ICL Calibration Laboratories, Inc.
1501 SE Decker Avenue, Suite 118, 34994, Stuart, FL, United States
- Accredited standards
- 4
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 4 standard numbers and the 1 official names we hold. When no standard matches, it searches the method text of every scope line.
ASTM E100
ASTM E126
ASTM E617Standard Specification for Laboratory Weights and Precision Mass Standards
ASTM E2995
ASTM E126; ASTM E100; ASTM E2995
ASTM E617; NISTIR 6969
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-10-23.
Scope as published by A2LA
5 lines
ISO/IEC 17025
Active526.01
The scope document we hold says it is valid until 2026-11-30.
Accredited scope, certificate 526.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ASTM E126; ASTM E100; ASTM E2995 | - | See scope document |
| 2 | ASTM E617; NISTIR 6969 | laboratory weights | See scope document |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 0526.01) 12/04/2024 Page 3 of 4
III. Thermodynamics
Parameter/Equipment
Range
CMC2 (±)
Comments
Temperature – Digital Thermometers,
PRTs, RTDs, Thermistors,
Thermocouples, Liquid-in-Glass
Thermometers, Temperature Recorders
and Loggers
Fluke 1595A Super Thermometers,
Rosemount 162CE SPRTs, Fluke
5628-15 Secondary Reference PRTs
Fluke Liquid Baths, Metrology Wells
and Furnaces
Fluke Black Stack and 5650 Type S
Thermocouple
Approx. -196 °C
(-80 to < -40) °C
(-40 to < 0) °C
0 °C
0.01 °C
(>0 to 100) °C
(>100 to 200) °C
(>200 to 300) °C
(>300 to 420) °C
(>420 to 660) °C
(>600 to 961) °C
(>961 to 1000) °C
0.0072 °C (7.2 mK)
0.0082 °C (8.2 mK)
0.0078 °C (7.8 mK)
0.0037 °C (3.7 mK)
0.0021 °C (2.1 mK)
0.010 °C (10 mK)
0.011 °C (11 mK)
0.014 °C (14 mK)
0.018 °C (18 mK)
0.051 °C (51 mK)
1.3 °C (1.3 K)
3.5 °C (3.5 K)
Comparison in
stabilization
block in liquid
nitrogen bath with
SPRT or
secondary
reference PRT
Comparison in
liquid baths with
SPRT or
secondary
reference PRT
Ice point
Triple point of
water cells
Comparison in
liquid baths with
SPRT or
secondary
reference PRT
Comparison in
Fluke 9173
metrology well
with secondary
reference PRT
Comparison with
Type S
thermocouple in
Fluke 9150
furnace
__________________________________________
1 This laboratory offers commercial calibration service. | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 0526.01) 12/04/2024 Page 4 of 4
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 5 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.