Przedsiębiorstwo Badań i Analiz Energetycznych ENERGOTHERM

ul. Poznańska 5, 62-081, Przeźmierowo, Poland

PCA AB 1624ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
31
PCA certificate
1
Site in our directory
1
PCA accredited scope

What this lab is accredited for

Our reading of the PCA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 31 standard numbers and the 26 official names we hold. When no standard matches, it searches the method text of every scope line.

EN14
EN 1911Stationary source emissions - Determination of mass concentration of gaseous chlorides expressed as HCl - Standard reference method
EN 1948-1Stationary source emissions - Determination of the mass concentration of PCDDs/PCDFs and dioxin-like PCBs - Part 1: Sampling of PCDDs/PCDFs
EN 1948-4
EN 12619Stationary source emissions - Determination of the mass concentration of total gaseous organic carbon - Continuous flame ionisation detector method
EN 13211Air quality - Stationary source emissions - Manual method of determination of the concentration of total mercury
EN 13284-1Stationary source emissions - Determination of low range mass concentration of dust - Part 1: Manual gravimetric method
EN 13649
EN 14181Stationary source emissions - Quality assurance of automated measuring systems
EN 14385Stationary source emissions - Determination of the total emission of As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl and V
EN 14789Stationary source emissions - Determination of volume concentration of oxygen - Standard reference method: Paramagnetism
EN 14790Stationary source emissions - Determination of the water vapour in ducts - Standard reference method
EN 14791Stationary source emissions - Determination of mass concentration of sulphur oxides - Standard reference method
EN 14792Stationary source emissions - Determination of mass concentration of nitrogen oxides - Standard reference method: Chemiluminescence
EN 15058Stationary source emissions - Determination of the mass concentration of carbon monoxide - Standard reference method: non-dispersive infrared spectrometry
ISO13
ISO 3744Acoustics - Determination of sound power levels of noise sources using sound pressure - Engineering methods for an essentially free field over a reflecting plane
ISO 3746Acoustics - Determination of sound power levels and sound energy levels of noise sources using sound pressure - Survey method using an enveloping measurement surface over a reflecting plane
ISO 7935Stationary source emissions - Determination of the mass concentration of sulfur dioxide in flue gases - Performance characteristics of automated measuring systems
ISO 9612Acoustics - Determination of occupational noise exposure - Methodology
ISO 9613-2Acoustics - Attenuation of sound during propagation outdoors - Part 2: Engineering method for the prediction of sound pressure levels outdoors
ISO 10396Stationary source emissions - Sampling for the automated determination of gas emission concentrations for permanently-installed monitoring systems
ISO 10494Turbines and turbine sets - Measurement of emitted airborne noise - Engineering/survey method
ISO 11338-1Stationary source emissions - Determination of gas and particle-phase polycyclic aromatic hydrocarbons - Part 1: Sampling
ISO 12039Stationary source emissions - Determination of the mass concentration of carbon monoxide, carbon dioxide and oxygen in flue gas - Performance characteristics of automated measuring systems
ISO 15713Stationary source emissions - Sampling and determination of gaseous fluoride content
ISO 16911-1Stationary source emissions - Manual and automatic determination of velocity and volume flow rate in ducts - Part 1: Manual reference method
ISO 21258Stationary source emissions - Determination of the mass concentration of dinitrogen monoxide (N2O) - Reference method: Non-dispersive infrared method
ISO 21877Stationary source emissions— Determination of the mass concentration of ammonia - Manual method
Other standards4
DIN 45635-46
DIN 45635-47
PN-N-01307:1994Hałas - Dopuszczalne wartości hałasu w środowisku pracy - Wymagania dotyczące wykonywania pomiarów
PN-Z-04030-7:1994

Read from the PCA scope document we downloaded on 2026-03-13. Register refreshed 2026-11-06.

Scope as published by PCA

8 lines
PCA

ISO/IEC 17025

Active

AB 1624

The scope document we hold says it is valid until 2028-09-14.

View on PCA

Accredited scope, certificate AB 1624

LineMethodMatrixRange
1-waste gases; noise in the workplace; noise at general environment
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

PCA Zakres akredytacji Nr AB 1624 Scope of accreditation No. AB 1624 ZAKRES AKREDYTACJI LABORATORIUM BADAWCZEGO SCOPE OF ACCREDITATION FOR TESTING LABORATORY Nr/No. AB 1624 wydany przez / issued by POLSKIE CENTRUM AKREDYTACJI 01-382 Warszawa, ul. Szczotkarska 42 Wydanie/Issue 15 z/of 24.07.2025 KIEROWNIK DZIAŁU AKREDYTACJI BADAŃ EMISJI W ŚRODOWISKU MARCIN BEKAS Niniejszy dokument jest załącznikiem do Ce rtyfikatu Akredytacji Nr AB 1624 z dnia 18.10.2019 r. Cykl akredytacji od 09.08.2024 r. do 14.09.2028 r. Status akredytacji oraz aktualność zakresu akredytacji można potwierdzić na stronie internetowej PCA www.pca.gov.pl This document is an annex to accreditation certificate No AB 1624 of 18.10.2019 Accreditation cycle from 09.08.2024 to 14.09.2028 The status of accreditation and validity of the scope of accreditation can be confirmed at PCA website www.pca.gov.pl Wydanie nr / Issue No 15, 24.07.2025 r. 1/9 Nazwa i adres / Name and address Przedsiębiorstwo Badań i Analiz Energetycznych ENERGOTHERM Sp. z o.o. LABORATORIUM BADAWCZE ul. Poznańska 5 62 – 081 Przeźmierowo Kod identyfikacyjny / Identification code *) Dziedzina i przedmiot badań / Field of testing and item: - A/13 - C/36/P - Badania akustyczne – maszyny i urządzenia / Acoustic tests of machinery and devices - Badania chemiczne i pobieranie próbek gazów odlotowych / Chemical tests and sampling of waste gases - G/33, G/34, G/36, - M/13, M/58 - Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – gazy odlotowe, hałas w środowisku pracy, hałas w środowisku ogólnym / Tests concerning environmental engineering (environmental and climatic) - waste gases, noise in the workplace, noise at gene ral environment - Badania inne - QAL2 i AST automatycznych systemów monitoringu (AMS) / Other tests - QAL2 and AST of automated measuring systems (AMS) - N/36/P - Badania właściwości fizycznych i pobieranie próbek gazów odlotowych / Tests of physical properties and sampling of waste gases - P/36 - Pobieranie próbek gazów odlotowych / Sampling of waste gases Wersja strony/Page version: A *) Kod identyfikacyjny zgodnie z załącznikiem do dokumentu DAB -07 dostępnym na stronie internetowej www.pca.gov.pl / The identification code according to the Annex to document DAB -07, available at PCA website www.pca.gov.pl AB 1624
-
2PN-EN ISO 16911-1:2013-07; PN-Z-04030-7:1994; PN-EN 13284-1:2018-02; ISO 10396:2007; PN-ISO 7935:2000; PN-EN 14792:2017; ISO 12039:2019; PN-EN 15058:2017; PN-EN 14789:2017Flue gas0.001 to 100 g/m3
3ISO 10396:2007; PN-EN 14790:2017-04; PN-EN 14791:2017-04; PN-EN 1911:2011; ISO 15713:2006; PN-EN 13211:2006; PN-EN 14385:2005Flue gasSee scope document
4PN-EN 12619:2013-05; PN-EN 1948-1:2006; PN-EN 1948-4+A1:2014-03; PN-EN 13649:2005; PN-Z-04030-7:1994; ISO 10396:2007; PN-EN ISO 21877:2020-03; VDI 2462-2:2011; PN-ISO 10396:2001Flue gasSee scope document
5PN-EN 14792:2017; PN-ISO 10396:2001; PN-EN 15058:2017; PN-ISO 10396:2001; PN-EN 14789:2017; PN-ISO 10396:2001; PN-ISO 10396:2001; PN-ISO 10396:2001; PN-EN 14385:2005; PN-EN 1948-4+A1:2014-03; ISO 11338-1:2003; PN-EN ISO 21258:2010; CEN/TS 17340:2020-09Flue gasSee scope document
6VDI 3486 Blatt 2:1979; PN-EN 14181:2015; PN-Z-04030-7:1994; PN-EN 13284-1:2018-02; PN-EN 14791:2017-04; PN-EN 14792:2017; PN-EN 15058:2017; PN-EN 14789:2017; PN-EN 14790:2017-04; PN-EN 12619:2013-05Flue gasSee scope document
7PN-EN 14181:2015; ISO 10396:2007; PN-EN ISO 21258:2010; PN-EN 1911:2011; ISO 15713:2006; CEN/TS 17340:2020-09; PN-EN 13211:2006; PN-EN ISO 21877:2020-03; ISO 12039:2019Automatyczne Systemy Monitoringu (AMS)See scope document
8PN-EN ISO 3746:2011+Ap1:2017-09; PN-EN ISO 3744:2011; DIN 45635-46:1985-06; DIN 45635-47:1985-06; ISO 10494:2018; Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (Dz. U. z 2023 r. poz. 1706); PN ISO 9613-2:2002; PN-N-01307: 1994; PN-EN ISO 9612:2011Maszyny i urządzenia w tym wieże chłodnicze, kominy, turbiny i turbozespołySee scope document

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

ul. Poznańska 5, Przeźmierowo, 62-081, PL

52.42607, 16.78738

Open in Maps

Accreditation data refreshed from the PCA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the PCA entry linked above.