China
Shenzhen NTEK Testing Technology Co.,
No. 24 Xinfa East Road, Xiangshan Community, Xinqiao Street, Baoan District, Shenzhen, Guangdong, People's Republic of China, Shenzhen, Guangdong, China
A2LA|4298.01ISO/IEC 17025Register collected 2026-08-22
Certificates
1
Scope items
7
Locations
1
Contact this laboratory
Work at Shenzhen NTEK Testing Technology Co.,?
Claim this profile to keep it accurate.
Claim this profileRegister record
- A2LACollected
- 4298.01Active
Certificates and scope
1A2LA
ISO/IEC 17025
Active4298.01
Accredited scope, certificate 4298.01
| Discipline | Method | Matrix | Range |
|---|---|---|---|
| electrical | ANSI C63.4:2014; FCC MP-5 (February 1986); ANSI C63.10:2013; FCC KDB 905462 D02 (v02); ANSI/TIA-603-E; ANSI C63.26-2015; IEEE Std 1528:2013 | - | to 40000 MHz |
| electrical | IEC 62368-1; EN 62368-1; UL 62368-1; AS/NZS 62368.1 | - | - |
| electrical | CFR 47, FCC Part 15 Subpart B; ASNI C63.4:2014; ANSI C63.4-2014+ C63.4a-2017; CFR 47, FCC Part 18; MP-5:1986; VCCI-CISPR 32; ICES-001; ICES-003; ICES-005; EN 55011; CISPR 11; AS CISPR 11; J55011; GB 4824; CNS 13803; KS C 9811; EN 55013; CISPR 13; AS/NZS CISPR 13; J55013; GB 13837; CNS 13439; EN IEC 55014-1; CISPR 14-1; AS/NZS CISPR 14.1; J55014-1; GB 4343.1; CNS 13783-1; KS C 9814-1; EN IEC 55015; CISPR 15; AS CISPR 15; J55015; GB 17743; CNS 14115; KS C 9815; EN 55022; CISPR 22; AS/NZS CISPR 22; J55022; CNS 13438; KN 22; TCVN 7189; EN 55032; CISPR 32; AS/NZS CISPR 32; J55032; GB 9254.1; KS C 9832; IEC/EN 60601-1-2; IEC/EN 62493; EN IEC 62040-2; IEC 62040-2; EN IEC 61326-1; IEC 61326-1; EN IEC 61204-3; IEC 61204-3; EN IEC 61000-6-3; IEC 61000-6-3; KS C 9610-6-3; EN IEC 61000-6-4; IEC 61000-6-4; KS C 9610-6-4; RRA Public Notification 2017-19, Dec 28, 2017; RRA Announce 2017-71, Dec 28, 2017 | - | to 40 GHz |
| electrical | Article 2-1-11-7; Article 2-1-11-8; Article 2-1-11-19; Article 2-1-11-21; Article 2-1-19; Article 2-1-19-2; Articles 2-1-19-2-2 & 2-1-19-2-3; Article 2-1-19-3; Article 2-1-11-19-2; Article 2-1-11-19-3; Article 2-1-11-21; Article 2-1-54; Article 2-1-54-6; Article 2-1-11-30; Article 2-1-11-34; Article 2-1-11-31; Article 2-1-11-32; LP0002 (2020); PLMN01 (2020); PLMN08 (2020); HKCA 1002; HKCA 1007; HKCA 1008; HKTA 1019; HKCA 1033; HKCA 1039; HKCA 1041; HKCA 1042; HKCA 1044; HKCA 1048; HKCA 1049; HKCA 1053; HKCA 1054; HKCA 1056; HKCA 1057; HKCA 1061; HKCA 1073; IMDA TS SRD; IMDA TS CMT; IMDA TS UWB; IMDA TS LMR; QCVN 12; QCVN 15; QCVN 18; QCVN 47; QCVN 54; QCVN 55; QCVN 65; QCVN 86; QCVN 96; QCVN 112; EN 62209-1; IEC 62209-1; EN 62209-2; IEC 62209-2; EN 50566; EN 50360; EN 62479; IEC 62479; EN 62311; IEC 62311; IEEE 1528; IEC/IEEE 62209-1528; IEEE C95.1; KDB 865664; KDB 447498; RSS-102; RSS-102.SAR.MEAS; 47 CFR § 1.1310; 47 CFR. § 2.1091; 47 CFR § 2.1093; KDB 248227; KDB 615223; KDB 616217; KDB 643646; KDB 648474; KDB 941225; ACA Radio Communications Standards; GB 21288; YD/T 1644-1; YD/T 1644.2; CNS 14959; CNS 14958-1; AS/NZS 2772.1; AS/NZS 2772.2; Radio communications (Electromagnetic Radiation — Human Exposure) Standard 2014 Maximum Exposure Levels to Radiofrequency Field ARIB STD-T56; RRA Public Notification 2017-8 | - | - |
| electrical | - | - | - |
| - | - | - | - |
| - | - | - | - |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one.
Labs with overlapping accredited scope in China
- Shenzhen Tongzhou Testing Co.,ShenzhenA2LAShares 3 accredited test methodsANSI C63.4:2014CISPR 32IEC 62368-1
- CTC Laboratories, Inc.Shenzhen, GuangdongA2LAShares 2 accredited test methodsANSI C63.4:2014IEC 62368-1
- CTSL Testing (Dongguan) Co.,DongguanA2LAShares 2 accredited test methodsANSI C63.4:2014IEC 62368-1
- Eurofins TA Technology (Shanghai) Co.,Shanghai 201201A2LAShares 2 accredited test methodsANSI C63.4:2014IEC 62368-1
- Hwa-Hsing (Dongguan) Testing Co.,GuangdongA2LAShares 2 accredited test methodsANSI C63.4:2014IEC 62368-1
Accreditation data collected from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.