Cameron Instruments

Guelph, Canada

Visit website
A2LA 4171.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
6
A2LA certificate
1
Sites in our directory
4
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 6 scope lines.

A2LA certificate 4171.01 · 6 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017-See scope document
2-Gas
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4171.01) Revised 04/09/2026 Page 2 of 5 Parameter/Equipment Range CMC2, 9 (±) Comments DC Current – Measure (0 to 0.1) mA (0.1 to 1) mA (1 to 4) mA (4 to 8) mA (8 to 16) mA (16 to 20) mA (20 to 24) mA (24 to 30) mA (30 to 40) mA (40 to 50) mA 1.2 µA 1.3 µA 1.8 µA 2.3 µA 3.5 µA 4.0 µA 4.6 µA 5.5 µA 11 µA 12 µA AMC910 Resistance – Generate (5 to 10) Ω (10 to 100) Ω (100 to 200) Ω (200 to 400) Ω (400 to 1000) Ω (1000 to 4000) Ω 25 mΩ 24 mΩ 27 mΩ 30 mΩ 0.35 Ω 0.36 Ω AMC910 II. Mechanical Parameter/Equipment Range CMC2, 3, 4, 5, 7 (±) Comments Gauge Pressure – Measure/Measuring Equipment Gas Gas – Differential6 (5 to 350) kPa (25 to 1750) kPa (100 to 7000) kPa (1.4 to 172) kPa (12 to 700) kPa (14 to 7000) kPa (2000 to 70 000) kPa (-31 to 10) kPa (-99 to 240) kPa (240 to 700) kPa (-99 to 1750) kPa (1750 to 7000) kPa (0 to 5000) kPa (5000 to 20 685) kPa (0 to 11 667) kPa (11 667 to 41 400) kPa (0 to 70 000) kPa (-99 to 259) kPa 0.0016 % + 0.19 Pa 0.0014 % + 0.43 Pa 0.0018 % + 3.1 Pa 0.0016 % + 0.13 Pa 0.0015 % + 0.08 Pa 0.0018 % + 0.22 Pa 0.0030 % + 19 Pa 0.010 % + 10 Pa 12 Pa 0.005 % 180 Pa 0.010 % 500 Pa 0.010 % 1400 Pa 0.012 % 9100 Pa 0.0014 % + 0.64 Pa Fluke PG7601 Ruska 2465 Fluke PG7202 BA100K – RPM4 A700KP – RPM4 A7M – PM600 A20M – PM600 A40M – RPM4 G70M – PM230 Fluke PG7601 & RPM4
-
3-Oil; Gas
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4171.01) Revised 04/09/2026 Page 3 of 5 Parameter/Equipment Range CMC2, 3, 4, 5, 7 (±) Comments Gauge Pressure – Measure/Measuring Equipment Oil (2000 to 70 000) kPa (5000 to 210 000) kPa (0 to 2000) kPa (2000 to 20 685) kPa (0 to 20 000) kPa (20 000 to 206 850) kPa 0.0029 % + 66 Pa 0.0035 % + 60 Pa 400 Pa 0.02 % 4000 Pa 0.02 % Fluke PG7202 A20M RPM4 E-DWT A200M RPM4 E-DWT Absolute Pressure – Measure/Measuring Equipment Gas Oil (5 to 350) kPa (25 to 1750) kPa (100 to 7000) kPa (1.4 to 172) kPa (12 to 700) kPa (14 to 7000) kPa (2000 to 70 000) kPa + Atmospheric Pressure (70 to 110) kPa (5 to 240) kPa (240 to 700) kPa (5 to 1750) kPa (1750 to 7000) kPa (97 to 5000) kPa (5000 to 20 685) kPa (97 to 11 667) kPa (11 667 to 41 400) kPa (97 to 70 000) kPa + Atmospheric Pressure (2000 to 70 000) kPa + Atmospheric Pressure (5000 to 210 000) kPa + Atmospheric Pressure 0.0014 % + 0.6 Pa 0.0013 % + 0.54 Pa 0.0018 % + 3.1 Pa 0.0012 % + 1.1 Pa 0.0014 % + 0.94 Pa 0.0018 % + 0.43 Pa 0.0030 % + 20 Pa 0.010 % 12 Pa 0.005 % 180 Pa 0.010 % 500 Pa 0.010 % 1400 Pa 0.012 % 9100 Pa 0.0029 % + 62 Pa 0.0035 % + 71 Pa Fluke PG7601 Ruska 2465 Fluke PG7202 and RPM4 BA100K – RPM4 A700KP – RPM4 A7M – PM600 A20M – PM600 A40M – RPM4 G70M – PM230 and Fluke RPM4 Fluke PG7202 and Fluke RPM4 Fluke PG7202 and Fluke RPM4
See scope document
4-Temperature
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4171.01) Revised 04/09/2026 Page 4 of 5 III. Thermodynamics Parameter/Equipment Range CMC2 (±) Comments Temperature – Dry Well (-100 to -40) °C (-40 to 155) °C 0.038 °C 0.037 °C RTC159 Fluke 5609 PRT Temperature – Dry Well (-45 to -35) °C (-35 to 50) °C (50 to 140) °C 0.031 °C 0.020 °C 0.023 °C Fluke 9170 Fluke 5609 PRT Temperature – Dry Well (33 to 420) °C (420 to 600) °C (600 to 660) °C 0.043 °C 0.064 °C 0.077 °C RTC700 Fluke 5609 PRT Temperature – Liquid Bath (-22 to 155) °C 0.034 °C RTC158 Fluke 5609 PRT _________________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 In the statement of CMC, percentages are to be read as percent of reading, unless otherwise noted. 4 The contributions from the “best existing device”, such as resolution and repeatability of the unit under calibration, are not included in the CMC uncertainties claim.” 5 The QRPT (RPM, PPC, PM230, PM600) uncertainty budgets are prepared in accordance with Fluke technical note 8050TN11. 6 The Gas – Differential mode uncertainty budgets are prepared in accordance with Fluke technical note 9940TN02. 7 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 8 This scope meets A2LA’s P112 Flexible Scope Policy.
See scope document
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4171.01) Revised 04/09/2026 Page 5 of 5 9 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification.
6ISO/IEC 17025:2017--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.