Trescal, Inc. - Charlotte, NC
10442 BAILEY ROAD, SUITE B, 28031, Cornelius, NC, United States
Visit website- Scope lines
- 39
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 39 scope lines.
A2LA certificate 1877.01 · 39 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ANSI/NCSL Z540.3-2006 | pH buffer solutions | 0 to 60 ° |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 2 of 38
Parameter/Equipment
Range
CMC2 (±)
Comments
Depth Gages3, 9
Up to 40 in
13 µin + 5.1 µin/in
Gage blocks
Indicators3, 9
Up to 2 in
17 µin + 2.3 µin/in
Gage blocks
Height Gages3, 9
Up to 40 in
13 µin + 5.4 µin/in
Gage blocks
Calipers3, 9 –
Outside
Step/Depth
Inside
Up to 40 in
Up to 40 in
Up to 1 in
12 µin + 5.1 µin/in
13 µin + 5.1 µin/in
44 µin
Gage blocks
Gage blocks,
accessories
Micrometers3, 9 –
Linearity
Flatness
Up to 40 in
50 µin
8.7 µin + 5.2 µin/in
5.5 µin
Gage blocks
Optical flat
Tape Measure & Steel
Ruler3, 9
Up to 39 in
36 in to 100 ft
0.0023 in
0.0023 in + 11 µin/in
Rigid ruler, gage
blocks, jeweler’s loupe;
no tension applied.
III. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
DC Voltage3, 6 –
Generate
Up to 220 mV
(0.22 to 2.2) V
(2.2 to 11) V
(11 to 22) V
(22 to 220) V
(220 to 1100) V
0.49 µV + 5.7 nV/mV
0.8 µV + 3.5 µV/V
2.9 µV + 2.5 µV/V
4.3 µV + 2.5 µV/V
43 µV + 3.5 µV/V
0.42 mV + 4.5 µV/V
Fluke 5720A | to 40 in |
| 3 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 3 of 38
Parameter/Equipment
Range
CMC2, 4, 5 (±)
Comments
DC Voltage3, 6 –
Generate (cont)
(0 to 120) mV
(0 to 1.2) V
(0 to 12) V
(0 to 120) V
(0 to 1020) V
0.8 µV + 9.3 µV/V
1.9 µV + 5.8 µV/V
10 µV + 6.2 µV/V
0.1 mV + 8.5 µV/V
1 mV + 8.5 µV/V
Fluke 5560A
DC Voltage3 – Measure
Up to 200 mV
200 mV to 2 V
(2 to 20) V
(20 to 200) V
(200 to 1000) V
0.11 µV + 5 pV/mV
5.1 µV + 3.6 µV/V
5.3 µV + 3.4 µV/V
0.86 mV + 2.8 µV/V
0.93 mV + 5.1 µV/V
Fluke 8508A
DC High Voltage3 –
Measure
(1 to 10) kV
(10 to 70) kV
3.2 V + 0.17 V/kV
8.7 V + 0.45 V/kV
Vitrek 4700 HV
meter with Vitrek
HVL-70 probe.
DC Current3, 6 –
Generate
Clamp Meters
3
Up to 220 µA
(0.22 to 2.2) mA
(2.2 to 22) mA
(22 to 220) mA
(0.22 to 2.2) A
(2.2 to 11) A
(11 to 20.5) A
(0 to 120) µA
(0 to 1.2) mA
(0 to 12) mA
(0 to 120) mA
(0 to 1.2) A
(0 to 3.1) A
(0 to 12) A
(0 to 30.2) A
(10 to 16.5) A
(16.5 to 150) A
(150 to 1025) A
(1000 to 5000) A
6 nA + 35 pA/µA
7.1 nA + 30 nA/mA
41 nA + 30 nA/mA
0.73 µA + 50 nA/mA
12 µA + 0.11 mA/A
0.49 mA + 0.34 mA/A
9.4 mA + 0.8 mA/A
6 nA + 97 µA/A
15 nA + 78 µA/A
82 nA + 78 µA/A
0.82 µA + 78 µA/A
10 µA + 0.12 mA/A
0.15 mA + 0.23 mA/A
0.25 mA + 0.23 mA/A
0.5 mA + 0.78 mA/A
50 mA + 6.5 mA/A
0.18 A + 3.4 mA/A
0.83 A + 3.3 mA/A
1.2 A + 4.6 mA/A
Fluke 5720A
w/5725A
Fluke 552XA
Fluke 5560A
Fluke 5212XA with
5500/coil
Fluke 52120 with coil
6KA
DC Current – Generate
(1 to 100) nA
100 nA to 1 µA
(1 to 10) µA
0.37 %
0.25 %
0.062 %
5720A, IET standard
resistors | 0 to 1020 V |
| 4 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 4 of 38
Parameter/Equipment
Range
CMC2, 4, 5 (±)
Comments
DC Current3 – Measure
Up to 200 µA
200 µA to 2 mA
(2 to 20) mA
(20 to 200) mA
200 mA to 2 A
(2 to 20) A
2.4 nA + 6.4 pA/A
6 nA + 11 nA/A
32 nA + 14 nA/A
0.63 µA + 47 nA/A
14 µA + 0.18 mA/A
0.33 mA + 0.55 mA/A
Fluke 8508A
DC Power3 – Generate
Up to 330 µA
Up to 3.3 mA
Up to 33 mA
Up to 330 mA
Up to 1.1 A
Up to 3 A
Up to 11 A
Up to 20.5 A
Up to 120 µA
Up to 1.2 mA
Up to 12 mA
Up to 120 mA
Up to 1.2 A
Up to 3.1 A
Up to 12 A
Up to 30.2 A
Up to 1020 V
Up to 337 mW
(0.337 to 3.366) W
(3.366 to 33.66) W
(33.66 to 336.6) W
(0.3366 to 1.122) kW
(1.122 to 3.06) kW
(3.06 to 11.22) kW
(11.22 to 20.91) kW
Up to 122 mW
(0.12 to 1.224) W
(1.225 to 12.24) W
(12.24 to 122.4) W
(0.1224 to 1.224) kW
(1.224 to 3.162) kW
(3.162 to 12.24) kW
(12.24 to 30.8) kW
0.017 %
0.021 %
0.0093 %
0.0093 %
0.019 %
0.043 %
0.044 %
0.13 %
0.015 %
0.0092 %
0.0087 %
0.0087 %
0.013 %
0.028 %
0.025 %
0.08 %
Fluke 5520A
Fluke 5560A
DC Resistance3, 6 –
Generate
(0 to 10.9999) Ω
(11 to 32.9999) Ω
(33 to 109.9999) Ω
(110 to 329.9999) Ω
(330 to 1099.999) Ω
(1.1 to 3.299 999) kΩ
(3.3 to 10.999 99) kΩ
(11 to 32.999 99) kΩ
(33 to 109.9999) kΩ
(110 to 329.9999) kΩ
(330 to 1099.999) kΩ
(1.1 to 3.299 999) MΩ
(3.3 to 10.999 99) MΩ
(11 to 32.999 99) MΩ
(33 to 109.9999) MΩ
(110 to 329.9999) MΩ
(330 to 1100) MΩ
1.2 mΩ + 24 µΩ/Ω
1.5 mΩ + 24 µΩ/Ω
1.9 mΩ + 22 µΩ/Ω
4.1 mΩ + 22 µΩ/Ω
9.1 mΩ + 22 µΩ/Ω
41 mΩ + 22 µΩ/Ω
92 mΩ + 22 µΩ/Ω
0.41 Ω + 22 µΩ/Ω
0.9 Ω + 22 µΩ/Ω
8.4 Ω + 26 µΩ/Ω
14 Ω + 26 µΩ/Ω
93 Ω + 48 µΩ/Ω
0.4 kΩ + 0.1 mΩ/Ω
4.4 kΩ + 0.2 mΩ/Ω
16 kΩ + 0.4 mΩ/Ω
0.35 MΩ + 2.4 mΩ/Ω
4.4 MΩ + 12 mΩ/Ω
Fluke 552XA | to 20.5 A |
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 5 of 38
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
DC Resistance3, 6 –
Generate (cont)
Calibration of High
Voltage Megohm
Meters
Fixed Points
(0 to 12) Ω
(12 to 120) Ω
120 Ω to 1.2 kΩ
(1.2 to 12) kΩ
(12 to 120) kΩ
120 kΩ to 1.2 MΩ
(1.2 to 12) MΩ
(12 to 120) MΩ
(120 to 1200) MΩ
1 Ω
1.8 Ω
3.7 Ω
5.9 Ω
10 Ω
18 Ω
37 Ω
59 Ω
100 Ω
180 Ω
370 Ω
590 Ω
1 kΩ
1.8 kΩ
3.7 kΩ
5.9 kΩ
18.24 GΩ
(10 to 99.99) kΩ
(100 to 999.9) kΩ
(1 to 9.99) MΩ
(10 to 99.99) MΩ
(100 to 999.9) MΩ
(1 to 10.05) GΩ
0 Ω
1 Ω
1.9 Ω
10 Ω
19 Ω
100 Ω
190 Ω
1 kΩ
1.9 kΩ
10 kΩ
19 kΩ
100 kΩ
190 kΩ
1 mΩ + 19 µΩ/Ω
1.2 mΩ + 19 µΩ/Ω
4.4 mΩ + 19 µΩ/Ω
44 mΩ + 19 µΩ/Ω
0.44 Ω + 19 µΩ/Ω
4.4 Ω + 19 µΩ/Ω
63 Ω + 27 µΩ/Ω
6.5 kΩ + 0.33 mΩ/Ω
0.47 MΩ + 3.1 mΩ/Ω
11 mΩ
15 mΩ
22 mΩ
30 mΩ
46 mΩ
78 mΩ
0.16 Ω
0.29 Ω
0.46 Ω
0.78 Ω
1.6 Ω
2.1 Ω
3.1 Ω
4.1 Ω
5.4 Ω
6.2 Ω
0.6 GΩ
22 Ω + 2.1 mΩ/Ω
0.22 kΩ + 2.1 mΩ/Ω
3.2 kΩ + 3.1 mΩ/Ω
52 kΩ + 5.2 mΩ/Ω
0.52 MΩ + 5.2 mΩ/Ω
10 MΩ + 10 mΩ/Ω
50 µΩ
95 µΩ
0.18 mΩ
0.26 mΩ
0.48 mΩ
1.1 mΩ
2 mΩ
9 mΩ
17 mΩ
90 mΩ
0.17 Ω
1.1 Ω
2.1 Ω
Fluke 5560A
Fluke 5080A/MEG
Fluke 5720A | ||
| 6 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 6 of 38
Parameter/Equipment
Range
CMC2, 4, 5 (±)
Comments
DC Resistance3, 6 – Generate
(cont)
Fixed Points
1 MΩ
1.9 MΩ
10 MΩ
19 MΩ
100 MΩ
18 Ω
36 Ω
0.37 kΩ
0.89 kΩ
10 kΩ
Fluke 5720A
DC Resistance3 –
Generate, Fixed
Points, High Voltage
Up to 20 V
Up to 100 V
Up to 1000 V
Up to 5000 V
1 kΩ
10 kΩ
100 kΩ
1 MΩ
10 MΩ
100 MΩ
1 GΩ
10 GΩ
100 GΩ
1 TΩ
10 MΩ
100 MΩ
1 GΩ
10 GΩ
100 GΩ
1 TΩ
0.0013 %
0.0013 %
0.0013 %
0.0022 %
0.004 %
0.012 %
0.062 %
0.24 %
0.36 %
0.51 %
0.54 %
0.5 %
0.5 %
0.5 %
0.51 %
0.51 %
IET VRS-100-10-
1K-BP
DC Resistance3 – Generate,
Fixed Points to Calibrate
Thermometer Digital Readouts
1 Ω
25 Ω
75 Ω
100 Ω
200 Ω
400 Ω
1 kΩ
10 kΩ
2.8 µΩ
23 µΩ
70 µΩ
96 µΩ
0.19 mΩ
0.37 mΩ
2.5 mΩ
31 mΩ
Standard resistors | to 5000 V |
| 7 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 7 of 38
Parameter/Equipment
Range
CMC2, 4, 5 (±)
Comments
Resistance3 – Measure
Up to 2 Ω
(2 to 20) Ω
(20 to 200) Ω
200 Ω to 2 kΩ
(2 to 20) kΩ
(20 to 200) kΩ
200 kΩ to 2 MΩ
(2 to 20) MΩ
(20 to 200) MΩ
200 MΩ to 2 GΩ
(2 to 20) GΩ
4.7 µΩ + 17 µΩ/Ω
48 µΩ + 7.9 µΩ/Ω
0.13 mΩ + 7.4 µΩ/Ω
0.47 mΩ + 7.8 µΩ/Ω
14 mΩ + 7.8 µΩ/Ω
4.7 mΩ + 7.8 µΩ/Ω
0.93 Ω + 10 µΩ/Ω
93 Ω + 21 µΩ/Ω
9.3 kΩ + 0.12 mΩ/Ω
0.93 MΩ + 1.4 mΩ/Ω
9.3 MΩ + 1.4 mΩ/Ω
Fluke 8508A
Resistance3 – Measure
333 µΩ
1 mΩ
10 mΩ
100 mΩ
1 Ω
10 Ω
100 Ω
1 kΩ
10 KΩ
0.0063 %
0.0066 %
0.0023 %
0.0031 %
0.0016 %
0.0016 %
0.0016 %
0.0016 %
0.0016 %
Current transfer
using standard shunt,
Agilent 3458A
Electrical Calibration of
Thermocouple Indicators3 –
Type B
Type C
Type E
Type J
(600 to 800) °C
(800 to 1550) °C
(1550 to 1820) °C
(0 to 1000) °C
(1000 to 1800) °C
(1800 to 2000) °C
(2000 to 2316) °C
(-250 to -200) °C
(-200 to -100) °C
(-100 to 0) °C
(0 to 600) °C
(600 to 1000) °C
(-210 to -100) °C
(-100 to 800) °C
(800 to 1200) °C
0.35 °C
0.28 °C
0.23 °C
0.16 °C
0.23 °C
0.27 °C
0.36 °C
0.25 °C
0.12 °C
0.091 °C
0.082 °C
0.1 °C
0.14 °C
0.091 °C
0.11 °C
Fluke 7526A | to 2 Ω |
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 8 of 38
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Calibration
of Thermocouple
Indicators
3 – (cont)
Type K
Type L
Type N
Type R
Type S
Type T
Type U
(-250 to -200) °C
(-200 to -100) °C
(-100 to 500) °C
(500 to 800) °C
(800 to 1372) °C
(-200 to -100) °C
(-100 to 900) °C
(-250 to -200) °C
(-200 to -100) °C
(-100 to 0) °C
(0 to 100) °C
(100 to 800) °C
(800 to 1300) °C
(50 to -25) °C
(-25 to 0) °C
(0 to 100) °C
(100 to 400) °C
(400 to 600) °C
(600 to 1000) °C
(1000 to 1600) °C
(1600 to 1767) °C
(-50 to -25) °C
(-25 to 0) °C
(0 to 100) °C
(100 to 400) °C
(400 to 600) °C
(600 to 1000) °C
(1000 to 1600) °C
(1600 to 1767) °C
(-250 to -200) °C
(-200 to -100) °C
(-100 to 0) °C
(0 to 200) °C
(200 to 400) °C
(-200 to 0) °C
(0 to 200) °C
(200 to 600) °C
0.46 °C
0.16 °C
0.1 °C
0.1 °C
0.13 °C
0.1 °C
0.091 °C
0.73 °C
0.23 °C
0.12 °C
0.11 °C
0.1 °C
0.13 °C
0.55 °C
0.45 °C
0.39 °C
0.28 °C
0.22 °C
0.21 °C
0.2 °C
0.24 °C
0.51 °C
0.43 °C
0.38 °C
0.29 °C
0.23 °C
0.22 °C
0.22 °C
0.27 °C
0.35 °C
0.16 °C
0.14 °C
0.12 °C
0.12 °C
0.23 °C
0.1 °C
0.1 °C
Fluke 7526A | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 9 of 38
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Calibration of
RTDs3 Indicating Systems –
Pt 385, 100 Ω
Pt 3926, 100 Ω
Pt 3916, 100 Ω
Pt 385, 200 Ω
Pt 385, 500 Ω
Pt 385, 1000 Ω
Ni 120, 120 Ω
Cu 427, 10 Ω
(-200 to 80) °C
(-80 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 800) °C
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(-200 to -190) °C
(-190 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 630) °C
(-200 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(-200 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(-80 to 260) °C
(-100 to 260) °C
0.018 °C
0.023 °C
0.026 °C
0.029 °C
0.035 °C
0.042 °C
0.016 °C
0.018 °C
0.020 °C
0.024 °C
0.028 °C
0.035 °C
0.015 °C
0.016 °C
0.019 °C
0.019 °C
0.025 °C
0.028 °C
0.033 °C
0.037 °C
0.054 °C
0.057 °C
0.061 °C
0.061 °C
0.070 °C
0.072 °C
0.089 °C
0.028 °C
0.029 °C
0.036 °C
0.040 °C
0.047 °C
0.019 °C
0.020 °C
0.027 °C
0.028 °C
0.035 °C
0.010 °C
0.12 °C
Fluke 7526A | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 10 of 38
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Calibration
of Thermocouple
Indicators3
Type B
Type C
Type E
Type J
Type K
Type N
(250 to < 350) °C
(350 to < 445) °C
(445 to < 580) °C
(580 to < 780) °C
(750 to < 1000) °C
(1000 to 1820) °C
(0 to < 250) °C
(250 to < 1000) °C
(1000 to < 1500) °C
(1500 to < 1800) °C
(1800 to < 2000) °C
(2000 to < 2250) °C
(2250 to 2315) °C
(-270 to < -245) °C
(-245 to < -195) °C
(-195 to < -155) °C
(-155 to < -90) °C
(-90 to < 15) °C
(15 to < 890) °C
(890 to 1000) °C
(-210 to < -180) °C
(180 to < -120) °C
(-120 to < -50) °C
(-50 to < 990) °C
(990 to 1200) °C
(-270 to < -255) °C
(-255 to < -195) °C
(-195 to < -115) °C
(-115 to < -55) °C
(-55 to < 1000) °C
(1000 to 1372) °C
(-270 to < -260) °C
(-260 to < -200) °C
(-200 to < -140) °C
(-140 to < -70) °C
(-70 to 25) °C
(25 to < 160) °C
(160 to 1300) °C
0.95 °C
0.74 °C
0.58 °C
0.46 °C
0.38 °C
0.3 °C
0.21 °C
0.17 °C
0.19 °C
0.22 °C
0.24 °C
0.3 °C
0.33 °C
1.2 °C
0.18 °C
0.1 °C
0.082 °C
0.073 °C
0.063 °C
0.07 °C
0.12 °C
0.1 °C
0.083 °C
0.073 °C
0.07 °C
2.2 °C
0.7 °C
0.12 °C
0.092 °C
0.073 °C
0.083 °C
5 °C
1 °C
0.23 °C
0.16 °C
0.13 °C
0.11 °C
0.1 °C
Ectron 1140A | ||
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 11 of 38
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Calibration
of Thermocouple
Indicators3 – (cont)
Type R
Type S
Type T
(-50 to < -30) °C
(-30 to < 45) °C
(45 to < 160) °C
(160 to < 380) °C
(380 to < 775) °C
(775 to 1768) °C
(-50 to < -30) °C
(-30 to < 45) °C
(45 to < 105) °C
(105 to < 310) °C
(310 to < 615) °C
(615 to 1768) °C
(-270 to < -255) °C
(-255 to < -240) °C
(-240 to < -210) °C
(-210 to < -150) °C
(-150 to < -40) °C
(-40 to < 100) °C
(100 to 400) °C
0.65 °C
0.55 °C
0.41 °C
0.31 °C
0.27 °C
0.23 °C
0.62 °C
0.56 °C
0.41 °C
0.34 °C
0.3 °C
0.27 °C
1.8 °C
0.49 °C
0.3 °C
0.18 °C
0.12 °C
0.085 °C
0.08 °C
Ectron 1140A
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Voltage3, 6 –
Generate
Up to 2.2 mV
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
4 µV + 0.33 µV/mV
4 µV + 85 nV/mV
4 µV + 75 nV/mV
4 µV + 0.18 µV/mV
5 µV + 0.46 µV/mV
10 µV + 0.9 µV/mV
20 µV + 1.2 µV/mV
20 µV + 2.5 µV/mV
Fluke 5720A | ||
| 12 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 12 of 38
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Voltage3, 6 – Generate
(cont)
(2.2 to 22) mV
(22 to 220) mV
220 mV to 2.2 V
(2.2 to 22) V
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
4.5 µV + 0.22 µV/mV
4.2 µV + 85 nV/mV
4.2 µV + 75 nV/mV
4.4 µV + 0.18 µV/mV
6.1 µV + 0.46 µV/mV
12 µV + 0.9 µV/mV
23 µV + 1.2 µV/mV
26 µV + 2.5 µV/mV
17 µV + 0.22 µV/mV
9 µV + 85 nV/mV
8.7 µV + 75 nV/mV
11 µV + 0.18 µV/mV
16 µV + 0.46 µV/mV
31 µV + 0.9 µV/mV
48 µV + 1.2 µV/mV
78 µV + 2.5 µV/mV
90 µV + 0.22 mV/V
34 µV + 79 µV/V
18 µV + 39 µV/V
26 µV + 70 µV/V
54 µV + 0.11 mV/V
0.16 mV + 0.34 mV/V
0.56 mV + 0.83 mV/V
0.64 mV + 1.5 mV/V
0.89 mV + 0.22 mV/V
0.34 mV + 80 µV/V
0.15 mV + 40 µV/V
0.26 mV + 70 µV/V
0.41 mV + 0.1 mV/V
1.2 mV + 0.26 mV/V
4 mV + 0.9 mV/V
6.1 mV + 1.3 mV/V
Fluke 5720A | ||
| 13 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 13 of 38
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Voltage3, 6 – Generate
(cont)
(22 to 220) V*
(220 to 750) V
(220 to 1100) V
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(30 to 50) kHz
(50 to 100) kHz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 30) kHz
8.9 mV + 0.22 mV/V
3.4 mV + 80 µV/V
1.7 mV + 47 µV/V
3.5 mV + 72 µV/V
5.9 mV + 0.13 mV/V
34 mV + 0.8 mV/V
0.13 V + 4.2 mV/V
0.24 V + 7 mV/V
93 mV + 0.36 mV/V
0.34 V + 1.3 mV/V
22 mV + 80 µV/V
34 mV + 0.13 mV/V
93 mV + 0.36 mV/V
Fluke 5720A
* 220 V range
subject to 2.2E7 V-
Hz limitation
w/ 5725A
AC Voltage – Generate3
(1 to 12) mV
(12 to 120) mV
(0.12 to 1.2) V
(0.01 to 3) Hz
(3 to 5) Hz
(5 to 10) Hz
10 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.01 to 3) Hz
(3 to 5) Hz
(5 to 10) Hz
10 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.01 to 3) Hz
(3 to 5) Hz
(5 to 10) Hz
(10 to 40) Hz
40.01 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
0.11 mV + 50 mV/V
8.9 µV + 1.9 mV/V
7.7 µV + 0.68 mV/V
6.1 µV + 0.12 mV/V
6.3 µV + 0.29 mV/V
16 µV + 1.2 mV/V
36 µV + 6.2 mV/V
36 µV + 6.2 mV/V
1.2 mV + 50 mV/V
30 µV + 1.9 mV/V
15 µV + 0.68 mV/V
7.4 µV + 0.11 mV/V
11 µV + 0.27 mV/V
28 µV + 0.62 mV/V
49 µV + 1.6 mV/V
49 µV + 1.6 mV/V
12 mV + 50 mV/V
0.3 mV + 1.9 mV/V
0.15 mV + 0.68 mV/V
74 µV + 0.11 mV/V
21 µV + 0.11 mV/V
42 µV + 0.23 mV/V
0.11 mV + 0.54 mV/V
0.26 mV + 1.5 mV/V
0.26 mV + 1.5 mV/V
Fluke 5560A | ||
| 14 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 14 of 38
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Voltage – Generate3
(cont)
(1.2 to 12) V
(12 to 120) V
(120 to 330) V
(330 to 1020) V
(0.01 to 3) Hz
(3 to 5) Hz
(5 to 10) Hz
(10 to 40) Hz
40.01 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.01 to 3) Hz
(3 to 5) Hz
(5 to 10) Hz
(10 to 40) Hz
40.01 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz *
(3 to 5) Hz
(5 to 10) Hz
10 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(3 to 5) Hz
(5 to 10) Hz
10 Hz to 10 kHz
0.12 V + 50 mV/V
3 mV + 1.9 mV/V
1.6 mV + 0.68 mV/V
0.49 mV + 0.11 mV/V
0.18 mV + 0.11 mV/V
0.33 mV + 0.23 mV/V
0.77 mV + 0.54 mV/V
2.5 mV + 1.6 mV/V
2.5 mV + 1.6 mV/V
1.2 V + 50 mV/V
30 mV + 1.9 mV/V
16 mV + 0.68 mV/V
4.8 mV + 0.11 mV/V
1.8 mV + 0.11 mV/V
3.3 mV + 0.23 mV/V
7.7 mV + 0.54 mV/V
39 mV + 1.6 mV/V
0.3 V + 1.9 mV/V
0.16 V + 0.68 mV/V
21 mV + 0.11 mV/V
36 mV + 0.23 mV/V
0.16 V + 1.2 mV/V
0.7 V + 1.9 mV/V
0.3 V + 0.68 mV/V
0.12 V + 0.11 mV/V
Fluke 5560A
* Max output 70 V
AC Voltage3 – Measure
Up to 200 mV
(1 to 10) Hz
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
13 µV + 0.16 µV/V
4 µV + 0.12 µV/V
4.1µV + 0.1 µV/V
2.1 µV + 0.1 µV/V
4.1 µV + 0.13 µV/V
7.9 µV + 0.31 µV/V
19 µV + 0.66 µV/V
Fluke 8508A | ||
| 15 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 15 of 38
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Voltage3 – Measure
(cont)
200 mV to 2 V
(2 to 20) V
(20 to 200) V
(200 to 1050) V
(1 to 10) Hz
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
(1 to 10) Hz
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
(1 to 10) Hz
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
(1 to 10) Hz
(10 to 40) Hz
40 Hz to 10 kHz
(10 to 30) kHz
(30 to 100) kHz
0.15 mV + 0.15 mV/V
30 µV + 0.11 mV/V
28 µV + 88 µV/V
26 µV + 74 µV/V
31 µV + 0.11 mV/V
0.27 mV + 0.13 mV/V
0.24 mV + 0.51 mV/V
2.1 mV + 2.3 mV/V
0.24 mV + .016 mV/V
0.11 mV + 0.12 mV/V
0.29 mV + 78 µV/V
40 µV + 74 µV/V
72 µV + 0.11 mV/V
0.1 mV + 0.21 mV/V
0.25 mV + 0.51 mV/V
2.1 mV + 2.3 mV/V
11 mV + 0.16 mV/V
2.0 mV + 0.12 mV/V
2.0 mV + 90 µV/V
1.9 mV + 76 µV/V
2 mV + 0.11 mV/V
4.1 mV + 0.21 mV/V
19 mV + 0.51 mV/V
0.19 V + 2.3 mV/V
67 mV + 0.15 mV/V
26 mV + 0.11 mV/V
3300 mV + 0.11 mV/V
49 mV + 0.2 mV/V
0.21 V + 0.54 mV/V
Fluke 8508A
AC High Voltage3, 6 –
Measure
(1 to 10) kVrms
60 Hz
(10 to 50) kVrms
60 Hz
9.6 V + 0.8 V/kV
14 V + 1.2 V/kV
Vitrek 4700 HV
meter with Vitrek
HVL-70 probe | ||
| 16 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 16 of 38
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Current3, 6 – Generate
Up to 220 µA
220 µA to 2.2 mA
(2.2 to 22) mA
(22 to 220) mA
220 mA to 2.2 A
(2.2 to 11) A
(11 to 20.5) A
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
20 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
63 nA + 0.13 nA/µA
12 nA + 0.14 nA/µA
9 nA + 0.11 nA/µA
15 nA + 0.25 nA/µA
75 nA + 0.9 nA/µA
0.69 µA + 13 nA/µA
93 nA + 0.23 µA/mA
67 nA + 0.14 µA/mA
60 nA + 0.11 µA/mA
0.15 µA + 0.18 µA/mA
0.85 µA + 0.9 µA/mA
3.4 µA + 8 µA/mA
0.92 µA + 0.23 µA/mA
0.69 µA + 0.14 µA/mA
0.6 µA + 0.11 µA/mA
0.95 µA + 0.18 µA/mA
7 µA + 0.9 µA/mA
14 µA + 3.2 µA/A
9.3 µA + 0.23 µA/mA
6.8 µA + 0.14 µA/mA
5 µA + 0.11 µA/mA
7.5 µA + 0.18 µA/mA
30 µA + 0.9 µA/mA
0.27 mA + 3.2 µA/mA
89 µA + 0.24 mA/A
0.17 mA + 0.39 mA/A
1.5 mA + 6 mA/A
1.1 mA + 0.4 mA/A
2.3 mA + 0.85 mA/A
8 mA + 3.3 mA/A
15 mA + 0.96 mA/A
17 mA + 1.2 mA/A
0.27 A + 24 mA/A
Fluke 5720A
Fluke 552XA
Fluke 5720A
Fluke 552XA
Fluke 5720A
Fluke 552XA
Fluke 5720A
Fluke 552XA
Fluke 5720A
5720A w/5725A
552XA | to 20.5 A |
| 17 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 17 of 38
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Current – Generate3
(12 to 120) µA
(0.12 to 1.2) mA
(1.2 to 12) mA
(12 to 120) mA
(0.12 to 1.2) A
(1.2 to 3.1) A
(3.1 to 12) A
(12 to 30) A
(3 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(3 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(3 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(3 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(3 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(3 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(3 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(3 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
12 nA + 0.19 mA/A
12 nA + 0.19 mA/A
12 nA + 0.19 mA/A
52 nA + 1.2 mA/A
1 µA + 3.9 mA/A
0.13 µA + 0.19 mA/A
0.13 µA + 0.19 mA/A
0.13 µA + 0.19 mA/A
0.25 µA + 1.2 mA/A
5.5 µA + 3.9 mA/A
1.3 µA + 0.19 mA/A
1.3 µA + 0.19 mA/A
1.3 µA + 0.19 mA/A
2.5 µA + 1.2 mA/A
15 µA + 3.9 mA/A
13 µA + 0.19 mA/A
6.5 µA + 0.12 mA/A
10 µA + 0.19 mA/A
25 µA + 1.2 mA/A
0.15 mA + 3.9 mA/A
0.13 mA + 0.18 mA/A
75 µA + 0.19 mA/A
0.1 mA + 0.19 mA/A
0.53 mA + 1.9 mA/A
0.77 mA + 3.9 mA/A
0.85 mA + 0.29 mA/A
0.58 mA + 0.23 mA/A
0.65 mA + 0.29 mA/A
2.8 mA + 1.9 mA/A
1.9 mA + 0.29 mA/A
1.2 mA + 0.23 mA/A
1.7 mA + 0.29 mA/A
6.9 mA + 1.9 mA/A
19 mA + 0.78 mA/A
15 mA + 0.54 mA/A
55 mA + 3.9 mA/A
Fluke 5560A | ||
| 18 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 18 of 38
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Current Clamps –
Toroidal:
(10 to 16.5) A
(16.5 to 150) A
(150 to 1025) A
(10 to 16.5) A
(16.5 to 150) A
(150 to 1025) A
Non-Toroidal:
(10 to 16.5) A
(16.5 to 150) A
(150 to 1025) A
(10 to 16.5) A
(16.5 to 150) A
(150 to 1025) A
(120 to 6000) A
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
10 Hz to 1 kHz
26 mA + 2.1 mA/A
50 mA + 1.9 mA/A
0.34 A + 1.9 mA/A
60 mA + 6 mA/A
0.11 A + 5.3 mA/A
0.86 A + 5.3 mA/A
60 mA + 3.8 mA/A
0.23 A + 3.7 mA/A
1.2 A + 3.7 mA/A
90 mA + 7.2 mA/A
0.28 A + 6.7 mA/A
1.6 A + 6.7 mA/A
1 A + 4.7 mA/A
Fluke 552XA with
5500A/coil
Fluke 552XA with
5500A/coil
52120A with coil
6KA
AC Current3 – Measure
Up to 200 µA
200 µA to 2 mA
(2 to 20) mA
(20 to 200) mA
(1 to 10) Hz
10 Hz to 10 kHz
(10 to 30) kHz
(30 to 100) kHz
(1 to 10) Hz
10 Hz to 10 kHz
(10 to 30) kHz
(30 to 100) kHz
(1 to 10) Hz
10 Hz to 10 kHz
(10 to 30) kHz
(30 to 100) kHz
(1 to 10) Hz
10 Hz to 10 kHz
(10 to 30) kHz
0.23 µA + 0.13 nA/A
19 nA + 48 pA/A
19 nA + 62 pA/A
19 nA + 3.1 nA/A
0.42 µA + 0.25 µA/A
0.56 µA + 0.19 µA/A
0.25 µA + 0.62 µA/A
0.5 µA + 3.1 µA/A
48 µA + 32 nA/A
1.9 µA + 0.29 µA/A
1.9 µA + 0.62 µA/A
2.2 µA + 3.1 µA/A
24 µA + 0.29 µA/A
19 µA + 0.28 µA/A
19 µA + 0.57 µA/A
Fluke 8508A | 10 to 1025 A |
| 19 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 19 of 38
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Current3 –
Measure (cont)
200 mA to 2 A
(2 to 20) A
(1 to 10) Hz
10 Hz to 10 kHz
(10 to 30) kHz
10 Hz to 2 kHz
(2 to 10) kHz
0.4 mA + 0.5 mA/A
0.26 mA + 0.67 mA/A
0.42 mA + 2.5 mA/A
1.9 mA + 0.72 mA/A
2.1 mA + 1.9 mA/A
Fluke 8508A
AC Resistance3 –
Generate, Fixed
Points
DC to 13 MHz
See matrix below.
Interpolate CMC’s for
frequencies between
stated cardinal points.
HP 16074A
0 Ω 0.1 Ω 1 Ω 10 Ω 100 Ω 1 kΩ 10 kΩ 100 kΩ
DC 6.6 % 0.0061 % 0.0023 % 0.00087 % 0.000 61 % 0.000 87 %
100 Hz
0.0037 %
0.0035 %
0.0021
0.000 35 %
1 kHz 0.0035 %
10 kHz 0.0035 %
100 kHz 0.0035 %
1 MHz 0.0037 % 0.0023 % 0.0011 %
2 MHz 0.0053 % 0.0045 % 0.004 %
3 MHz 0.0096 % 0.0097 % 0.0092 % 0.009 %
5 MHz 0.025 %
10 MHz 0.1 %
13 MHz 0.17 %
Parameter/Equipment
Range
CMC2, 4, 5 (±)
Comments
Duty Cycle3 –
Generate
(1 to 9.99) %
(10 to 49.99) %
50 %
(50.01 to 90) %
(90.01 to 99)
0.32 %
0.02 %
0.013 %
0.02 %
0.31 %
Fluke 5522A | ||
| 20 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 20 of 38
Parameter/Range
Frequency
CMC2, 4, 5 (±)
Comments
AC Power3 –
Generate
See Table below
See Table below
Fluke 5520A
(45 to 65) Hz (3.366 to
33.66) W
(33.66 to
336.6) W
(0.3366
to 1.122)
kW
(1.122 to
3.06) kW
(3.06 to
11.22) kW
(11.22 to 20.9)
kW
Ø 0°
PF=1.000 0.052 % 0.068 % 0.076 % 0.083 % 0.17 %
Ø 10°
PF=0.985 0.06 % 0.075 % 0.082 % 0.088 % 0.18 %
Ø 20°
PF=0.940 0.082 % 0.093 % 0.099 % 0.1 % 0.18 %
Ø 30°
PF=0.866 0.11 % 0.12 % 0.13 % 0.2 %
Ø 40°
PF=0.766 0.16 % 0.17 % 0.23 %
Ø 50°
PF=0.643 0.21 % 0.22 % 0.27 %
Ø 60°
PF=0.500 0.31 % 0.35 %
(45 to 65) Hz (3.366 to
33.66) W
(33.66 to
336.6) W
(0.3366
to 1.122)
kW
(1.122 to
3.06) kW
(3.06 to
11.22) kW
(11.22 to 20.9)
kW
Ø 70°
PF=0.342 0.48 % 0.49 % 0.51 %
Ø 80°
PF=0.174 0.99 % 1 %
(65 to 500) Hz (33.66 to
336.6) W
(0.3366 to
1.122) kW
(1.122 to 3.06)
kW
(3.06 to 11.22)
kW
(11.22 to 20.9)
kW
Ø 0°
PF=1.000 0.052 % 0.068 % 0.076 % 0.12 % 0.21 %
Ø 10°
PF=0.985 0.094 % 0.1 % 0.11 % 0.14 % 0.22 %
Ø 20°
PF=0.940 0.17 % 0.18 % 0.2 % 0.26 %
Ø 30°
PF=0.866 0.26 % 0.28 % 0.33 %
Ø 40°
PF=0.766 0.37 % 0.39 % 0.42 %
Ø 50°
PF=0.643 0.53 % 0.56 %
Ø 60°
PF=0.500 0.76 % 0.77 % 0.78 %
Ø 70°
PF=0.342 1.2 % | ||
| 21 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 21 of 38
Parameter/Range
Frequency
CMC2, 4, 5 (±)
Comments
AC Power – Generate3
See Table below
See Table below
Fluke 5560A
(65 to 500) Hz (33.66 to 336.6)
W
(0.3366 to
1.122) kW
(1.122 to 3.06)
kW
(3.06 to 11.22)
kW
(11.22 to 20.9)
kW
Ø 80°
PF=0.174 2.5 %
500 Hz to 1
kHz
(33.66 to 336.6)
W
(0.3366 to
1.122) kW
(1.122 to
3.06) kW
(3.06 to 11.22)
kW
(11.22 to 20.9)
kW
Ø 0°
PF=1.000 0.052 % 0.068 % 0.076 % 0.12 % 0.21 %
(45 to 65) Hz (1.22 to
12.2) W
(12.2 to
122) W
(0.122 to
1.22) kW
(1.22 to 3.16)
kW
(3.16 to
12.2) kW
(12.2 to
30.8) kW
Ø 0°
PF=1.000 0.038 % 0.029 % 0.034 % 0.048 % 0.04 % 0.11 %
Ø 10°
PF=0.985 0.049 % 0.042 % 0.046 % 0.057 % 0.051 % 0.11 %
Ø 20°
PF=0.940 0.074 % 0.07 % 0.072 % 0.079 % 0.075 % 0.12 %
Ø 30°
PF=0.866 0.11 % 0.15 %
Ø 40°
PF=0.766 0.15 %
Ø 50°
PF=0.643 0.21 %
Ø 60°
PF=0.500 0.3 %
Ø 70°
PF=0.342 0.48 %
Ø 80°
PF=0.174 0.99 %
(65 to 500) Hz (12.2 to 122)
W
(0.122 to 1.22)
kW
(1.22 to 3.16)
kW
(3.16 to 12.2)
kW
(12.2 to 30.8)
kW
Ø 0°
PF=1.000 0.029 % 0.034 % 0.048 % 0.04 % 0.11 %
Ø 10°
PF=0.985 0.068 % 0.071 % 0.078 % 0.074 % 0.12 %
Ø 20°
PF=0.940 0.14 % 0.17 %
Ø 30°
PF=0.866 0.2 % 0.21 % 0.23 %
Ø 40°
PF=0.766 0.29 % 0.3 % 0.31 %
Ø 50°
PF=0.643 0.42 % | ||
| 22 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 22 of 38
Parameter/Range
Frequency
CMC2, 4, 5 (±)
Comments
AC Power – Generate3
(cont)
See Table below
See Table below
Fluke 5560A
(65 to 500) Hz (12.2 to 122)
W
(0.122 to
1.22) kW (1.22 to 3.16) kW (3.16 to 12.2)
kW
(12.2 to 30.8)
kW
Ø 60°
PF=0.500 0.61 %
Ø 70°
PF=0.342 0.96 %
Ø 80°
PF=0.174 2 %
500 Hz to 1
kHz
(12.2 to 122)
W
(0.122 to
1.22) kW (1.22 to 3.16) kW (3.16 to 12.2)
kW
(12.2 to 30.8)
kW
Ø 0°
PF=1.000 0.029 % 0.034 % 0.048 % 0.04 % 0.11 %
Ø 10°
PF=0.985 0.13 % 0.16 %
Ø 20°
PF=0.940 0.26% 0.28 %
Ø 30°
PF=0.866 0.41% 0.42 %
Ø 40°
PF=0.766 0.59 % 0.6 %
Ø 50°
PF=0.643 0.83 %
Ø 60°
PF=0.500 1.2 %
Ø 70°
PF=0.342 1.9 %
Ø 80°
PF=0.174 4 %
(1 to 5) kHz (6 to 60) W (60 to 600) W (0.6 to 1.55) kW
Ø 0°
PF=1.000 0.071 % 0.082 %
Ø 10°
PF=0.985 0.64 %
Ø 20°
PF=0.940 1.3 %
Ø 30°
PF=0.866 2 %
Ø 40°
PF=0.766 2.8 %
Ø 50°
PF=0.643 4 % | ||
| 23 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 23 of 38
Parameter/Range
Frequency
CMC2, 4, 5 (±)
Comments
AC Power – Generate3
(cont)
See Table below
See Table below
Fluke 5560A
(5 to 10) kHz (3 to 30) W (30 to 300) W
Ø 0°
PF=1.000 0.28 % 0.34 %
Ø 10°
PF=0.985 1.4 %
(5 to 10) kHz (3 to 30) W (30 to 300) W
Ø 20°
PF=0.940 2.7 %
Ø 30°
PF=0.866 4.2 %
(10 to 30) kHz (3 to 300) W
Ø 0°
PF=1.000 1.1 %
Ø 10°
PF=0.985 3.4 %
Ø 20°
PF=0.940 5.9%
Phase3 (PF=1) –
Generate
(10 to 65) Hz
(65 to 500) Hz
500 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(3 to 65) Hz
(65 to 500) Hz
500 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
Ø 0.1°
Ø 0.26°
Ø 0.51°
Ø 2.6°
Ø 5.1°
Ø 10°
Ø 0.1°
Ø 0.2°
Ø 0.4°
Ø 1.9°
Ø 3.9°
Ø 7.8°
Fluke 5520A
Fluke 5560A
Capacitance3 – Generate
(0.19 to 0.3999) nF
(0.4 to 1.0999) nF
(1.1 to 3.2999) nF
(3.3 to 10.9999) nF
(11 to 32.9999) nF
(33 to 109.999) nF
(110 to 329.999) nF
10 Hz to 10 kHz
10 Hz to 10 kHz
10 Hz to 3 kHz
10 Hz to 1 kHz
10 Hz to 1 kHz
10 Hz to 1 kHz
10 Hz to 1 kHz
8.8 pF + 4 pF/nF
9.7 pF + 4 pF/nF
13 pF + 4 pF/nF
15 pF + 2 pF/nF
0.1 nF + 2 pF/nF
0.15 nF + 2 pF/nF
0.46 nF + 2 pF/nF
Fluke 5520A | ||
| 24 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 24 of 38
Parameter/Range
Frequency
CMC2, 4, 5 (±)
Comments
Capacitance3 – Generate
(cont)
(0.33 to 1.0999) µF
(1.1 to 3.299 99) µF
(3.3 to 10.9999) µF
(11 to 32.9999) µF
(33 to 109.999) µF
(110 to 329.999) µF
(0.33 to 1.099 99) mF
(1.1 to 3.2999) mF
(3.3 to 10.9999) mF
(11 to 32.9999) mF
(33 to 110) mF
200 pF to 1.2 nF
(1.2 to 12) nF
(> 3 to 12) nF
(12 to 120) nF
(> 30 to 120) nF
(0.12 to 1.2) µF
(1.2 to 12) µF
(12 to 120) µF
(0.12 to 1.2) mF
(1.2 to 12) mF
(12 to 120) mF
(10 to 600) Hz
(10 to 300) Hz
(10 to 150) Hz
(10 to 120) Hz
(10 to 80) Hz
(10 to 50) Hz
(10 to 20) Hz
(0 to 6) Hz
(0 to 2) Hz
(0 to 0.6) Hz
(0 to 0.2) Hz
100 Hz to 10 kHz
150 Hz to 5 kHz
(10 to 150) Hz
200 Hz to 1.3 kHz
(10 to 200) Hz
(2 to 310) Hz
(0.5 to 110) Hz
(0.5 to 40) Hz
(0.1 to 11) Hz
(0.03 to 4) Hz
(0.01 to 1.3) Hz
1.5 nF + 2 nF/µF
4.6 nF + 2 nF/µF
15 nF + 2 nF/µF
59 nF + 3.2 nF/µF
0.2 µF + 3.6 nF/µF
0.64 µF + 3.6 nF/µF
2 µF + 3.6 µF/mF
7 µF + 3.5 µF/mF
38 µF + 2.6 µF/mF
90 µF + 6 µF/mF
0.37 mF + 8.8 µF/mF
2.4 pF + 0.86 mF/F
6.2 pF + 0.9 mF/F
7.8 pF + 0.9 mF/F
43 pF + 1 mF/F
61 pF + 1 mF/F
0.42 nF + 1 mF/F
4.2 nF + 1 mF/F
40 nF + 1.2 mF/F
0.48 µF + 1.9 mF/F
5.3 µF + 1.9 mF/F
77 µF + 3.9 mF/F
Fluke 5520A
Fluke 5560A
Capacitance – Measure
1 pF
10 pF
100 pF
1 nF
10 nF
100 nF
50 Hz to 1 kHz
(1 to 100) kHz
(50 to 300) Hz
300 Hz to 10 kHz
(10 to 20) kHz
(20 to 100) kHz
(50 to 100) Hz
100 Hz to 1 kHz
(1 to 20) kHz
(20 to 100) kHz
(50 to 300) Hz
300 Hz to 20 kHz
(20 to 100) kHz
50 Hz to 20 kHz
(20 to 100) kHz
50 Hz to 20 kHz
(20 to 100) kHz
12 %
1.2 %
12 %
1.2 %
0.13 %
0.47 %
12 %
1.2 %
0.13 %
0.47 %
1.2 %
0.13 %
0.47 %
0.13 %
0.47 %
0.13 %
0.47 %
Fluke PM6304 | to 120 mF |
| 25 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 25 of 38
Parameter/Range
Frequency
CMC2, 4, 5 (±)
Comments
Capacitance – Measure
(cont)
1 µF
10 µF
100 µF
50 Hz to 20 kHz
(20 to 100) kHz
50 Hz to 20 kHz
(20 to 100) kHz
50 Hz to 10 kHz
(10 to 20) kHz
(20 to 100) kHz
0.13 %
0.47 %
0.13 %
1.2 %
0.13 %
1.2 %
12 %
Fluke PM6304
Capacitance – Generate,
Fixed Points3
1 pF
10 pF
100 pF
1000 pF
1 kHz
1 MHz
2 MHz
3 MHz
4 MHz
5 MHz
10 MHz
13 MHz
1 kHz
1 MHz
2 MHz
3 MHz
4 MHz
5 MHz
10 MHz
13 MHz
1 kHz
1 MHz
2 MHz
3 MHz
4 MHz
5 MHz
10 MHz
13 MHz
1 kHz
1 MHz
2 MHz
3 MHz
4 MHz
5 MHz
10 MHz
13 MHz
0.000 05 pF
0.000 09 pF
0.000 23 pF
0.000 41 pF
0.000 63 pF
0.0009 pF
0.0025 pF
0.0037 pF
0.0001 pF
0.000 41 pF
0.000 42 pF
0.0004 pF
0.0005 pF
0.0006 pF
0.0012 pF
0.0016 pF
0.001 pF
0.004 pF
0.005 pF
0.0067 pF
0.009 pF
0.013 pF
0.033 pF
0.049 pF
0.043 pF
0.065 pF
0.15 pF
0.28 pF
0.44 pF
0.62 pF
1.9 pF
2.8 pF
Agilent 16380A
capacitance set | ||
| 26 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 26 of 38
Parameter/Range
Frequency
CMC2, 4, 5 (±)
Comments
Capacitance – Generate,
Fixed Points3 (cont)
10 nF
100 nF
1 µF
120 Hz to 100 kHz
120 Hz to 200 kHz
120 Hz
> 120 Hz to 10 kHz
(> 10 to 100) kHz
0.51 pF
5.1 pF
65 pF
57 pF
81 pF
Agilent 16380C
capacitance set
AC Flatness3 – Measure
10 Hz
100 Hz to 100 kHz
500 kHz
1 MHz
(3 to 8) MHz
10 MHz
15 MHz
20 MHz
26 MHz
30 MHz
0.2 %
0.069 %
0.11 %
0.11 %
0.21 %
0.21 %
0.21 %
0.23 %
0.36 %
0.55 %
EL1100 3V TVC
Inductance – Generate &
Measure3, 4
100 µH
1 mH
10 mH
100 mH
1 H
10 H
100 Hz to 2 kHz
5 kHz
10 kHz
20 kHz
100 kHz
(100 to 200) Hz
500 Hz to 20 kHz
100 kHz
100 Hz
200 Hz to 20 kHz
100 Hz to 10 kHz
20 kHz
100 Hz to 5 kHz
100 Hz to 1 kHz
2 kHz
1.2 %
0.13 %
0.14 %
0.19 %
0.47 %
1.2 %
0.12 %
0.46 %
1.2 %
0.12 %
0.14 %
0.4 %
0.12 %
0.12 %
0.22 %
General Radio 1491-
G & Fluke PM6304 | ||
| 27 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 27 of 38
Parameter/Range
Frequency
CMC2, 4, 5 (±)
Comments
Inductance – Generate3
(13 to 120) µH
(0.120 01 to 1.2) mH
(1.2001 to 3.3) mH
(3.3 to 12) mH
(12 to 83) mH
(83 to 120) mH
(0.120 01 to 0.65) H
(0.65 to 1.2) H
(1.2001 to 5.5) H
(490 to 550) Hz
(550 to 999) Hz
1 kHz
(1.001 to 13) kHz
(13 to 17) kHz
(260 to 330) Hz
(330 to 999) Hz
1 kHz
(1.001 to 1.6) kHz
(1.6 to 2.5) kHz
(0.5 to 999) Hz
110 Hz
(111 to 800) Hz
(800 to 980) Hz
(0.5 to 109) Hz
110 Hz
(111 to 1000) Hz
(1 to 1.4) kHz
(0.1 to 99) Hz
100 Hz
(101 to 180) Hz
(180 to 230) Hz
(0.1 to 99) Hz
100 Hz
(101 to 320) Hz
(320 to 1000) Hz
(0.05 to 9.9) Hz
10 Hz
(10.1 to 30) Hz
(30 to 50) Hz
(0.05 to 9.9) Hz
10 Hz
(10.1 to 100) Hz
(100 to 170) Hz
(0.01 to 2.99) Hz
3 Hz
(3.01 to 8) Hz
(8 to 16) Hz
1.5 %
0.67 %
0.38 %
0.67 %
1.5 %
1.4 %
0.49 %
0.2 %
0.49 %
1.4 %
0.74 %
0.46 %
0.74 %
1.6 %
0.49 %
0.2 %
0.49 %
1.4 %
0.53 %
0.25 %
0.53 %
1.4 %
0.49 %
0.2 %
0.49 %
1.4 %
0.61 %
0.32 %
0.6 %
1.5 %
0.52 %
0.24 %
0.52 %
1.4 %
0.68 %
0.4 %
0.68 %
1.6 %
Fluke 5560A | ||
| 28 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 28 of 38
Parameter/Range
Frequency
CMC2, 4, 5 (±)
Comments
Inductance – Generate3
(cont)
(5.5 to 12) H
(12.001 to 30) H
(30 to 120) H
(0.01 to 2.99) Hz
3 Hz
(3.01 to 19) Hz
(19 to 37) Hz
(0.005 to 1.99) Hz
2 Hz
(2.01 to 4) Hz
(4 to 16) Hz
(0.005 to 1.99) Hz
2 Hz
(2.01 to 7) Hz
(7 to 14) Hz
0.57 %
0.28 %
0.57 %
1.4 %
0.89 %
0.61 %
0.89 %
1.8 %
0.61 %
0.32 %
0.6 %
1.5 %
Fluke 5560A
Phase – Measure
Up to 360°
(10 to 32) mV
32 mV to 100 V
(100 to 320) V
(10 to 32) mV
32 mV to 100 V
(10 to 100) mV
100 mV to 100 V
(10 to 100) mV
100 mV to 100 V
(10 to 100) mV
100 mV to 100 V
10 Hz to 5 kHz
(5 to 10) kHz
(10 to 40) kHz
(40 to 50) kHz
(50 to 100) kHz
0.23°
0.059°
0.12°
0.23°
0.059°
0.41°
0.061°
0.41°
0.071°
0.41°
0.41°
Krohn-Hite 6620A
Distortion – Measure3, 6
20 Hz to 20 kHz
(20 to 100) kHz
100 kHz to 2.9 GHz
(2.9 to 6.5) GHz
(6.5 to 13.2) GHz
(13.2 to 50) GHz
1.2 dB
2.3 dB
2.4 dB
3.1 dB
3.6 dB
4.8 dB
Agilent 8903A
Keysight 8568EC | to 360 ° |
| 29 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 29 of 38
Parameter/Range
Frequency
CMC2, 4, 5 (±)
Comments
Oscilloscopes3 –
Amplitude – DC Signal:
50 Ω Load
1 MΩ Load
Amplitude – Squarewave:
50 Ω Load
1 MΩ Load
Edge into 50 Ω
Bandwidth
Time Markers
(-6.6 to 6.6) V
(-130 to 130) V
1 mV to 6.6 Vp-p
1 mV to 130 Vp-p
10 Hz to 1 kHz
1 mV to 130 Vp-p
(1 to 100) kHz
≤ 300 ps (up to 2 MHz)
≤ 350 ps (above 2 MHz)
50 kHz ref
50 kHz to 100 MHz
(100 to 300) MHz
(300 to 600) MHz
(600 to 1100) MHz
5 s to 50 ms
20 ms to 1 ns
33 µV + 2 mV/V
33 µV + 0.39 mV/V
91 µV + 4.3 mV/V
0.2 mV + 0.8 mV/V
0.24 mV + 2 mV/V
82 ps
82 ps
0.33 mV + 1.7 mV/V
0.4 mV + 31 mV/V
0.43 mV + 36 mV/V
0.53 mV + 57 mV/V
0.58 mV + 67 mV/V
0.0021 % + (T/1000) %
0.000 36 %
Fluke 5520A
with SC1100
T = time in
seconds
IV. Electrical – RF/Microwave
Parameter/Equipment
Range CMC2, 4, 5 (±) Comments
Power Meter3
Power Reference @ 1 mW
Power Accuracy
50 MHz
3 µW to 100 mW
0.45 %
0.29 %
Agilent 432A,
478A-H55, Agilent
3458A
Range calibrator | to 130 V |
| 30 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 30 of 38
Parameter/Equipment
Range CMC2, 4, 5 (±) Comments
Relative Power3 – Measure
(0 to -10) dB
(-10 to -20) dB
(-20 to -30) dB
(-30 to -40) dB
(-40 to -50) dB
(-50 to -60) dB
(-60 to -70) dB
(-70 to -80) dB
(-80 to -90) dB
(-90 to -100) dB
(-100 to -110) dB
(-110 to -120) dB
(-120 to -127) dB
(0 to -10) dB
(-10 to -20) dB
(-20 to -30) dB
(-30 to -40) dB
(-40 to -50) dB
(-50 to -60) dB
(-60 to -70) dB
(-70 to -80) dB
(-80 to -90) dB
(-90 to -100) dB
(-100 to -110) dB
(-110 to -120) dB
(-120 to -127) dB
2.5 MHz to 1.3 GHz
(1.3 to 26.5) GHz
0.047 dB
0.06 dB
0.074 dB
0.087 dB
0.1 dB
0.1 dB
0.11 dB
0.12 dB
0.13 dB
0.15 dB
0.15 dB
0.28 dB
0.29 dB
0.066 dB
0.06 dB
0.074 dB
0.087 dB
0.1 dB
0.1 dB
0.11 dB
0.12 dB
0.13 dB
0.15 dB
0.15 dB
0.28 dB
0.29 dB
8902A
Absolute Power3 – Measure
(0 to +20) dBm
(-10 to 0) dBm
(-60 to -10) dBm
(+10 to +20) dBm
9 kHz to 16 GHz
(16 to 18) GHz
9 kHz to 16 GHz
(16 to 18) GHz
9 kHz to 2 GHz
(2 to 16) GHz
(16 to 18) GHz
100 kHz to 4.2 GHz
(4.2 to 18) GHz
(18 to 26.5) GHz
2.6 %
2.8 %
3.1 %
3.3 %
3.6 %
3.7 %
3.8 %
3.6 %
3.7 %
4.7 %
Agilent E4418B:
Agilent E9304A
Agilent 8482A
Agilent 8481A
Agilent 8485A | ||
| 31 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 31 of 38
Parameter/Range
Frequency CMC2, 4, 5 (±) Comments
Absolute Power3 –
Measure (cont)
(-30 to +10) dBm
100 kHz to 4.2 GHz
(4.2 to 18) GHz
(18 to 26.5) GHz
1.1 %
1.3 %
3.2 %
Agilent 8482A
Agilent 8481A
Agilent 8485A
Amplitude Modulation3 –
Measure
Rate: 50 Hz to 10 kHz
Depths: (5 to 99) %
Rate: 20 Hz to 10 kHz
Depths: to 99 %
Rate: 50 Hz to 50 kHz
Depths: (5 to 99) %
Rate: 20 Hz to 100 kHz
Depths: to 99 %
Rate: 50 Hz to 50 kHz
Depths: (5 to 99) %
Rate: 20 Hz to 100 kHz
Depths: to 99 %
150 kHz to 10 MHz
150 kHz to 10 MHz
(0.01 to 1.3) GHz
(0.01 to 1.3) GHz
(1.3 to 26.5) GHz
(1.3 to 26.5) GHz
0.14 % depth + 0.024 %
depth/% depth
0.11 % depth + 0.023 %
depth/% depth
0.15 % depth + 0.01 %
depth/% depth
0.11 % depth + 0.023 %
depth/% depth
0.33 % depth + 0.008 %
depth/% depth
0.31 % depth + 0.021 %
depth/% depth
8902A
Frequency Modulation3 –
Measure
Rate: 20 Hz to 10 kHz
Dev.: ≤ 40 kHz Peak
Rate: 50 Hz to 100 kHz
Dev.: ≤ 400 kHz Peak
Rate: 20 Hz to 200 kHz
Dev.: ≤ 400 kHz Peak
Rate: 50 Hz to 100 kHz
Dev.: ≤ 400 kHz Peak
Rate: 20 Hz to 200 kHz
Dev.: ≤ 400 kHz Peak
250 kHz to 10 MHz
(0.01 to 1.3) GHz
(0.01 to 1.3) GHz
(1.3 to 26.5) GHz
(1.3 to 26.5) GHz
3.5 Hz + 16 Hz/kHz
3.5 Hz + 7.8 Hz/kHz
6.8 Hz + 39 Hz/kHz
6.8 Hz + 7.8 Hz/kHz
6.8 Hz + 39 Hz/kHz
8902A | -30 to 10 dBm |
| 32 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 32 of 38
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
Phase Modulation3 –
Measure
Rate: 200 Hz to 10 kHz
(0 to 100) rad
Rate: 200 Hz to 20 kHz
(0 to 100) rad
Rate: 200 Hz to 20 kHz
(0 to 100) rad
150 kHz to 10MHz
(0.01 to 1.3) GHz
(1.3 to 26.5) GHz
36 mrad + 37 mrad/rad
36 mrad + 37 mrad/rad
36 mrad + 37 mrad/rad
8902A
V. Mechanical
Parameter/Equipment
Range CMC2, 5, 8 (±) Comments
Accelerometers6 –
Amplitude Response
(mV/g Sensitivity) @
Test Levels From
(1 to 10) g
(0.5 to < 1) Hz
(1 to < 100) Hz
100 Hz
> 100 Hz to 1 kHz
(> 1 to 5) kHz
(> 5 to 10) kHz
1.8 %
1 %
0.8 %
1 %
1.4 %
1.9 %
VR9500, Reference
Accelerometer
Mass6 – Measure
Class 2 or Higher
1 mg to 5 g
10 g
20 g
30 g
50 g
100 g
200 g
300 g
500 g
13 µg
15 µg
19 µg
28 µg
29 µg
51 µg
110 µg
1.1 mg
1.2 mg
Mass comparator,
Class 1 weights
(ABBA method)
Mass – Direct Weigh
Up to 50 g
(50 to 100) g
(100 to 205) g
Up to 620 g
Up to 6 kg
42 µg
61 µg
120 µg
2.9 mg
29 mg
Electronic balances | ||
| 33 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 33 of 38
Parameter/Equipment
Range CMC2, 5, 8 (±) Comments
Balances3, 6
0.0001 g Resolution
0.001 g Resolution
0.01 g Resolution
0.1 g & 1 g Resolution
Up to 500 mg
> 500 mg to 5 g
> 5 g to 15 kg
Up to 50 g
(> 50 to 100) g
(> 100 to 300) g
> 300 g to 15 kg
Up to 500 g
Up to 15 kg
0.82 x R
0.91 x R
1.2 x R
0.83 x R
0.87 x R
1.0 x R
1.2 x R
0.83 x R
1.4 x R
Class 1, Class 6 weights
Scales3, 6
Up to 2000 lb
0.82 x R
Class 6 weights
Force Measuring
Equipment3, 6 – Tension &
Compression
Up to 500 lb
0.0023 %
Class F weights
Cable Tensiometers6
Up to 250 lbf
(250 to 600) lbf
0.45 %
0.42 %
CDI torque calibration
system, tension cables
Pressure – Precision
Measuring Equipment6
Pneumatic3
(0.2 to 25) psia
(25 to 1000) psia
(0.2 to 25) psig
(25 to 1000) psig
(0.6 to 50) pisg
(1.3 to 55) psia
(1.5 to 250) psig
(3.6 to 275) psia
(6 to 1000) psig
(14.5 to 1100) psia
(8 to 17) psia
(-15 to 15) psig
0.0049 %
0.0057 %
0.0014 %
0.0031 %
0.0012 %
0.0012 %
0.0014 %
0.0014 %
0.002 %
0.002 %
0.01 %
0.003 psi
Ruska 2465 gas piston
gauge
Fluke PG7601 with
AMH-38
Mensor CPC6050
w/ sensor range:
(8 to 17) psia module
(-15 to +15) psig module | ||
| 34 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 34 of 38
Parameter/Equipment
Range CMC2, 5, 8 (±) Comments
Pressure – Precision
Measuring Equipment6
(cont)
Pneumatic3
(-15 to 50) psig
(> 50 to 150) psig
(-15 to 100) psig
(> 100 to 300) psig
(-15 to 330) psig
(> 300 to 1000) psig
(4 to 854) in∙H
2O
0.0044 psi
0.008 %
0.0083 psi
0.008 %
0.027 psi
0.008 %
0.0087 %
Mensor CPC6050
w/ sensor range:
(-15 to 150) psig module
(-15 to 300) psig module
(-15 to 1000) psig module
Ametek PK-854WC-SS
Pressure – Precision
Measuring Equipment3, 6
Pneumatic
(0 to 0.25) inH2O
(0 to 0.5) inH2O
Up to ± 1 inH2O
(0 to 16) inH2O
(-8 to 8) inH2O
(-80 to 80) inH2O
± (0 to 25) inH2O
(-100 to -25) inH2O
(25 to 100) inH2O
(-15 to 30) psi
(0.1 to 10) in∙H2O
(14.5 to 1160) psig
(29 to 1174) psia
(72.5 to 5800) psig
(87 to 5814.5) psia
0.000 24 inH
2O
0.000 41 inH2O
0.0014 inH2O
0.011 inH2O
0.000 045 inH2O +
0.0012 inH2O/inH2O
0.000 41 inH2O +
0.0012 inH2O/inH2O
0.0014 inH
2O + 0.000
047 inH2O/inH2O
0.011 %
0.028 psi
0.034 in∙H2O
0.00067 psi + 0.002 %
0.002 psi + 0.002 %
0.0025 psi + 0.002 %
0.0035 psi + 0.002 %
AQS-1 modules w/digital
display
Furnace Control PPC500
Fluke 7250LP
Fluke 700PD7
Fluke 700P01
DHI PG7202 with:
PC7200-100 piston
PC7200-500 piston | ||
| 35 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 35 of 38
Parameter/Equipment
Range CMC2, 5, 8 (±) Comments
Pressure – Precision
Measuring Equipment3, 6
(cont)
Hydraulic
(250 to 16 000) psig
(304.5 to 16 014.5) psia
(1 to 1000) psi
(10 to 15 000) psi
0.016 psi + 0.0045 %
0.019 psi + 0.0045 %
0.0092 %
0.016 %
DHI PG7202 with:
PC7200-2 piston
Ametek HK-1000
Ametek WG-15Q-1L
Torque Tools3, 6
15 ozf·in to 2000 lbf·ft
0.31 %
CDI torque
calibration system
Torque Transducers3, 6
5 ozf·in to 10 lbf·in
10 lbf·in to 250 lbf·ft
(250 to 2000) lbf·ft
0.039 %
0.036 %
0.034 %
Torque arms, Class 6
weights
IV. Photometry
Parameter/Equipment
Range
CMC2, 5, 8 (±)
Comments
Illuminance –
Measuring Equipment
(5 to 5200) Lux
1.6 %
Meter-to-meter
comparison using
Konica Minolta
CL200A, lamp
Luminance –
Measuring Equipment
(0.5 to 1700) fL
1.8 %
Hoffman
Engineering LS-65-
8C | ||
| 36 | AMS 2750 | - | See scope document |
| 37 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 37 of 38
VI. Time & Frequency
Parameter/Equipment
Range
CMC2, 8 (±)
Comments
Frequency – Measuring
Equipment3
0.01 Hz to 20 MHz
20 MHz to 20 GHz
0.58 µHz
0.58 mHz + 73 nHz/Hz
Agilent 33220A &
E8257D, GPS
receiver
Frequency – Measure3
0.1 Hz to 12.4 GHz
73 nHz + 12 pHz/Hz
HP 53132A, GPS
receiver
Stopwatches & Timers3
± (0 to 19.99) sec/day
37 ms/day
Timometer
Tachometers3
(1 to 100 000) rpm
0.000 35 rpm + 0.000
038 rpm/rpm
Fluke 5520A
______________________
1 This laboratory offers commercial calibration services and field calibration services.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC uncertainty found
on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of
calibration and for other possible adverse effects such as those caused by transportation of the calibration
equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g.,
resolution) must also be considered and this, on its own, could result in the actual measurement
uncertainty achievable on a customer’s site being larger than the CMC uncertainty.
4 The stated measured values are determined using the indicated instrument (see Comments). This capability
is suitable for the calibration of the devices intended to measure or generate the measured value in the
ranges indicated. CMC’s are expressed as eith er a specific value that covers the full range or as a
percentage or fraction of the reading plus a fixed floor specification.
5 In the statement of CMC, R is the resolution of the unit under test; all percentages are percent of reading
unless otherwise indicated.
6 Uncertainty components that can be reasonably attributed to the Unit Under Test have not been utilized
in the calculation of the CMC value for this measurement parameter.
7 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 38 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 38 of 38
8 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
9 The contributions from the resolution of the device under calibration are not included in the CMC claim. | ||
| 39 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ANSI/NCSL Z540.3-2006; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Applied Technical ServicesGreer, SC · ~138 kmA2LAShares 2 accredited methods and materialsANSI/NCSL Z540-1-1994pH buffer solutions
- MSI-Viking Gage, LLC.Greer, SC · ~138 kmA2LAShares 2 accredited methods and materialsANSI/NCSL Z540-1-1994pH buffer solutions
- All American Scales & CalibrationParis, OH · ~592 kmA2LAShares 2 accredited methods and materialsANSI/NCSL Z540-1-1994pH buffer solutions
- Applied Technical Services , LLC.Sanford, FL · ~745 kmA2LAShares 2 accredited methods and materialsANSI/NCSL Z540-1-1994pH buffer solutions
- Empire Scale Corporation d.b.a Precision Scale & BalanceLancaster, NY · ~848 kmA2LAShares 2 accredited methods and materialsANSI/NCSL Z540-1-1994pH buffer solutions
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.