Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch
No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province, 523942, People's Republic of China, Dongguan City, Guangdong Province, China
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch?
Claim this profile to keep it accurate.
Register record
- A2LARefreshed
- 2951.01Active
Accredited standards
45Our reading of the A2LA scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.
IEC
IEC 60065Name not checked yet
IEC 60950-1; IEC 60065; IEC 62109-1; IEC 62109-2; IEC 62368-1
IEC 60601-1-2Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
IEC 61326-2-3; IEC 61326-2-4; IEC 61326-2-5; IEC 60601-1-2; IEC 61326-1
IEC 60950-1Information technology equipment - Safety - Part 1: General requirements
IEC 60950-1; IEC 60065; IEC 62109-1; IEC 62109-2; IEC 62368-1
IEC 61547Equipment for general lighting purposes - EMC immunity requirementsCertificate says EN 61547. Probably the same standard; not checked against the EN document.
IEC 61000-6-4; IEC 55014-2; IEC 61547; IEC 61851-21-1; IEC 61851-21-2
IEC 61851-21-1Name not checked yet
IEC 61000-6-4; IEC 55014-2; IEC 61547; IEC 61851-21-1; IEC 61851-21-2
IEC 61851-21-2Name not checked yet
IEC 61000-6-4; IEC 55014-2; IEC 61547; IEC 61851-21-1; IEC 61851-21-2
IEC 61960-3Name not checked yet
IEC 62133; IEC 61960; IEC 61960-3; IEC 62620; IEC 62133-1
IEC 62040-2Uninterruptible power systems (UPS) - Part 2: Electromagnetic compatibility (EMC) requirements
IEC 62040-4-2; IEC 62040-2; IEC 62233; IEC 62493; IEC 62311
IEC 62040-4-2Name not checked yet
IEC 62040-4-2; IEC 62040-2; IEC 62233; IEC 62493; IEC 62311
IEC 62109-1Name not checked yet
IEC 60950-1; IEC 60065; IEC 62109-1; IEC 62109-2; IEC 62368-1
IEC 62109-2Name not checked yet
IEC 60950-1; IEC 60065; IEC 62109-1; IEC 62109-2; IEC 62368-1
IEC 62133-1Name not checked yet
IEC 62133; IEC 61960; IEC 61960-3; IEC 62620; IEC 62133-1
IEC 62233Measurement methods for electromagnetic fields of household appliances and similar apparatus with regard to human exposure
IEC 62040-4-2; IEC 62040-2; IEC 62233; IEC 62493; IEC 62311
IEC 62233; IEC 62493; IEC 62311
IEC 62301Name not checked yet
IEC 62087; IEC 62301
IEC 62311Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz to 300 GHz)Certificate says EN 62311. Probably the same standard; not checked against the EN document.
IEC 62040-4-2; IEC 62040-2; IEC 62233; IEC 62493; IEC 62311
IEC 62233; IEC 62493; IEC 62311
IEC 62368-1Audio/video, information and communication technology equipment - Part 1: Safety requirements
IEC 60950-1; IEC 60065; IEC 62109-1; IEC 62109-2; IEC 62368-1
IEC 62493Name not checked yet
IEC 62040-4-2; IEC 62040-2; IEC 62233; IEC 62493; IEC 62311
IEC 62233; IEC 62493; IEC 62311
IEC 62620Name not checked yet
IEC 62133; IEC 61960; IEC 61960-3; IEC 62620; IEC 62133-1
IEC 61000 series
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-2; IEC 61000-3-3; IEC 61000-3-11; ANSI C63
IEC 61000-3-2; IEC 61000-3-3; IEC 61000-3-11; IEC 61000-4-2; IEC 61000-4-3
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-3-2; IEC 61000-3-3; IEC 61000-3-11; ANSI C63
IEC 61000-3-2; IEC 61000-3-3; IEC 61000-3-11; IEC 61000-4-2; IEC 61000-4-3
IEC 61000-3-11Electromagnetic compatibility (EMC) - Part 3-11: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems - Equipment with rated current ≤ 75 A and subject to conditional connection
IEC 61000-3-2; IEC 61000-3-3; IEC 61000-3-11; ANSI C63
IEC 61000-3-2; IEC 61000-3-3; IEC 61000-3-11; IEC 61000-4-2; IEC 61000-4-3
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-6
IEC 61000-3-2; IEC 61000-3-3; IEC 61000-3-11; IEC 61000-4-2; IEC 61000-4-3
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity testCertificate says EN 61000-4-3. Probably the same standard; not checked against the EN document.
IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-6
IEC 61000-3-2; IEC 61000-3-3; IEC 61000-3-11; IEC 61000-4-2; IEC 61000-4-3
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-6
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-6
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-6
IEC 61000-4-6; IEC 61000-4-8; IEC 61000-4-11; IEC 61000-6-1; IEC 61000-6-2
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-6; IEC 61000-4-8; IEC 61000-4-11; IEC 61000-6-1; IEC 61000-6-2
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 61000-4-6; IEC 61000-4-8; IEC 61000-4-11; IEC 61000-6-1; IEC 61000-6-2
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
IEC 61000-4-6; IEC 61000-4-8; IEC 61000-4-11; IEC 61000-6-1; IEC 61000-6-2
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
IEC 61000-4-6; IEC 61000-4-8; IEC 61000-4-11; IEC 61000-6-1; IEC 61000-6-2
IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
IEC 61000-6-4; IEC 55014-2; IEC 61547; IEC 61851-21-1; IEC 61851-21-2
IEC 62087 series
IEC 62087Name not checked yet
IEC 62087; IEC 62301
IEC 62087-1Name not checked yet
IEC 62087-1; IEC 62087-2; IEC 62087-3; IEC 62087-4; IEC 62087-5
IEC 62087-2Name not checked yet
IEC 62087-1; IEC 62087-2; IEC 62087-3; IEC 62087-4; IEC 62087-5
IEC 62087-3Name not checked yet
IEC 62087-1; IEC 62087-2; IEC 62087-3; IEC 62087-4; IEC 62087-5
IEC 62087-4Name not checked yet
IEC 62087-1; IEC 62087-2; IEC 62087-3; IEC 62087-4; IEC 62087-5
IEC 62087-5Name not checked yet
IEC 62087-1; IEC 62087-2; IEC 62087-3; IEC 62087-4; IEC 62087-5
IEC 61326 series
IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
IEC 61326-2-3; IEC 61326-2-4; IEC 61326-2-5; IEC 60601-1-2; IEC 61326-1
IEC 61326-2-3Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-3: Particular requirements - Test configuration, operational conditions and performance criteria for transducers with integrated or remote signal conditioning
IEC 61326-2-3; IEC 61326-2-4; IEC 61326-2-5; IEC 60601-1-2; IEC 61326-1
IEC 61326-2-4Name not checked yet
IEC 61326-2-3; IEC 61326-2-4; IEC 61326-2-5; IEC 60601-1-2; IEC 61326-1
IEC 61326-2-5Name not checked yet
IEC 61326-2-3; IEC 61326-2-4; IEC 61326-2-5; IEC 60601-1-2; IEC 61326-1
CISPR
CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: EmissionCertificate says IEC 55014-1. Probably the same standard; not checked against the EN document.
ISO/IEC 17025:2017; IEC 17025; IEC 55014-1; IEC 55015; ANSI C63
IEC 55014-1; IEC 55015; ANSI C63
CISPR 14-2Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standardCertificate says IEC 55014-2. Probably the same standard; not checked against the EN document.
IEC 61000-6-4; IEC 55014-2; IEC 61547; IEC 61851-21-1; IEC 61851-21-2
CISPR 15Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipmentCertificate says IEC 55015. Probably the same standard; not checked against the EN document.
ISO/IEC 17025:2017; IEC 17025; IEC 55014-1; IEC 55015; ANSI C63
IEC 55014-1; IEC 55015; ANSI C63
Other standards
ANSI C63Name not checked yet
ANSI C63
Scope as published by A2LA
17 lines
ISO/IEC 17025
Active2951.01
The scope document we hold says it was valid until 2026-02-28. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2025-12-02. Check the A2LA register for the current scope.
Labs with overlapping accredited scope in China
- Centre Testing International Group Co.,Shenzhen, GuangdongA2LAShares 4 accredited test methodsANSI C63IEC 55014-1IEC 61000-3-2
- Attestation of Global Compliance (Shenzhen) Co.,GuangdongA2LAShares 3 accredited test methodsANSI C63IEC 61000-3-2IEC 62368-1
- BTF Testing Lab (Shenzhen) Co.,Shenzhen, GuangdongA2LAShares 3 accredited test methodsANSI C63IEC 55014-1IEC 61000-4-2
- BTL Inc. (Dongguan)Dongguan, GuangdongA2LAShares 3 accredited test methodsANSI C63IEC 55014-1IEC 62368-1
- BTL Inc. (Shanghai)ShanghaiA2LAShares 3 accredited test methodsANSI C63IEC 55014-1IEC 61000-4-2
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.