ACOME
Usine de Mortain/Romagny BP 45, 50140, MORTAIN, France
- Accredited standards
- 10
- COFRAC certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the COFRAC scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 10 standard numbers and the 1 official name we hold. When no standard matches, it searches the method text of every scope line.
EN 50399
IEC 60332-1-1
IEC 60332-1-2Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame
IEC 60332-1-3
IEC 60332-3-10
IEC 60332-3-21
IEC 60754-2
IEC 60754-3
IEC 61034-1
IEC 61034-2
EN 50399; EN 61034-1; EN 61034-2; CEI 61034-1; CEI 61034-2
NF C 32070 essai 1; C 32078-1; EN 60332-1-1; EN 60332-1-2; EN 60332-1-3; CEI 60332-1-1; CEI 60332-1-2; CEI 60332-1-3; C 32078-3; CEI 60332-3-10; CEI 60332-3-21 à 25; EN 60332-3-10; EN 60332-3-21 à 25
NF C 20453; C 32074; EN 60754-2; CEI 60754-2; NF C 20454; NF X 70100-1; NF X 70100-2; EN 60754-03
Read from the COFRAC scope document we downloaded on 2026-02-12. Register refreshed 2026-11-20.
Scope as published by COFRAC
4 lines
ISO/IEC 17025
Active1-1114
The scope document we hold says it is valid until 2030-02-28.
Accredited scope, certificate 1-1114
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | NF EN ISO/IEC 17025 | ALL ELECTRICAL AND/OR ELECTRONICAL EQUIPMENT OR PRODUCT SUBJECT TO FIRE BEHAVIOUR TESTING | - |
| 2 | NF C 32070 essai 1; C 32078-1; EN 60332-1-1; EN 60332-1-2; EN 60332-1-3; CEI 60332-1-1; CEI 60332-1-2; CEI 60332-1-3; C 32078-3; CEI 60332-3-10; CEI 60332-3-21 à 25; EN 60332-3-10; EN 60332-3-21 à 25 | Conducteurs, câbles électriques ou à fibres optiques; Conducteurs, câbles électriques ou à fibres optiques (en nappe) | 0 to 60 cm |
| 3 | EN 50399; EN 61034-1; EN 61034-2; CEI 61034-1; CEI 61034-2 | Conducteurs, câbles électriques ou à fibres optiques | 0 to 500 kW |
| 4 | NF C 20453; C 32074; EN 60754-2; CEI 60754-2; NF C 20454; NF X 70100-1; NF X 70100-2; EN 60754-03 | Matériau isolant ou gaine de câble | 1 to 14 |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.