Trescal, Inc. - Charlotte, NC

10442 BAILEY ROAD, SUITE B, 28031, Cornelius, NC, United States

Visit website
A2LA 1877.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
39
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 39 scope lines.

A2LA certificate 1877.01 · 39 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ANSI/NCSL Z540.3-2006pH buffer solutions0 to 60 °
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 2 of 38 Parameter/Equipment Range CMC2 (±) Comments Depth Gages3, 9 Up to 40 in 13 µin + 5.1 µin/in Gage blocks Indicators3, 9 Up to 2 in 17 µin + 2.3 µin/in Gage blocks Height Gages3, 9 Up to 40 in 13 µin + 5.4 µin/in Gage blocks Calipers3, 9 – Outside Step/Depth Inside Up to 40 in Up to 40 in Up to 1 in 12 µin + 5.1 µin/in 13 µin + 5.1 µin/in 44 µin Gage blocks Gage blocks, accessories Micrometers3, 9 – Linearity Flatness Up to 40 in 50 µin 8.7 µin + 5.2 µin/in 5.5 µin Gage blocks Optical flat Tape Measure & Steel Ruler3, 9 Up to 39 in 36 in to 100 ft 0.0023 in 0.0023 in + 11 µin/in Rigid ruler, gage blocks, jeweler’s loupe; no tension applied. III. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 4 (±) Comments DC Voltage3, 6 – Generate Up to 220 mV (0.22 to 2.2) V (2.2 to 11) V (11 to 22) V (22 to 220) V (220 to 1100) V 0.49 µV + 5.7 nV/mV 0.8 µV + 3.5 µV/V 2.9 µV + 2.5 µV/V 4.3 µV + 2.5 µV/V 43 µV + 3.5 µV/V 0.42 mV + 4.5 µV/V Fluke 5720A
to 40 in
3--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 3 of 38 Parameter/Equipment Range CMC2, 4, 5 (±) Comments DC Voltage3, 6 – Generate (cont) (0 to 120) mV (0 to 1.2) V (0 to 12) V (0 to 120) V (0 to 1020) V 0.8 µV + 9.3 µV/V 1.9 µV + 5.8 µV/V 10 µV + 6.2 µV/V 0.1 mV + 8.5 µV/V 1 mV + 8.5 µV/V Fluke 5560A DC Voltage3 – Measure Up to 200 mV 200 mV to 2 V (2 to 20) V (20 to 200) V (200 to 1000) V 0.11 µV + 5 pV/mV 5.1 µV + 3.6 µV/V 5.3 µV + 3.4 µV/V 0.86 mV + 2.8 µV/V 0.93 mV + 5.1 µV/V Fluke 8508A DC High Voltage3 – Measure (1 to 10) kV (10 to 70) kV 3.2 V + 0.17 V/kV 8.7 V + 0.45 V/kV Vitrek 4700 HV meter with Vitrek HVL-70 probe. DC Current3, 6 – Generate Clamp Meters 3 Up to 220 µA (0.22 to 2.2) mA (2.2 to 22) mA (22 to 220) mA (0.22 to 2.2) A (2.2 to 11) A (11 to 20.5) A (0 to 120) µA (0 to 1.2) mA (0 to 12) mA (0 to 120) mA (0 to 1.2) A (0 to 3.1) A (0 to 12) A (0 to 30.2) A (10 to 16.5) A (16.5 to 150) A (150 to 1025) A (1000 to 5000) A 6 nA + 35 pA/µA 7.1 nA + 30 nA/mA 41 nA + 30 nA/mA 0.73 µA + 50 nA/mA 12 µA + 0.11 mA/A 0.49 mA + 0.34 mA/A 9.4 mA + 0.8 mA/A 6 nA + 97 µA/A 15 nA + 78 µA/A 82 nA + 78 µA/A 0.82 µA + 78 µA/A 10 µA + 0.12 mA/A 0.15 mA + 0.23 mA/A 0.25 mA + 0.23 mA/A 0.5 mA + 0.78 mA/A 50 mA + 6.5 mA/A 0.18 A + 3.4 mA/A 0.83 A + 3.3 mA/A 1.2 A + 4.6 mA/A Fluke 5720A w/5725A Fluke 552XA Fluke 5560A Fluke 5212XA with 5500/coil Fluke 52120 with coil 6KA DC Current – Generate (1 to 100) nA 100 nA to 1 µA (1 to 10) µA 0.37 % 0.25 % 0.062 % 5720A, IET standard resistors
0 to 1020 V
4--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 4 of 38 Parameter/Equipment Range CMC2, 4, 5 (±) Comments DC Current3 – Measure Up to 200 µA 200 µA to 2 mA (2 to 20) mA (20 to 200) mA 200 mA to 2 A (2 to 20) A 2.4 nA + 6.4 pA/A 6 nA + 11 nA/A 32 nA + 14 nA/A 0.63 µA + 47 nA/A 14 µA + 0.18 mA/A 0.33 mA + 0.55 mA/A Fluke 8508A DC Power3 – Generate Up to 330 µA Up to 3.3 mA Up to 33 mA Up to 330 mA Up to 1.1 A Up to 3 A Up to 11 A Up to 20.5 A Up to 120 µA Up to 1.2 mA Up to 12 mA Up to 120 mA Up to 1.2 A Up to 3.1 A Up to 12 A Up to 30.2 A Up to 1020 V Up to 337 mW (0.337 to 3.366) W (3.366 to 33.66) W (33.66 to 336.6) W (0.3366 to 1.122) kW (1.122 to 3.06) kW (3.06 to 11.22) kW (11.22 to 20.91) kW Up to 122 mW (0.12 to 1.224) W (1.225 to 12.24) W (12.24 to 122.4) W (0.1224 to 1.224) kW (1.224 to 3.162) kW (3.162 to 12.24) kW (12.24 to 30.8) kW 0.017 % 0.021 % 0.0093 % 0.0093 % 0.019 % 0.043 % 0.044 % 0.13 % 0.015 % 0.0092 % 0.0087 % 0.0087 % 0.013 % 0.028 % 0.025 % 0.08 % Fluke 5520A Fluke 5560A DC Resistance3, 6 – Generate (0 to 10.9999) Ω (11 to 32.9999) Ω (33 to 109.9999) Ω (110 to 329.9999) Ω (330 to 1099.999) Ω (1.1 to 3.299 999) kΩ (3.3 to 10.999 99) kΩ (11 to 32.999 99) kΩ (33 to 109.9999) kΩ (110 to 329.9999) kΩ (330 to 1099.999) kΩ (1.1 to 3.299 999) MΩ (3.3 to 10.999 99) MΩ (11 to 32.999 99) MΩ (33 to 109.9999) MΩ (110 to 329.9999) MΩ (330 to 1100) MΩ 1.2 mΩ + 24 µΩ/Ω 1.5 mΩ + 24 µΩ/Ω 1.9 mΩ + 22 µΩ/Ω 4.1 mΩ + 22 µΩ/Ω 9.1 mΩ + 22 µΩ/Ω 41 mΩ + 22 µΩ/Ω 92 mΩ + 22 µΩ/Ω 0.41 Ω + 22 µΩ/Ω 0.9 Ω + 22 µΩ/Ω 8.4 Ω + 26 µΩ/Ω 14 Ω + 26 µΩ/Ω 93 Ω + 48 µΩ/Ω 0.4 kΩ + 0.1 mΩ/Ω 4.4 kΩ + 0.2 mΩ/Ω 16 kΩ + 0.4 mΩ/Ω 0.35 MΩ + 2.4 mΩ/Ω 4.4 MΩ + 12 mΩ/Ω Fluke 552XA
to 20.5 A
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 5 of 38 Parameter/Equipment Range CMC2, 4 (±) Comments DC Resistance3, 6 – Generate (cont) Calibration of High Voltage Megohm Meters Fixed Points (0 to 12) Ω (12 to 120) Ω 120 Ω to 1.2 kΩ (1.2 to 12) kΩ (12 to 120) kΩ 120 kΩ to 1.2 MΩ (1.2 to 12) MΩ (12 to 120) MΩ (120 to 1200) MΩ 1 Ω 1.8 Ω 3.7 Ω 5.9 Ω 10 Ω 18 Ω 37 Ω 59 Ω 100 Ω 180 Ω 370 Ω 590 Ω 1 kΩ 1.8 kΩ 3.7 kΩ 5.9 kΩ 18.24 GΩ (10 to 99.99) kΩ (100 to 999.9) kΩ (1 to 9.99) MΩ (10 to 99.99) MΩ (100 to 999.9) MΩ (1 to 10.05) GΩ 0 Ω 1 Ω 1.9 Ω 10 Ω 19 Ω 100 Ω 190 Ω 1 kΩ 1.9 kΩ 10 kΩ 19 kΩ 100 kΩ 190 kΩ 1 mΩ + 19 µΩ/Ω 1.2 mΩ + 19 µΩ/Ω 4.4 mΩ + 19 µΩ/Ω 44 mΩ + 19 µΩ/Ω 0.44 Ω + 19 µΩ/Ω 4.4 Ω + 19 µΩ/Ω 63 Ω + 27 µΩ/Ω 6.5 kΩ + 0.33 mΩ/Ω 0.47 MΩ + 3.1 mΩ/Ω 11 mΩ 15 mΩ 22 mΩ 30 mΩ 46 mΩ 78 mΩ 0.16 Ω 0.29 Ω 0.46 Ω 0.78 Ω 1.6 Ω 2.1 Ω 3.1 Ω 4.1 Ω 5.4 Ω 6.2 Ω 0.6 GΩ 22 Ω + 2.1 mΩ/Ω 0.22 kΩ + 2.1 mΩ/Ω 3.2 kΩ + 3.1 mΩ/Ω 52 kΩ + 5.2 mΩ/Ω 0.52 MΩ + 5.2 mΩ/Ω 10 MΩ + 10 mΩ/Ω 50 µΩ 95 µΩ 0.18 mΩ 0.26 mΩ 0.48 mΩ 1.1 mΩ 2 mΩ 9 mΩ 17 mΩ 90 mΩ 0.17 Ω 1.1 Ω 2.1 Ω Fluke 5560A Fluke 5080A/MEG Fluke 5720A
6--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 6 of 38 Parameter/Equipment Range CMC2, 4, 5 (±) Comments DC Resistance3, 6 – Generate (cont) Fixed Points 1 MΩ 1.9 MΩ 10 MΩ 19 MΩ 100 MΩ 18 Ω 36 Ω 0.37 kΩ 0.89 kΩ 10 kΩ Fluke 5720A DC Resistance3 – Generate, Fixed Points, High Voltage Up to 20 V Up to 100 V Up to 1000 V Up to 5000 V 1 kΩ 10 kΩ 100 kΩ 1 MΩ 10 MΩ 100 MΩ 1 GΩ 10 GΩ 100 GΩ 1 TΩ 10 MΩ 100 MΩ 1 GΩ 10 GΩ 100 GΩ 1 TΩ 0.0013 % 0.0013 % 0.0013 % 0.0022 % 0.004 % 0.012 % 0.062 % 0.24 % 0.36 % 0.51 % 0.54 % 0.5 % 0.5 % 0.5 % 0.51 % 0.51 % IET VRS-100-10- 1K-BP DC Resistance3 – Generate, Fixed Points to Calibrate Thermometer Digital Readouts 1 Ω 25 Ω 75 Ω 100 Ω 200 Ω 400 Ω 1 kΩ 10 kΩ 2.8 µΩ 23 µΩ 70 µΩ 96 µΩ 0.19 mΩ 0.37 mΩ 2.5 mΩ 31 mΩ Standard resistors
to 5000 V
7--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 7 of 38 Parameter/Equipment Range CMC2, 4, 5 (±) Comments Resistance3 – Measure Up to 2 Ω (2 to 20) Ω (20 to 200) Ω 200 Ω to 2 kΩ (2 to 20) kΩ (20 to 200) kΩ 200 kΩ to 2 MΩ (2 to 20) MΩ (20 to 200) MΩ 200 MΩ to 2 GΩ (2 to 20) GΩ 4.7 µΩ + 17 µΩ/Ω 48 µΩ + 7.9 µΩ/Ω 0.13 mΩ + 7.4 µΩ/Ω 0.47 mΩ + 7.8 µΩ/Ω 14 mΩ + 7.8 µΩ/Ω 4.7 mΩ + 7.8 µΩ/Ω 0.93 Ω + 10 µΩ/Ω 93 Ω + 21 µΩ/Ω 9.3 kΩ + 0.12 mΩ/Ω 0.93 MΩ + 1.4 mΩ/Ω 9.3 MΩ + 1.4 mΩ/Ω Fluke 8508A Resistance3 – Measure 333 µΩ 1 mΩ 10 mΩ 100 mΩ 1 Ω 10 Ω 100 Ω 1 kΩ 10 KΩ 0.0063 % 0.0066 % 0.0023 % 0.0031 % 0.0016 % 0.0016 % 0.0016 % 0.0016 % 0.0016 % Current transfer using standard shunt, Agilent 3458A Electrical Calibration of Thermocouple Indicators3 – Type B Type C Type E Type J (600 to 800) °C (800 to 1550) °C (1550 to 1820) °C (0 to 1000) °C (1000 to 1800) °C (1800 to 2000) °C (2000 to 2316) °C (-250 to -200) °C (-200 to -100) °C (-100 to 0) °C (0 to 600) °C (600 to 1000) °C (-210 to -100) °C (-100 to 800) °C (800 to 1200) °C 0.35 °C 0.28 °C 0.23 °C 0.16 °C 0.23 °C 0.27 °C 0.36 °C 0.25 °C 0.12 °C 0.091 °C 0.082 °C 0.1 °C 0.14 °C 0.091 °C 0.11 °C Fluke 7526A
to 2 Ω
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 8 of 38 Parameter/Equipment Range CMC2 (±) Comments Electrical Calibration of Thermocouple Indicators 3 – (cont) Type K Type L Type N Type R Type S Type T Type U (-250 to -200) °C (-200 to -100) °C (-100 to 500) °C (500 to 800) °C (800 to 1372) °C (-200 to -100) °C (-100 to 900) °C (-250 to -200) °C (-200 to -100) °C (-100 to 0) °C (0 to 100) °C (100 to 800) °C (800 to 1300) °C (50 to -25) °C (-25 to 0) °C (0 to 100) °C (100 to 400) °C (400 to 600) °C (600 to 1000) °C (1000 to 1600) °C (1600 to 1767) °C (-50 to -25) °C (-25 to 0) °C (0 to 100) °C (100 to 400) °C (400 to 600) °C (600 to 1000) °C (1000 to 1600) °C (1600 to 1767) °C (-250 to -200) °C (-200 to -100) °C (-100 to 0) °C (0 to 200) °C (200 to 400) °C (-200 to 0) °C (0 to 200) °C (200 to 600) °C 0.46 °C 0.16 °C 0.1 °C 0.1 °C 0.13 °C 0.1 °C 0.091 °C 0.73 °C 0.23 °C 0.12 °C 0.11 °C 0.1 °C 0.13 °C 0.55 °C 0.45 °C 0.39 °C 0.28 °C 0.22 °C 0.21 °C 0.2 °C 0.24 °C 0.51 °C 0.43 °C 0.38 °C 0.29 °C 0.23 °C 0.22 °C 0.22 °C 0.27 °C 0.35 °C 0.16 °C 0.14 °C 0.12 °C 0.12 °C 0.23 °C 0.1 °C 0.1 °C Fluke 7526A
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 9 of 38 Parameter/Equipment Range CMC2 (±) Comments Electrical Calibration of RTDs3 Indicating Systems – Pt 385, 100 Ω Pt 3926, 100 Ω Pt 3916, 100 Ω Pt 385, 200 Ω Pt 385, 500 Ω Pt 385, 1000 Ω Ni 120, 120 Ω Cu 427, 10 Ω (-200 to 80) °C (-80 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 800) °C (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (-200 to -190) °C (-190 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 630) °C (-200 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (-200 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (-80 to 260) °C (-100 to 260) °C 0.018 °C 0.023 °C 0.026 °C 0.029 °C 0.035 °C 0.042 °C 0.016 °C 0.018 °C 0.020 °C 0.024 °C 0.028 °C 0.035 °C 0.015 °C 0.016 °C 0.019 °C 0.019 °C 0.025 °C 0.028 °C 0.033 °C 0.037 °C 0.054 °C 0.057 °C 0.061 °C 0.061 °C 0.070 °C 0.072 °C 0.089 °C 0.028 °C 0.029 °C 0.036 °C 0.040 °C 0.047 °C 0.019 °C 0.020 °C 0.027 °C 0.028 °C 0.035 °C 0.010 °C 0.12 °C Fluke 7526A
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 10 of 38 Parameter/Equipment Range CMC2 (±) Comments Electrical Calibration of Thermocouple Indicators3 Type B Type C Type E Type J Type K Type N (250 to < 350) °C (350 to < 445) °C (445 to < 580) °C (580 to < 780) °C (750 to < 1000) °C (1000 to 1820) °C (0 to < 250) °C (250 to < 1000) °C (1000 to < 1500) °C (1500 to < 1800) °C (1800 to < 2000) °C (2000 to < 2250) °C (2250 to 2315) °C (-270 to < -245) °C (-245 to < -195) °C (-195 to < -155) °C (-155 to < -90) °C (-90 to < 15) °C (15 to < 890) °C (890 to 1000) °C (-210 to < -180) °C (180 to < -120) °C (-120 to < -50) °C (-50 to < 990) °C (990 to 1200) °C (-270 to < -255) °C (-255 to < -195) °C (-195 to < -115) °C (-115 to < -55) °C (-55 to < 1000) °C (1000 to 1372) °C (-270 to < -260) °C (-260 to < -200) °C (-200 to < -140) °C (-140 to < -70) °C (-70 to 25) °C (25 to < 160) °C (160 to 1300) °C 0.95 °C 0.74 °C 0.58 °C 0.46 °C 0.38 °C 0.3 °C 0.21 °C 0.17 °C 0.19 °C 0.22 °C 0.24 °C 0.3 °C 0.33 °C 1.2 °C 0.18 °C 0.1 °C 0.082 °C 0.073 °C 0.063 °C 0.07 °C 0.12 °C 0.1 °C 0.083 °C 0.073 °C 0.07 °C 2.2 °C 0.7 °C 0.12 °C 0.092 °C 0.073 °C 0.083 °C 5 °C 1 °C 0.23 °C 0.16 °C 0.13 °C 0.11 °C 0.1 °C Ectron 1140A
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 11 of 38 Parameter/Equipment Range CMC2 (±) Comments Electrical Calibration of Thermocouple Indicators3 – (cont) Type R Type S Type T (-50 to < -30) °C (-30 to < 45) °C (45 to < 160) °C (160 to < 380) °C (380 to < 775) °C (775 to 1768) °C (-50 to < -30) °C (-30 to < 45) °C (45 to < 105) °C (105 to < 310) °C (310 to < 615) °C (615 to 1768) °C (-270 to < -255) °C (-255 to < -240) °C (-240 to < -210) °C (-210 to < -150) °C (-150 to < -40) °C (-40 to < 100) °C (100 to 400) °C 0.65 °C 0.55 °C 0.41 °C 0.31 °C 0.27 °C 0.23 °C 0.62 °C 0.56 °C 0.41 °C 0.34 °C 0.3 °C 0.27 °C 1.8 °C 0.49 °C 0.3 °C 0.18 °C 0.12 °C 0.085 °C 0.08 °C Ectron 1140A Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage3, 6 – Generate Up to 2.2 mV (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz 4 µV + 0.33 µV/mV 4 µV + 85 nV/mV 4 µV + 75 nV/mV 4 µV + 0.18 µV/mV 5 µV + 0.46 µV/mV 10 µV + 0.9 µV/mV 20 µV + 1.2 µV/mV 20 µV + 2.5 µV/mV Fluke 5720A
12

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 12 of 38 Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage3, 6 – Generate (cont) (2.2 to 22) mV (22 to 220) mV 220 mV to 2.2 V (2.2 to 22) V (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz 4.5 µV + 0.22 µV/mV 4.2 µV + 85 nV/mV 4.2 µV + 75 nV/mV 4.4 µV + 0.18 µV/mV 6.1 µV + 0.46 µV/mV 12 µV + 0.9 µV/mV 23 µV + 1.2 µV/mV 26 µV + 2.5 µV/mV 17 µV + 0.22 µV/mV 9 µV + 85 nV/mV 8.7 µV + 75 nV/mV 11 µV + 0.18 µV/mV 16 µV + 0.46 µV/mV 31 µV + 0.9 µV/mV 48 µV + 1.2 µV/mV 78 µV + 2.5 µV/mV 90 µV + 0.22 mV/V 34 µV + 79 µV/V 18 µV + 39 µV/V 26 µV + 70 µV/V 54 µV + 0.11 mV/V 0.16 mV + 0.34 mV/V 0.56 mV + 0.83 mV/V 0.64 mV + 1.5 mV/V 0.89 mV + 0.22 mV/V 0.34 mV + 80 µV/V 0.15 mV + 40 µV/V 0.26 mV + 70 µV/V 0.41 mV + 0.1 mV/V 1.2 mV + 0.26 mV/V 4 mV + 0.9 mV/V 6.1 mV + 1.3 mV/V Fluke 5720A
13

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 13 of 38 Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage3, 6 – Generate (cont) (22 to 220) V* (220 to 750) V (220 to 1100) V (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (30 to 50) kHz (50 to 100) kHz 40 Hz to 1 kHz (1 to 20) kHz (20 to 30) kHz 8.9 mV + 0.22 mV/V 3.4 mV + 80 µV/V 1.7 mV + 47 µV/V 3.5 mV + 72 µV/V 5.9 mV + 0.13 mV/V 34 mV + 0.8 mV/V 0.13 V + 4.2 mV/V 0.24 V + 7 mV/V 93 mV + 0.36 mV/V 0.34 V + 1.3 mV/V 22 mV + 80 µV/V 34 mV + 0.13 mV/V 93 mV + 0.36 mV/V Fluke 5720A * 220 V range subject to 2.2E7 V- Hz limitation w/ 5725A AC Voltage – Generate3 (1 to 12) mV (12 to 120) mV (0.12 to 1.2) V (0.01 to 3) Hz (3 to 5) Hz (5 to 10) Hz 10 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.01 to 3) Hz (3 to 5) Hz (5 to 10) Hz 10 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.01 to 3) Hz (3 to 5) Hz (5 to 10) Hz (10 to 40) Hz 40.01 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 0.11 mV + 50 mV/V 8.9 µV + 1.9 mV/V 7.7 µV + 0.68 mV/V 6.1 µV + 0.12 mV/V 6.3 µV + 0.29 mV/V 16 µV + 1.2 mV/V 36 µV + 6.2 mV/V 36 µV + 6.2 mV/V 1.2 mV + 50 mV/V 30 µV + 1.9 mV/V 15 µV + 0.68 mV/V 7.4 µV + 0.11 mV/V 11 µV + 0.27 mV/V 28 µV + 0.62 mV/V 49 µV + 1.6 mV/V 49 µV + 1.6 mV/V 12 mV + 50 mV/V 0.3 mV + 1.9 mV/V 0.15 mV + 0.68 mV/V 74 µV + 0.11 mV/V 21 µV + 0.11 mV/V 42 µV + 0.23 mV/V 0.11 mV + 0.54 mV/V 0.26 mV + 1.5 mV/V 0.26 mV + 1.5 mV/V Fluke 5560A
14

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 14 of 38 Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage – Generate3 (cont) (1.2 to 12) V (12 to 120) V (120 to 330) V (330 to 1020) V (0.01 to 3) Hz (3 to 5) Hz (5 to 10) Hz (10 to 40) Hz 40.01 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.01 to 3) Hz (3 to 5) Hz (5 to 10) Hz (10 to 40) Hz 40.01 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz * (3 to 5) Hz (5 to 10) Hz 10 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (3 to 5) Hz (5 to 10) Hz 10 Hz to 10 kHz 0.12 V + 50 mV/V 3 mV + 1.9 mV/V 1.6 mV + 0.68 mV/V 0.49 mV + 0.11 mV/V 0.18 mV + 0.11 mV/V 0.33 mV + 0.23 mV/V 0.77 mV + 0.54 mV/V 2.5 mV + 1.6 mV/V 2.5 mV + 1.6 mV/V 1.2 V + 50 mV/V 30 mV + 1.9 mV/V 16 mV + 0.68 mV/V 4.8 mV + 0.11 mV/V 1.8 mV + 0.11 mV/V 3.3 mV + 0.23 mV/V 7.7 mV + 0.54 mV/V 39 mV + 1.6 mV/V 0.3 V + 1.9 mV/V 0.16 V + 0.68 mV/V 21 mV + 0.11 mV/V 36 mV + 0.23 mV/V 0.16 V + 1.2 mV/V 0.7 V + 1.9 mV/V 0.3 V + 0.68 mV/V 0.12 V + 0.11 mV/V Fluke 5560A * Max output 70 V AC Voltage3 – Measure Up to 200 mV (1 to 10) Hz (10 to 40) Hz (40 to 100) Hz 100 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz 13 µV + 0.16 µV/V 4 µV + 0.12 µV/V 4.1µV + 0.1 µV/V 2.1 µV + 0.1 µV/V 4.1 µV + 0.13 µV/V 7.9 µV + 0.31 µV/V 19 µV + 0.66 µV/V Fluke 8508A
15

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 15 of 38 Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage3 – Measure (cont) 200 mV to 2 V (2 to 20) V (20 to 200) V (200 to 1050) V (1 to 10) Hz (10 to 40) Hz (40 to 100) Hz 100 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz (1 to 10) Hz (10 to 40) Hz (40 to 100) Hz 100 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz (1 to 10) Hz (10 to 40) Hz (40 to 100) Hz 100 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz (1 to 10) Hz (10 to 40) Hz 40 Hz to 10 kHz (10 to 30) kHz (30 to 100) kHz 0.15 mV + 0.15 mV/V 30 µV + 0.11 mV/V 28 µV + 88 µV/V 26 µV + 74 µV/V 31 µV + 0.11 mV/V 0.27 mV + 0.13 mV/V 0.24 mV + 0.51 mV/V 2.1 mV + 2.3 mV/V 0.24 mV + .016 mV/V 0.11 mV + 0.12 mV/V 0.29 mV + 78 µV/V 40 µV + 74 µV/V 72 µV + 0.11 mV/V 0.1 mV + 0.21 mV/V 0.25 mV + 0.51 mV/V 2.1 mV + 2.3 mV/V 11 mV + 0.16 mV/V 2.0 mV + 0.12 mV/V 2.0 mV + 90 µV/V 1.9 mV + 76 µV/V 2 mV + 0.11 mV/V 4.1 mV + 0.21 mV/V 19 mV + 0.51 mV/V 0.19 V + 2.3 mV/V 67 mV + 0.15 mV/V 26 mV + 0.11 mV/V 3300 mV + 0.11 mV/V 49 mV + 0.2 mV/V 0.21 V + 0.54 mV/V Fluke 8508A AC High Voltage3, 6 – Measure (1 to 10) kVrms 60 Hz (10 to 50) kVrms 60 Hz 9.6 V + 0.8 V/kV 14 V + 1.2 V/kV Vitrek 4700 HV meter with Vitrek HVL-70 probe
16--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 16 of 38 Parameter/Range Frequency CMC2, 4 (±) Comments AC Current3, 6 – Generate Up to 220 µA 220 µA to 2.2 mA (2.2 to 22) mA (22 to 220) mA 220 mA to 2.2 A (2.2 to 11) A (11 to 20.5) A (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz 20 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (45 to 100) Hz 100 Hz to 1 kHz (1 to 5) kHz 63 nA + 0.13 nA/µA 12 nA + 0.14 nA/µA 9 nA + 0.11 nA/µA 15 nA + 0.25 nA/µA 75 nA + 0.9 nA/µA 0.69 µA + 13 nA/µA 93 nA + 0.23 µA/mA 67 nA + 0.14 µA/mA 60 nA + 0.11 µA/mA 0.15 µA + 0.18 µA/mA 0.85 µA + 0.9 µA/mA 3.4 µA + 8 µA/mA 0.92 µA + 0.23 µA/mA 0.69 µA + 0.14 µA/mA 0.6 µA + 0.11 µA/mA 0.95 µA + 0.18 µA/mA 7 µA + 0.9 µA/mA 14 µA + 3.2 µA/A 9.3 µA + 0.23 µA/mA 6.8 µA + 0.14 µA/mA 5 µA + 0.11 µA/mA 7.5 µA + 0.18 µA/mA 30 µA + 0.9 µA/mA 0.27 mA + 3.2 µA/mA 89 µA + 0.24 mA/A 0.17 mA + 0.39 mA/A 1.5 mA + 6 mA/A 1.1 mA + 0.4 mA/A 2.3 mA + 0.85 mA/A 8 mA + 3.3 mA/A 15 mA + 0.96 mA/A 17 mA + 1.2 mA/A 0.27 A + 24 mA/A Fluke 5720A Fluke 552XA Fluke 5720A Fluke 552XA Fluke 5720A Fluke 552XA Fluke 5720A Fluke 552XA Fluke 5720A 5720A w/5725A 552XA
to 20.5 A
17

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 17 of 38 Parameter/Range Frequency CMC2, 4 (±) Comments AC Current – Generate3 (12 to 120) µA (0.12 to 1.2) mA (1.2 to 12) mA (12 to 120) mA (0.12 to 1.2) A (1.2 to 3.1) A (3.1 to 12) A (12 to 30) A (3 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (3 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (3 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (3 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (3 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (3 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (3 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (3 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz 12 nA + 0.19 mA/A 12 nA + 0.19 mA/A 12 nA + 0.19 mA/A 52 nA + 1.2 mA/A 1 µA + 3.9 mA/A 0.13 µA + 0.19 mA/A 0.13 µA + 0.19 mA/A 0.13 µA + 0.19 mA/A 0.25 µA + 1.2 mA/A 5.5 µA + 3.9 mA/A 1.3 µA + 0.19 mA/A 1.3 µA + 0.19 mA/A 1.3 µA + 0.19 mA/A 2.5 µA + 1.2 mA/A 15 µA + 3.9 mA/A 13 µA + 0.19 mA/A 6.5 µA + 0.12 mA/A 10 µA + 0.19 mA/A 25 µA + 1.2 mA/A 0.15 mA + 3.9 mA/A 0.13 mA + 0.18 mA/A 75 µA + 0.19 mA/A 0.1 mA + 0.19 mA/A 0.53 mA + 1.9 mA/A 0.77 mA + 3.9 mA/A 0.85 mA + 0.29 mA/A 0.58 mA + 0.23 mA/A 0.65 mA + 0.29 mA/A 2.8 mA + 1.9 mA/A 1.9 mA + 0.29 mA/A 1.2 mA + 0.23 mA/A 1.7 mA + 0.29 mA/A 6.9 mA + 1.9 mA/A 19 mA + 0.78 mA/A 15 mA + 0.54 mA/A 55 mA + 3.9 mA/A Fluke 5560A
18--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 18 of 38 Parameter/Range Frequency CMC2, 4 (±) Comments AC Current Clamps – Toroidal: (10 to 16.5) A (16.5 to 150) A (150 to 1025) A (10 to 16.5) A (16.5 to 150) A (150 to 1025) A Non-Toroidal: (10 to 16.5) A (16.5 to 150) A (150 to 1025) A (10 to 16.5) A (16.5 to 150) A (150 to 1025) A (120 to 6000) A (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz 10 Hz to 1 kHz 26 mA + 2.1 mA/A 50 mA + 1.9 mA/A 0.34 A + 1.9 mA/A 60 mA + 6 mA/A 0.11 A + 5.3 mA/A 0.86 A + 5.3 mA/A 60 mA + 3.8 mA/A 0.23 A + 3.7 mA/A 1.2 A + 3.7 mA/A 90 mA + 7.2 mA/A 0.28 A + 6.7 mA/A 1.6 A + 6.7 mA/A 1 A + 4.7 mA/A Fluke 552XA with 5500A/coil Fluke 552XA with 5500A/coil 52120A with coil 6KA AC Current3 – Measure Up to 200 µA 200 µA to 2 mA (2 to 20) mA (20 to 200) mA (1 to 10) Hz 10 Hz to 10 kHz (10 to 30) kHz (30 to 100) kHz (1 to 10) Hz 10 Hz to 10 kHz (10 to 30) kHz (30 to 100) kHz (1 to 10) Hz 10 Hz to 10 kHz (10 to 30) kHz (30 to 100) kHz (1 to 10) Hz 10 Hz to 10 kHz (10 to 30) kHz 0.23 µA + 0.13 nA/A 19 nA + 48 pA/A 19 nA + 62 pA/A 19 nA + 3.1 nA/A 0.42 µA + 0.25 µA/A 0.56 µA + 0.19 µA/A 0.25 µA + 0.62 µA/A 0.5 µA + 3.1 µA/A 48 µA + 32 nA/A 1.9 µA + 0.29 µA/A 1.9 µA + 0.62 µA/A 2.2 µA + 3.1 µA/A 24 µA + 0.29 µA/A 19 µA + 0.28 µA/A 19 µA + 0.57 µA/A Fluke 8508A
10 to 1025 A
19

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 19 of 38 Parameter/Range Frequency CMC2, 4 (±) Comments AC Current3 – Measure (cont) 200 mA to 2 A (2 to 20) A (1 to 10) Hz 10 Hz to 10 kHz (10 to 30) kHz 10 Hz to 2 kHz (2 to 10) kHz 0.4 mA + 0.5 mA/A 0.26 mA + 0.67 mA/A 0.42 mA + 2.5 mA/A 1.9 mA + 0.72 mA/A 2.1 mA + 1.9 mA/A Fluke 8508A AC Resistance3 – Generate, Fixed Points DC to 13 MHz See matrix below. Interpolate CMC’s for frequencies between stated cardinal points. HP 16074A 0 Ω 0.1 Ω 1 Ω 10 Ω 100 Ω 1 kΩ 10 kΩ 100 kΩ DC 6.6 % 0.0061 % 0.0023 % 0.00087 % 0.000 61 % 0.000 87 % 100 Hz 0.0037 % 0.0035 % 0.0021 0.000 35 % 1 kHz 0.0035 % 10 kHz 0.0035 % 100 kHz 0.0035 % 1 MHz 0.0037 % 0.0023 % 0.0011 % 2 MHz 0.0053 % 0.0045 % 0.004 % 3 MHz 0.0096 % 0.0097 % 0.0092 % 0.009 % 5 MHz 0.025 % 10 MHz 0.1 % 13 MHz 0.17 % Parameter/Equipment Range CMC2, 4, 5 (±) Comments Duty Cycle3 – Generate (1 to 9.99) % (10 to 49.99) % 50 % (50.01 to 90) % (90.01 to 99) 0.32 % 0.02 % 0.013 % 0.02 % 0.31 % Fluke 5522A
20

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 20 of 38 Parameter/Range Frequency CMC2, 4, 5 (±) Comments AC Power3 – Generate See Table below See Table below Fluke 5520A (45 to 65) Hz (3.366 to 33.66) W (33.66 to 336.6) W (0.3366 to 1.122) kW (1.122 to 3.06) kW (3.06 to 11.22) kW (11.22 to 20.9) kW Ø 0° PF=1.000 0.052 % 0.068 % 0.076 % 0.083 % 0.17 % Ø 10° PF=0.985 0.06 % 0.075 % 0.082 % 0.088 % 0.18 % Ø 20° PF=0.940 0.082 % 0.093 % 0.099 % 0.1 % 0.18 % Ø 30° PF=0.866 0.11 % 0.12 % 0.13 % 0.2 % Ø 40° PF=0.766 0.16 % 0.17 % 0.23 % Ø 50° PF=0.643 0.21 % 0.22 % 0.27 % Ø 60° PF=0.500 0.31 % 0.35 % (45 to 65) Hz (3.366 to 33.66) W (33.66 to 336.6) W (0.3366 to 1.122) kW (1.122 to 3.06) kW (3.06 to 11.22) kW (11.22 to 20.9) kW Ø 70° PF=0.342 0.48 % 0.49 % 0.51 % Ø 80° PF=0.174 0.99 % 1 % (65 to 500) Hz (33.66 to 336.6) W (0.3366 to 1.122) kW (1.122 to 3.06) kW (3.06 to 11.22) kW (11.22 to 20.9) kW Ø 0° PF=1.000 0.052 % 0.068 % 0.076 % 0.12 % 0.21 % Ø 10° PF=0.985 0.094 % 0.1 % 0.11 % 0.14 % 0.22 % Ø 20° PF=0.940 0.17 % 0.18 % 0.2 % 0.26 % Ø 30° PF=0.866 0.26 % 0.28 % 0.33 % Ø 40° PF=0.766 0.37 % 0.39 % 0.42 % Ø 50° PF=0.643 0.53 % 0.56 % Ø 60° PF=0.500 0.76 % 0.77 % 0.78 % Ø 70° PF=0.342 1.2 %
21

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 21 of 38 Parameter/Range Frequency CMC2, 4, 5 (±) Comments AC Power – Generate3 See Table below See Table below Fluke 5560A (65 to 500) Hz (33.66 to 336.6) W (0.3366 to 1.122) kW (1.122 to 3.06) kW (3.06 to 11.22) kW (11.22 to 20.9) kW Ø 80° PF=0.174 2.5 % 500 Hz to 1 kHz (33.66 to 336.6) W (0.3366 to 1.122) kW (1.122 to 3.06) kW (3.06 to 11.22) kW (11.22 to 20.9) kW Ø 0° PF=1.000 0.052 % 0.068 % 0.076 % 0.12 % 0.21 % (45 to 65) Hz (1.22 to 12.2) W (12.2 to 122) W (0.122 to 1.22) kW (1.22 to 3.16) kW (3.16 to 12.2) kW (12.2 to 30.8) kW Ø 0° PF=1.000 0.038 % 0.029 % 0.034 % 0.048 % 0.04 % 0.11 % Ø 10° PF=0.985 0.049 % 0.042 % 0.046 % 0.057 % 0.051 % 0.11 % Ø 20° PF=0.940 0.074 % 0.07 % 0.072 % 0.079 % 0.075 % 0.12 % Ø 30° PF=0.866 0.11 % 0.15 % Ø 40° PF=0.766 0.15 % Ø 50° PF=0.643 0.21 % Ø 60° PF=0.500 0.3 % Ø 70° PF=0.342 0.48 % Ø 80° PF=0.174 0.99 % (65 to 500) Hz (12.2 to 122) W (0.122 to 1.22) kW (1.22 to 3.16) kW (3.16 to 12.2) kW (12.2 to 30.8) kW Ø 0° PF=1.000 0.029 % 0.034 % 0.048 % 0.04 % 0.11 % Ø 10° PF=0.985 0.068 % 0.071 % 0.078 % 0.074 % 0.12 % Ø 20° PF=0.940 0.14 % 0.17 % Ø 30° PF=0.866 0.2 % 0.21 % 0.23 % Ø 40° PF=0.766 0.29 % 0.3 % 0.31 % Ø 50° PF=0.643 0.42 %
22

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 22 of 38 Parameter/Range Frequency CMC2, 4, 5 (±) Comments AC Power – Generate3 (cont) See Table below See Table below Fluke 5560A (65 to 500) Hz (12.2 to 122) W (0.122 to 1.22) kW (1.22 to 3.16) kW (3.16 to 12.2) kW (12.2 to 30.8) kW Ø 60° PF=0.500 0.61 % Ø 70° PF=0.342 0.96 % Ø 80° PF=0.174 2 % 500 Hz to 1 kHz (12.2 to 122) W (0.122 to 1.22) kW (1.22 to 3.16) kW (3.16 to 12.2) kW (12.2 to 30.8) kW Ø 0° PF=1.000 0.029 % 0.034 % 0.048 % 0.04 % 0.11 % Ø 10° PF=0.985 0.13 % 0.16 % Ø 20° PF=0.940 0.26% 0.28 % Ø 30° PF=0.866 0.41% 0.42 % Ø 40° PF=0.766 0.59 % 0.6 % Ø 50° PF=0.643 0.83 % Ø 60° PF=0.500 1.2 % Ø 70° PF=0.342 1.9 % Ø 80° PF=0.174 4 % (1 to 5) kHz (6 to 60) W (60 to 600) W (0.6 to 1.55) kW Ø 0° PF=1.000 0.071 % 0.082 % Ø 10° PF=0.985 0.64 % Ø 20° PF=0.940 1.3 % Ø 30° PF=0.866 2 % Ø 40° PF=0.766 2.8 % Ø 50° PF=0.643 4 %
23

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 23 of 38 Parameter/Range Frequency CMC2, 4, 5 (±) Comments AC Power – Generate3 (cont) See Table below See Table below Fluke 5560A (5 to 10) kHz (3 to 30) W (30 to 300) W Ø 0° PF=1.000 0.28 % 0.34 % Ø 10° PF=0.985 1.4 % (5 to 10) kHz (3 to 30) W (30 to 300) W Ø 20° PF=0.940 2.7 % Ø 30° PF=0.866 4.2 % (10 to 30) kHz (3 to 300) W Ø 0° PF=1.000 1.1 % Ø 10° PF=0.985 3.4 % Ø 20° PF=0.940 5.9% Phase3 (PF=1) – Generate (10 to 65) Hz (65 to 500) Hz 500 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (3 to 65) Hz (65 to 500) Hz 500 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz Ø 0.1° Ø 0.26° Ø 0.51° Ø 2.6° Ø 5.1° Ø 10° Ø 0.1° Ø 0.2° Ø 0.4° Ø 1.9° Ø 3.9° Ø 7.8° Fluke 5520A Fluke 5560A Capacitance3 – Generate (0.19 to 0.3999) nF (0.4 to 1.0999) nF (1.1 to 3.2999) nF (3.3 to 10.9999) nF (11 to 32.9999) nF (33 to 109.999) nF (110 to 329.999) nF 10 Hz to 10 kHz 10 Hz to 10 kHz 10 Hz to 3 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz 8.8 pF + 4 pF/nF 9.7 pF + 4 pF/nF 13 pF + 4 pF/nF 15 pF + 2 pF/nF 0.1 nF + 2 pF/nF 0.15 nF + 2 pF/nF 0.46 nF + 2 pF/nF Fluke 5520A
24--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 24 of 38 Parameter/Range Frequency CMC2, 4, 5 (±) Comments Capacitance3 – Generate (cont) (0.33 to 1.0999) µF (1.1 to 3.299 99) µF (3.3 to 10.9999) µF (11 to 32.9999) µF (33 to 109.999) µF (110 to 329.999) µF (0.33 to 1.099 99) mF (1.1 to 3.2999) mF (3.3 to 10.9999) mF (11 to 32.9999) mF (33 to 110) mF 200 pF to 1.2 nF (1.2 to 12) nF (> 3 to 12) nF (12 to 120) nF (> 30 to 120) nF (0.12 to 1.2) µF (1.2 to 12) µF (12 to 120) µF (0.12 to 1.2) mF (1.2 to 12) mF (12 to 120) mF (10 to 600) Hz (10 to 300) Hz (10 to 150) Hz (10 to 120) Hz (10 to 80) Hz (10 to 50) Hz (10 to 20) Hz (0 to 6) Hz (0 to 2) Hz (0 to 0.6) Hz (0 to 0.2) Hz 100 Hz to 10 kHz 150 Hz to 5 kHz (10 to 150) Hz 200 Hz to 1.3 kHz (10 to 200) Hz (2 to 310) Hz (0.5 to 110) Hz (0.5 to 40) Hz (0.1 to 11) Hz (0.03 to 4) Hz (0.01 to 1.3) Hz 1.5 nF + 2 nF/µF 4.6 nF + 2 nF/µF 15 nF + 2 nF/µF 59 nF + 3.2 nF/µF 0.2 µF + 3.6 nF/µF 0.64 µF + 3.6 nF/µF 2 µF + 3.6 µF/mF 7 µF + 3.5 µF/mF 38 µF + 2.6 µF/mF 90 µF + 6 µF/mF 0.37 mF + 8.8 µF/mF 2.4 pF + 0.86 mF/F 6.2 pF + 0.9 mF/F 7.8 pF + 0.9 mF/F 43 pF + 1 mF/F 61 pF + 1 mF/F 0.42 nF + 1 mF/F 4.2 nF + 1 mF/F 40 nF + 1.2 mF/F 0.48 µF + 1.9 mF/F 5.3 µF + 1.9 mF/F 77 µF + 3.9 mF/F Fluke 5520A Fluke 5560A Capacitance – Measure 1 pF 10 pF 100 pF 1 nF 10 nF 100 nF 50 Hz to 1 kHz (1 to 100) kHz (50 to 300) Hz 300 Hz to 10 kHz (10 to 20) kHz (20 to 100) kHz (50 to 100) Hz 100 Hz to 1 kHz (1 to 20) kHz (20 to 100) kHz (50 to 300) Hz 300 Hz to 20 kHz (20 to 100) kHz 50 Hz to 20 kHz (20 to 100) kHz 50 Hz to 20 kHz (20 to 100) kHz 12 % 1.2 % 12 % 1.2 % 0.13 % 0.47 % 12 % 1.2 % 0.13 % 0.47 % 1.2 % 0.13 % 0.47 % 0.13 % 0.47 % 0.13 % 0.47 % Fluke PM6304
to 120 mF
25

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 25 of 38 Parameter/Range Frequency CMC2, 4, 5 (±) Comments Capacitance – Measure (cont) 1 µF 10 µF 100 µF 50 Hz to 20 kHz (20 to 100) kHz 50 Hz to 20 kHz (20 to 100) kHz 50 Hz to 10 kHz (10 to 20) kHz (20 to 100) kHz 0.13 % 0.47 % 0.13 % 1.2 % 0.13 % 1.2 % 12 % Fluke PM6304 Capacitance – Generate, Fixed Points3 1 pF 10 pF 100 pF 1000 pF 1 kHz 1 MHz 2 MHz 3 MHz 4 MHz 5 MHz 10 MHz 13 MHz 1 kHz 1 MHz 2 MHz 3 MHz 4 MHz 5 MHz 10 MHz 13 MHz 1 kHz 1 MHz 2 MHz 3 MHz 4 MHz 5 MHz 10 MHz 13 MHz 1 kHz 1 MHz 2 MHz 3 MHz 4 MHz 5 MHz 10 MHz 13 MHz 0.000 05 pF 0.000 09 pF 0.000 23 pF 0.000 41 pF 0.000 63 pF 0.0009 pF 0.0025 pF 0.0037 pF 0.0001 pF 0.000 41 pF 0.000 42 pF 0.0004 pF 0.0005 pF 0.0006 pF 0.0012 pF 0.0016 pF 0.001 pF 0.004 pF 0.005 pF 0.0067 pF 0.009 pF 0.013 pF 0.033 pF 0.049 pF 0.043 pF 0.065 pF 0.15 pF 0.28 pF 0.44 pF 0.62 pF 1.9 pF 2.8 pF Agilent 16380A capacitance set
26

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 26 of 38 Parameter/Range Frequency CMC2, 4, 5 (±) Comments Capacitance – Generate, Fixed Points3 (cont) 10 nF 100 nF 1 µF 120 Hz to 100 kHz 120 Hz to 200 kHz 120 Hz > 120 Hz to 10 kHz (> 10 to 100) kHz 0.51 pF 5.1 pF 65 pF 57 pF 81 pF Agilent 16380C capacitance set AC Flatness3 – Measure 10 Hz 100 Hz to 100 kHz 500 kHz 1 MHz (3 to 8) MHz 10 MHz 15 MHz 20 MHz 26 MHz 30 MHz 0.2 % 0.069 % 0.11 % 0.11 % 0.21 % 0.21 % 0.21 % 0.23 % 0.36 % 0.55 % EL1100 3V TVC Inductance – Generate & Measure3, 4 100 µH 1 mH 10 mH 100 mH 1 H 10 H 100 Hz to 2 kHz 5 kHz 10 kHz 20 kHz 100 kHz (100 to 200) Hz 500 Hz to 20 kHz 100 kHz 100 Hz 200 Hz to 20 kHz 100 Hz to 10 kHz 20 kHz 100 Hz to 5 kHz 100 Hz to 1 kHz 2 kHz 1.2 % 0.13 % 0.14 % 0.19 % 0.47 % 1.2 % 0.12 % 0.46 % 1.2 % 0.12 % 0.14 % 0.4 % 0.12 % 0.12 % 0.22 % General Radio 1491- G & Fluke PM6304
27

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 27 of 38 Parameter/Range Frequency CMC2, 4, 5 (±) Comments Inductance – Generate3 (13 to 120) µH (0.120 01 to 1.2) mH (1.2001 to 3.3) mH (3.3 to 12) mH (12 to 83) mH (83 to 120) mH (0.120 01 to 0.65) H (0.65 to 1.2) H (1.2001 to 5.5) H (490 to 550) Hz (550 to 999) Hz 1 kHz (1.001 to 13) kHz (13 to 17) kHz (260 to 330) Hz (330 to 999) Hz 1 kHz (1.001 to 1.6) kHz (1.6 to 2.5) kHz (0.5 to 999) Hz 110 Hz (111 to 800) Hz (800 to 980) Hz (0.5 to 109) Hz 110 Hz (111 to 1000) Hz (1 to 1.4) kHz (0.1 to 99) Hz 100 Hz (101 to 180) Hz (180 to 230) Hz (0.1 to 99) Hz 100 Hz (101 to 320) Hz (320 to 1000) Hz (0.05 to 9.9) Hz 10 Hz (10.1 to 30) Hz (30 to 50) Hz (0.05 to 9.9) Hz 10 Hz (10.1 to 100) Hz (100 to 170) Hz (0.01 to 2.99) Hz 3 Hz (3.01 to 8) Hz (8 to 16) Hz 1.5 % 0.67 % 0.38 % 0.67 % 1.5 % 1.4 % 0.49 % 0.2 % 0.49 % 1.4 % 0.74 % 0.46 % 0.74 % 1.6 % 0.49 % 0.2 % 0.49 % 1.4 % 0.53 % 0.25 % 0.53 % 1.4 % 0.49 % 0.2 % 0.49 % 1.4 % 0.61 % 0.32 % 0.6 % 1.5 % 0.52 % 0.24 % 0.52 % 1.4 % 0.68 % 0.4 % 0.68 % 1.6 % Fluke 5560A
28--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 28 of 38 Parameter/Range Frequency CMC2, 4, 5 (±) Comments Inductance – Generate3 (cont) (5.5 to 12) H (12.001 to 30) H (30 to 120) H (0.01 to 2.99) Hz 3 Hz (3.01 to 19) Hz (19 to 37) Hz (0.005 to 1.99) Hz 2 Hz (2.01 to 4) Hz (4 to 16) Hz (0.005 to 1.99) Hz 2 Hz (2.01 to 7) Hz (7 to 14) Hz 0.57 % 0.28 % 0.57 % 1.4 % 0.89 % 0.61 % 0.89 % 1.8 % 0.61 % 0.32 % 0.6 % 1.5 % Fluke 5560A Phase – Measure Up to 360° (10 to 32) mV 32 mV to 100 V (100 to 320) V (10 to 32) mV 32 mV to 100 V (10 to 100) mV 100 mV to 100 V (10 to 100) mV 100 mV to 100 V (10 to 100) mV 100 mV to 100 V 10 Hz to 5 kHz (5 to 10) kHz (10 to 40) kHz (40 to 50) kHz (50 to 100) kHz 0.23° 0.059° 0.12° 0.23° 0.059° 0.41° 0.061° 0.41° 0.071° 0.41° 0.41° Krohn-Hite 6620A Distortion – Measure3, 6 20 Hz to 20 kHz (20 to 100) kHz 100 kHz to 2.9 GHz (2.9 to 6.5) GHz (6.5 to 13.2) GHz (13.2 to 50) GHz 1.2 dB 2.3 dB 2.4 dB 3.1 dB 3.6 dB 4.8 dB Agilent 8903A Keysight 8568EC
to 360 °
29--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 29 of 38 Parameter/Range Frequency CMC2, 4, 5 (±) Comments Oscilloscopes3 – Amplitude – DC Signal: 50 Ω Load 1 MΩ Load Amplitude – Squarewave: 50 Ω Load 1 MΩ Load Edge into 50 Ω Bandwidth Time Markers (-6.6 to 6.6) V (-130 to 130) V 1 mV to 6.6 Vp-p 1 mV to 130 Vp-p 10 Hz to 1 kHz 1 mV to 130 Vp-p (1 to 100) kHz ≤ 300 ps (up to 2 MHz) ≤ 350 ps (above 2 MHz) 50 kHz ref 50 kHz to 100 MHz (100 to 300) MHz (300 to 600) MHz (600 to 1100) MHz 5 s to 50 ms 20 ms to 1 ns 33 µV + 2 mV/V 33 µV + 0.39 mV/V 91 µV + 4.3 mV/V 0.2 mV + 0.8 mV/V 0.24 mV + 2 mV/V 82 ps 82 ps 0.33 mV + 1.7 mV/V 0.4 mV + 31 mV/V 0.43 mV + 36 mV/V 0.53 mV + 57 mV/V 0.58 mV + 67 mV/V 0.0021 % + (T/1000) % 0.000 36 % Fluke 5520A with SC1100 T = time in seconds IV. Electrical – RF/Microwave Parameter/Equipment Range CMC2, 4, 5 (±) Comments Power Meter3 Power Reference @ 1 mW Power Accuracy 50 MHz 3 µW to 100 mW 0.45 % 0.29 % Agilent 432A, 478A-H55, Agilent 3458A Range calibrator
to 130 V
30

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 30 of 38 Parameter/Equipment Range CMC2, 4, 5 (±) Comments Relative Power3 – Measure (0 to -10) dB (-10 to -20) dB (-20 to -30) dB (-30 to -40) dB (-40 to -50) dB (-50 to -60) dB (-60 to -70) dB (-70 to -80) dB (-80 to -90) dB (-90 to -100) dB (-100 to -110) dB (-110 to -120) dB (-120 to -127) dB (0 to -10) dB (-10 to -20) dB (-20 to -30) dB (-30 to -40) dB (-40 to -50) dB (-50 to -60) dB (-60 to -70) dB (-70 to -80) dB (-80 to -90) dB (-90 to -100) dB (-100 to -110) dB (-110 to -120) dB (-120 to -127) dB 2.5 MHz to 1.3 GHz (1.3 to 26.5) GHz 0.047 dB 0.06 dB 0.074 dB 0.087 dB 0.1 dB 0.1 dB 0.11 dB 0.12 dB 0.13 dB 0.15 dB 0.15 dB 0.28 dB 0.29 dB 0.066 dB 0.06 dB 0.074 dB 0.087 dB 0.1 dB 0.1 dB 0.11 dB 0.12 dB 0.13 dB 0.15 dB 0.15 dB 0.28 dB 0.29 dB 8902A Absolute Power3 – Measure (0 to +20) dBm (-10 to 0) dBm (-60 to -10) dBm (+10 to +20) dBm 9 kHz to 16 GHz (16 to 18) GHz 9 kHz to 16 GHz (16 to 18) GHz 9 kHz to 2 GHz (2 to 16) GHz (16 to 18) GHz 100 kHz to 4.2 GHz (4.2 to 18) GHz (18 to 26.5) GHz 2.6 % 2.8 % 3.1 % 3.3 % 3.6 % 3.7 % 3.8 % 3.6 % 3.7 % 4.7 % Agilent E4418B: Agilent E9304A Agilent 8482A Agilent 8481A Agilent 8485A
31--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 31 of 38 Parameter/Range Frequency CMC2, 4, 5 (±) Comments Absolute Power3 – Measure (cont) (-30 to +10) dBm 100 kHz to 4.2 GHz (4.2 to 18) GHz (18 to 26.5) GHz 1.1 % 1.3 % 3.2 % Agilent 8482A Agilent 8481A Agilent 8485A Amplitude Modulation3 – Measure Rate: 50 Hz to 10 kHz Depths: (5 to 99) % Rate: 20 Hz to 10 kHz Depths: to 99 % Rate: 50 Hz to 50 kHz Depths: (5 to 99) % Rate: 20 Hz to 100 kHz Depths: to 99 % Rate: 50 Hz to 50 kHz Depths: (5 to 99) % Rate: 20 Hz to 100 kHz Depths: to 99 % 150 kHz to 10 MHz 150 kHz to 10 MHz (0.01 to 1.3) GHz (0.01 to 1.3) GHz (1.3 to 26.5) GHz (1.3 to 26.5) GHz 0.14 % depth + 0.024 % depth/% depth 0.11 % depth + 0.023 % depth/% depth 0.15 % depth + 0.01 % depth/% depth 0.11 % depth + 0.023 % depth/% depth 0.33 % depth + 0.008 % depth/% depth 0.31 % depth + 0.021 % depth/% depth 8902A Frequency Modulation3 – Measure Rate: 20 Hz to 10 kHz Dev.: ≤ 40 kHz Peak Rate: 50 Hz to 100 kHz Dev.: ≤ 400 kHz Peak Rate: 20 Hz to 200 kHz Dev.: ≤ 400 kHz Peak Rate: 50 Hz to 100 kHz Dev.: ≤ 400 kHz Peak Rate: 20 Hz to 200 kHz Dev.: ≤ 400 kHz Peak 250 kHz to 10 MHz (0.01 to 1.3) GHz (0.01 to 1.3) GHz (1.3 to 26.5) GHz (1.3 to 26.5) GHz 3.5 Hz + 16 Hz/kHz 3.5 Hz + 7.8 Hz/kHz 6.8 Hz + 39 Hz/kHz 6.8 Hz + 7.8 Hz/kHz 6.8 Hz + 39 Hz/kHz 8902A
-30 to 10 dBm
32

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 32 of 38 Parameter/Range Frequency CMC2, 4 (±) Comments Phase Modulation3 – Measure Rate: 200 Hz to 10 kHz (0 to 100) rad Rate: 200 Hz to 20 kHz (0 to 100) rad Rate: 200 Hz to 20 kHz (0 to 100) rad 150 kHz to 10MHz (0.01 to 1.3) GHz (1.3 to 26.5) GHz 36 mrad + 37 mrad/rad 36 mrad + 37 mrad/rad 36 mrad + 37 mrad/rad 8902A V. Mechanical Parameter/Equipment Range CMC2, 5, 8 (±) Comments Accelerometers6 – Amplitude Response (mV/g Sensitivity) @ Test Levels From (1 to 10) g (0.5 to < 1) Hz (1 to < 100) Hz 100 Hz > 100 Hz to 1 kHz (> 1 to 5) kHz (> 5 to 10) kHz 1.8 % 1 % 0.8 % 1 % 1.4 % 1.9 % VR9500, Reference Accelerometer Mass6 – Measure Class 2 or Higher 1 mg to 5 g 10 g 20 g 30 g 50 g 100 g 200 g 300 g 500 g 13 µg 15 µg 19 µg 28 µg 29 µg 51 µg 110 µg 1.1 mg 1.2 mg Mass comparator, Class 1 weights (ABBA method) Mass – Direct Weigh Up to 50 g (50 to 100) g (100 to 205) g Up to 620 g Up to 6 kg 42 µg 61 µg 120 µg 2.9 mg 29 mg Electronic balances
33

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 33 of 38 Parameter/Equipment Range CMC2, 5, 8 (±) Comments Balances3, 6 0.0001 g Resolution 0.001 g Resolution 0.01 g Resolution 0.1 g & 1 g Resolution Up to 500 mg > 500 mg to 5 g > 5 g to 15 kg Up to 50 g (> 50 to 100) g (> 100 to 300) g > 300 g to 15 kg Up to 500 g Up to 15 kg 0.82 x R 0.91 x R 1.2 x R 0.83 x R 0.87 x R 1.0 x R 1.2 x R 0.83 x R 1.4 x R Class 1, Class 6 weights Scales3, 6 Up to 2000 lb 0.82 x R Class 6 weights Force Measuring Equipment3, 6 – Tension & Compression Up to 500 lb 0.0023 % Class F weights Cable Tensiometers6 Up to 250 lbf (250 to 600) lbf 0.45 % 0.42 % CDI torque calibration system, tension cables Pressure – Precision Measuring Equipment6 Pneumatic3 (0.2 to 25) psia (25 to 1000) psia (0.2 to 25) psig (25 to 1000) psig (0.6 to 50) pisg (1.3 to 55) psia (1.5 to 250) psig (3.6 to 275) psia (6 to 1000) psig (14.5 to 1100) psia (8 to 17) psia (-15 to 15) psig 0.0049 % 0.0057 % 0.0014 % 0.0031 % 0.0012 % 0.0012 % 0.0014 % 0.0014 % 0.002 % 0.002 % 0.01 % 0.003 psi Ruska 2465 gas piston gauge Fluke PG7601 with AMH-38 Mensor CPC6050 w/ sensor range: (8 to 17) psia module (-15 to +15) psig module
34

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 34 of 38 Parameter/Equipment Range CMC2, 5, 8 (±) Comments Pressure – Precision Measuring Equipment6 (cont) Pneumatic3 (-15 to 50) psig (> 50 to 150) psig (-15 to 100) psig (> 100 to 300) psig (-15 to 330) psig (> 300 to 1000) psig (4 to 854) in∙H 2O 0.0044 psi 0.008 % 0.0083 psi 0.008 % 0.027 psi 0.008 % 0.0087 % Mensor CPC6050 w/ sensor range: (-15 to 150) psig module (-15 to 300) psig module (-15 to 1000) psig module Ametek PK-854WC-SS Pressure – Precision Measuring Equipment3, 6 Pneumatic (0 to 0.25) inH2O (0 to 0.5) inH2O Up to ± 1 inH2O (0 to 16) inH2O (-8 to 8) inH2O (-80 to 80) inH2O ± (0 to 25) inH2O (-100 to -25) inH2O (25 to 100) inH2O (-15 to 30) psi (0.1 to 10) in∙H2O (14.5 to 1160) psig (29 to 1174) psia (72.5 to 5800) psig (87 to 5814.5) psia 0.000 24 inH 2O 0.000 41 inH2O 0.0014 inH2O 0.011 inH2O 0.000 045 inH2O + 0.0012 inH2O/inH2O 0.000 41 inH2O + 0.0012 inH2O/inH2O 0.0014 inH 2O + 0.000 047 inH2O/inH2O 0.011 % 0.028 psi 0.034 in∙H2O 0.00067 psi + 0.002 % 0.002 psi + 0.002 % 0.0025 psi + 0.002 % 0.0035 psi + 0.002 % AQS-1 modules w/digital display Furnace Control PPC500 Fluke 7250LP Fluke 700PD7 Fluke 700P01 DHI PG7202 with: PC7200-100 piston PC7200-500 piston
35

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 35 of 38 Parameter/Equipment Range CMC2, 5, 8 (±) Comments Pressure – Precision Measuring Equipment3, 6 (cont) Hydraulic (250 to 16 000) psig (304.5 to 16 014.5) psia (1 to 1000) psi (10 to 15 000) psi 0.016 psi + 0.0045 % 0.019 psi + 0.0045 % 0.0092 % 0.016 % DHI PG7202 with: PC7200-2 piston Ametek HK-1000 Ametek WG-15Q-1L Torque Tools3, 6 15 ozf·in to 2000 lbf·ft 0.31 % CDI torque calibration system Torque Transducers3, 6 5 ozf·in to 10 lbf·in 10 lbf·in to 250 lbf·ft (250 to 2000) lbf·ft 0.039 % 0.036 % 0.034 % Torque arms, Class 6 weights IV. Photometry Parameter/Equipment Range CMC2, 5, 8 (±) Comments Illuminance – Measuring Equipment (5 to 5200) Lux 1.6 % Meter-to-meter comparison using Konica Minolta CL200A, lamp Luminance – Measuring Equipment (0.5 to 1700) fL 1.8 % Hoffman Engineering LS-65- 8C
36AMS 2750-See scope document
37

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 37 of 38 VI. Time & Frequency Parameter/Equipment Range CMC2, 8 (±) Comments Frequency – Measuring Equipment3 0.01 Hz to 20 MHz 20 MHz to 20 GHz 0.58 µHz 0.58 mHz + 73 nHz/Hz Agilent 33220A & E8257D, GPS receiver Frequency – Measure3 0.1 Hz to 12.4 GHz 73 nHz + 12 pHz/Hz HP 53132A, GPS receiver Stopwatches & Timers3 ± (0 to 19.99) sec/day 37 ms/day Timometer Tachometers3 (1 to 100 000) rpm 0.000 35 rpm + 0.000 038 rpm/rpm Fluke 5520A ______________________ 1 This laboratory offers commercial calibration services and field calibration services. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC uncertainty found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC uncertainty. 4 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMC’s are expressed as eith er a specific value that covers the full range or as a percentage or fraction of the reading plus a fixed floor specification. 5 In the statement of CMC, R is the resolution of the unit under test; all percentages are percent of reading unless otherwise indicated. 6 Uncertainty components that can be reasonably attributed to the Unit Under Test have not been utilized in the calculation of the CMC value for this measurement parameter. 7 This scope meets A2LA’s P112 Flexible Scope Policy.
38

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1877.01) Revised 9/29/2025 Page 38 of 38 8 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 9 The contributions from the resolution of the device under calibration are not included in the CMC claim.
39ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ANSI/NCSL Z540.3-2006; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

10442 BAILEY ROAD, SUITE B, Cornelius, NC, 28031, US

35.48170, -80.85900

Open in Maps