Element Materials Technology Detroit
1150 W. Maple Road, 48084, Troy, MI, United States
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at Element Materials Technology Detroit?
Claim this profile to keep it accurate.
Register record
- A2LARefreshed
- 98.10Active
- 98.09Active
Accredited standards
We found no published test standard numbers in this lab’s scope (labs often list in-house methods instead). The full scope as published is below.
Scope as published by A2LA
6 lines
ISO/IEC 17025
Active98.10
The scope document we hold says it is valid until 2027-05-31.
Accredited scope, certificate 98.10
This scope has not been split into individual lines yet. Below is the text of the scope document as published.
Part 1 of 3
(A2LA Cert. No. 0098.09) Revised 6/29/2026 Page 1 of 2 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 MGA RESEARCH CORPORATION-TROY 1150 W. Maple Rd. Troy, MI 48084 Scott Arsen Phone: 248-577-5001 Email: scott.arsen@mgaresearch.com MECHANICAL Valid To: May 31, 2027 Certificate Number: 0098.09 In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory at the location listed above to perform the following tests on: automotive components (brackets, structural members, suspension components, seats, body panels and interior parts): Test and Test Parameters1: Test Method(s)/Standard(s): Axial and Bending, Monotonic Testing2 Force: up to 100 000 lbf. Displacement: up to 12 in. In Possible Environmental Conditions of (-40 to 180) °F RBA 245 (Axle Tech) Axial and Bending, Fatigue Testing2 Force: up to 100 000 lbf. Displacement: up to 12 in. In Possible Environmental Conditions of (-40 to 180) °F SAE J684 Torsional, Monotonic and Fatigue Testing2 Up to 8 000 ft⸱lbf, 20 000 RPM, and 50 HP In Possible Environmental Conditions of (-40 to 180) °F SOP-TR-PR-001 Environmental2 Temperature: (-40 to 180) °F using Various Chambers CEPT 01-03-L-311 Static Testing2 Static Bending and Torsion Displacement: Up to 2 in. Force application: Up to 11 000 lbf. Up to 64 Channels Acquisition (+/- 10 V) GMW-3067, GMW7699 Multi-Axis Simulation Table(s) (MAST)2 Up to 50 Hz Bounce, Vertical, Pitch, Roll, Yaw, Lateral and Longitudinal Inputs DVM 0009-ST
Part 2 of 3
(A2LA Cert. No. 0098.09) Revised 6/29/2026 Page 2 of 2 Test and Test Parameters: Test Method(s)/Standard(s): Vehicle and Laboratory Data Acquisition3 SOP-TR-PR-002 Four Post (Wheel) Road Simulation2 Up to 50 Hz Up to 55 kip Actuators SOP-TR-PR-003 Spindle-Coupled Road Simulation (329 LT)2 Up to 50 Hz SOP-TR-PR-004 Spindle-Coupled Road Simulation (329 PC)2 Up to 50 Hz SOP-TR-PR-005 Temperature2 High/Low/Cyclic Temperature without Humidity2 (-65 to 165) ºC Temperature Capability with Humidity2 (-50 to 150) ºC (30% to 95%) RH Thermal Shock2 (-50 to 150) ºC Single Chamber Dynamometer2 Driveline: Performance, Fatigue, Durability Up to 600 HP, Torque Up to 8,333 ft/lbs, Speed Up to 25,000 RPM Pressure2 0 to 1000 psi Liquid Flow2 up to 10 gpm Chemical Resistance2 Per customer specification 1This scope meets A2LA’s P112 Flexible Scope Policy. 2This laboratory also uses customer supplied test methods utilizing any combination of test equipment parameters listed above. 3This laboratory performs field testing activities for these tests.
Part 3 of 3
For the tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation. Accredited Laboratory A2LA has accredited MGA RESEARCH CORPORATION-TROY Troy, MI for technical competence in the field of Mechanical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 20th day of June 2025. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 0098.09 Valid to May 31, 2027 Revised June 29, 2026
Text extracted from the accredited scope document. Layout and tables from the original may not carry over; the scope document itself is the authoritative copy.
ISO/IEC 17025
Active98.09
The scope document we hold says it is valid until 2027-05-31.
Accredited scope, certificate 98.09
This scope has not been split into individual lines yet. Below is the text of the scope document as published.
Part 1 of 3
(A2LA Cert. No. 0098.09) Revised 6/29/2026 Page 1 of 2 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 MGA RESEARCH CORPORATION-TROY 1150 W. Maple Rd. Troy, MI 48084 Scott Arsen Phone: 248-577-5001 Email: scott.arsen@mgaresearch.com MECHANICAL Valid To: May 31, 2027 Certificate Number: 0098.09 In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory at the location listed above to perform the following tests on: automotive components (brackets, structural members, suspension components, seats, body panels and interior parts): Test and Test Parameters1: Test Method(s)/Standard(s): Axial and Bending, Monotonic Testing2 Force: up to 100 000 lbf. Displacement: up to 12 in. In Possible Environmental Conditions of (-40 to 180) °F RBA 245 (Axle Tech) Axial and Bending, Fatigue Testing2 Force: up to 100 000 lbf. Displacement: up to 12 in. In Possible Environmental Conditions of (-40 to 180) °F SAE J684 Torsional, Monotonic and Fatigue Testing2 Up to 8 000 ft⸱lbf, 20 000 RPM, and 50 HP In Possible Environmental Conditions of (-40 to 180) °F SOP-TR-PR-001 Environmental2 Temperature: (-40 to 180) °F using Various Chambers CEPT 01-03-L-311 Static Testing2 Static Bending and Torsion Displacement: Up to 2 in. Force application: Up to 11 000 lbf. Up to 64 Channels Acquisition (+/- 10 V) GMW-3067, GMW7699 Multi-Axis Simulation Table(s) (MAST)2 Up to 50 Hz Bounce, Vertical, Pitch, Roll, Yaw, Lateral and Longitudinal Inputs DVM 0009-ST
Part 2 of 3
(A2LA Cert. No. 0098.09) Revised 6/29/2026 Page 2 of 2 Test and Test Parameters: Test Method(s)/Standard(s): Vehicle and Laboratory Data Acquisition3 SOP-TR-PR-002 Four Post (Wheel) Road Simulation2 Up to 50 Hz Up to 55 kip Actuators SOP-TR-PR-003 Spindle-Coupled Road Simulation (329 LT)2 Up to 50 Hz SOP-TR-PR-004 Spindle-Coupled Road Simulation (329 PC)2 Up to 50 Hz SOP-TR-PR-005 Temperature2 High/Low/Cyclic Temperature without Humidity2 (-65 to 165) ºC Temperature Capability with Humidity2 (-50 to 150) ºC (30% to 95%) RH Thermal Shock2 (-50 to 150) ºC Single Chamber Dynamometer2 Driveline: Performance, Fatigue, Durability Up to 600 HP, Torque Up to 8,333 ft/lbs, Speed Up to 25,000 RPM Pressure2 0 to 1000 psi Liquid Flow2 up to 10 gpm Chemical Resistance2 Per customer specification 1This scope meets A2LA’s P112 Flexible Scope Policy. 2This laboratory also uses customer supplied test methods utilizing any combination of test equipment parameters listed above. 3This laboratory performs field testing activities for these tests.
Part 3 of 3
For the tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation. Accredited Laboratory A2LA has accredited MGA RESEARCH CORPORATION-TROY Troy, MI for technical competence in the field of Mechanical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 20th day of June 2025. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 0098.09 Valid to May 31, 2027 Revised June 29, 2026
Text extracted from the accredited scope document. Layout and tables from the original may not carry over; the scope document itself is the authoritative copy.
Location
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.