO 5832-3; ASTM F136; ISO 5832-4; ISO 5832-5; ISO 5832-6; ASTM F562; ISO 5832-7; NF S 94-057; ASTM F1058; ISO 5832-8; ISO 5832-9; ASTM F1586; ISO 5832-10; ISO 5832-11; ASTM F1295; ISO 5832-12; ASTM F1537; ASTM F799; ASTM F90

As written on the certificate · Line 6 (COFRAC 1-1648)

ISO 6892-1

ISO 9377-2Water quality - Determination of hydrocarbon oil index - Part 2: Method using solvent extraction and gas chromatography
As written on the certificate · Line 4 (COFRAC 1-1648)

NF ISO 13779-3; NF EN ISO 9377-2; ISO 19227; MO-NOG-26; NF EN 1484; ISO 10304-1

ISO 10304-1Water quality - Determination of dissolved anions by liquid chromatography of ions - Part 1: Determination of bromide, chloride, fluoride, nitrate, nitrite, phosphate and sulfate
As written on the certificate · Line 4 (COFRAC 1-1648)

NF ISO 13779-3; NF EN ISO 9377-2; ISO 19227; MO-NOG-26; NF EN 1484; ISO 10304-1

ISO 13779-3Implants for surgery - Hydroxyapatite - Part 3: Chemical analysis and characterization of crystallinity ratio and phase purity
As written on the certificate · Line 4 (COFRAC 1-1648)

NF ISO 13779-3; NF EN ISO 9377-2; ISO 19227; MO-NOG-26; NF EN 1484; ISO 10304-1

ISO 19227Implants for surgery - Cleanliness of orthopedic implants - General requirements
As written on the certificate · Line 4 (COFRAC 1-1648)

NF ISO 13779-3; NF EN ISO 9377-2; ISO 19227; MO-NOG-26; NF EN 1484; ISO 10304-1

ISO 20160Implants for surgery - Metallic materials - Classification of microstructures for alpha+beta titanium alloy bars
As written on the certificate · Line 10 (COFRAC 1-1648)

ISO 5832-3; NF A 05-150; ASTM E407; ISO 20160; EN 3114-003; ETTC2; ETTC4; ISO 5832-10; ISO 5832-11; ASTM F136; ASTM F1295; NF S 94-080-1; NF S 94-080-2; EN 3114-003; ETTC4; NF S 94-080-3; NF S 94-080-3; NF S 94-080-4; ISO 20160; EN 3114-002; EN 3114-003; ETTC2/ ETTC4; NF S 94-081-1; ISO 20160; EN 3114-002; ETTC2; NF S 94-081-2; ISO 20160; EN 3114-002; ETTC2

EN 3114 series

EN 3114-001Name not checked yet
As written on the certificate · Line 3 (COFRAC 1-1648)

NF EN 3114-001; NF EN 3114-002; NF EN 3114-003; ASTM E2371

EN 3114-002Name not checked yet
As written on the certificate · Line 3 (COFRAC 1-1648)

NF EN 3114-001; NF EN 3114-002; NF EN 3114-003; ASTM E2371

As written on the certificate · Line 10 (COFRAC 1-1648)

ISO 5832-3; NF A 05-150; ASTM E407; ISO 20160; EN 3114-003; ETTC2; ETTC4; ISO 5832-10; ISO 5832-11; ASTM F136; ASTM F1295; NF S 94-080-1; NF S 94-080-2; EN 3114-003; ETTC4; NF S 94-080-3; NF S 94-080-3; NF S 94-080-4; ISO 20160; EN 3114-002; EN 3114-003; ETTC2/ ETTC4; NF S 94-081-1; ISO 20160; EN 3114-002; ETTC2; NF S 94-081-2; ISO 20160; EN 3114-002; ETTC2

EN 3114-003Name not checked yet
As written on the certificate · Line 3 (COFRAC 1-1648)

NF EN 3114-001; NF EN 3114-002; NF EN 3114-003; ASTM E2371

As written on the certificate · Line 10 (COFRAC 1-1648)

ISO 5832-3; NF A 05-150; ASTM E407; ISO 20160; EN 3114-003; ETTC2; ETTC4; ISO 5832-10; ISO 5832-11; ASTM F136; ASTM F1295; NF S 94-080-1; NF S 94-080-2; EN 3114-003; ETTC4; NF S 94-080-3; NF S 94-080-3; NF S 94-080-4; ISO 20160; EN 3114-002; EN 3114-003; ETTC2/ ETTC4; NF S 94-081-1; ISO 20160; EN 3114-002; ETTC2; NF S 94-081-2; ISO 20160; EN 3114-002; ETTC2

Other standards

EN 1484Water analysis - Guidelines for the determination of total organic carbon (TOC) and dissolved organic carbon (DOC)
As written on the certificate · Line 4 (COFRAC 1-1648)

NF ISO 13779-3; NF EN ISO 9377-2; ISO 19227; MO-NOG-26; NF EN 1484; ISO 10304-1

EN 2003-009Name not checked yet
As written on the certificate · Line 2 (COFRAC 1-1648)

NF EN ISO 6892-1; ASTM E8/8M; ASTM E407; NF A 05-150; DMC 0090; NF EN ISO 643; NF A 04-503; NF A 04-505; NF EN ISO 2624; ASTM E112; ISO 4967; ASTM E45; SAE AMS 2315; NF EN 2003-009; PR 6110

Scope as published by COFRAC

13 lines
COFRAC

ISO/IEC 17025

Active

1-1648

View scope

Location

RUE LAVOISIER POLE TECHNOLOGIQUE DE HAUTE CHAMPAGNE, NOGENT, 52800, FR

48.02698, 5.34169

Open in Maps

Accreditation data refreshed from the COFRAC register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the COFRAC entry linked above.