Registers refreshed 2026-11-20.See refresh dates
United Kingdom

Kingston University Enterprise Limited trading as Kingston Analytical Services Toxicology (KAST)

Hind Court, 106 - 114 London Road, KT2 6TN, Kingston, United Kingdom

Visit website
UKAS 23543ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
2
UKAS certificate
1
Site in our directory
1
UKAS accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 2 scope lines.

UKAS certificate 23543 · 2 lines

LineMethodMatrixRange
1-Blood
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

Assessment Manager: VR Page 1 of 2 Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 23543 Accredited to ISO/IEC 17025:2017 Kingston University Enterprise Limited trading as Kingston Analytical Services Toxicology (KAST) Issue No: 006 Issue date: 10 November 2025 Hind Court 106 - 114 London Road Kingston KT2 6TN GBR Contact: Dr B Rooney Tel: +44 (0)208 417 2048 E-Mail: KAST@kingston.ac.uk Website: www.kastforensics.com/ Testing performed at the above address only DETAIL OF ACCREDITATION Materials/Products tested Type of test/Properties measured/Range of measurement Standard specifications/ Equipment/Techniques used The organisation has demonstrated compliance to the Forensic Science Regulator Code of Practice V2 in relation to the Forensic Activities listed below. BODY FLUIDS Whole Blood (Preserved) Detection and quantitation of drugs in relation to s5A of the Road Traffic Act 1988 (as amended) and The Drug Driving (Specified Limits) (England and Wales) Regulations 2014 (Cut-off) [Concentration Range]: Documented in house methods: - Benzoylecgonine (50 µg/L) [25- 500ng/mL] - Cocaine (10 µg/L) [5-100ng/mL] KSTPr 013 by GCMS-MS - Delta-9-tetrahydrocannabinol (2 µg/L) [1-20ng/mL] KSTPr 014 by GCMS-MS - Morphine (80 μg/L); [40-140 μg/L] - 6-AM (5 μg/L); [2.5-15 μg/L] - Methadone (500 μg/L); [250-875 μg/L] KSTPr 053 by GCMS-MS
See scope document
2ISO/IEC 17025:2017BloodSee scope document

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Hind Court, 106 - 114 London Road, Kingston, KT2 6TN, GB

51.41037, -0.29364

Open in Maps

Accreditation data refreshed from the UKAS register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the UKAS entry linked above.