Registers refreshed 2026-11-20.See refresh dates
Japan

Intertek Japan K.K.

Yasuda Shibaura No.2 Bldg. 4F, 3-2-12, Kaigan, Minato-ku, Tokyo, 108-0022, Japan, Tokyo, Japan

Visit website
A2LA 4046.01ISO/IEC 17025Register refreshed 2026-11-20
Part of the Intertek group: 86 sites in our directory.

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
26
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 26 standard numbers and the 11 official names we hold. When no standard matches, it searches the method text of every scope line.

IEC 60601 series17
IEC 60601-1-1
IEC 60601-1-3
IEC 60601-1-4
IEC 60601-1-6
IEC 60601-2-5
IEC 60601-2-18
IEC 60601-2-28Medical electrical equipment - Part 2-28: Particular requirements for the basic safety and essential performance of X-ray tube assemblies for medical diagnosis
IEC 60601-2-33Medical electrical equipment - Part 2-33: Particular requirements for the basic safety and essential performance of magnetic resonance equipment for medical diagnosis
IEC 60601-2-37
IEC 60601-2-38
IEC 60601-2-41
IEC 60601-2-43Medical electrical equipment - Part 2-43: Particular requirements for the basic safety and essential performance of X-ray equipment for interventional procedures
Show all 17
IEC 60601-2-44Medical electrical equipment - Part 2-44: Particular requirements for the basic safety and essential performance of X-ray equipment for computed tomography
IEC 60601-2-46Medical electrical equipment - Part 2-46: Particular requirements for the basic safety and essential performance of operating tables
IEC 60601-2-52
IEC 60601-2-54Medical electrical equipment - Part 2-54: Particular requirements for the basic safety and essential performance of X-ray equipment for radiography and radioscopy
IEC 60601-2-63
IEC6
IEC 60204-1Safety of machinery - Electrical equipment of machines - Part 1: General requirements
IEC 60950-1Information technology equipment - Safety - Part 1: General requirements
IEC 62304
IEC 62366-1
IEC 62368-1Audio/video, information and communication technology equipment - Part 1: Safety requirements
IEC 80601-2-60
IEC 61010 series3
IEC 61010-1Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
IEC 61010-2-081
IEC 61010-2-101Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-101: Particular requirements for in vitro diagnostic (IVD) medical equipment

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.

Scope as published by A2LA

3 lines
A2LA

ISO/IEC 17025

Active

4046.01

The scope document we hold says it was valid until 2026-09-30. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2026-03-14. Check the A2LA register for the current scope.

View scope

Accredited scope, certificate 4046.01

LineMethodMatrixRange
1IEC 61010-1; IEC 61010-1 Edition 3.1 2017-01 CONSOLIDATED VERSION; ANSI UL 61010-1 3rd Ed dated May 12 2012, with revision through July 19 2019; IEC 61010-2-081; IEC 61010-2-101; ANSI AAMI ES60601-1:2005/(R)2012 & A1:2012 C1:2009/(R)2012 & A2:2010/(R)2012 (Cons. Text) [Incl. AMD2:2021]; EN 60601-1; EN 60601-1-6; IEC 60601-1; IEC 60601-1 Edition 3.2 2020-08 CONSOLIDATED VERSION; IEC 60601-1-1; IEC 60601-1-3; IEC 60601-1-3 Edition 2.2 2021-01 CONSOLIDATED VERSION; IEC 60601-1-4; IEC 60601-1-6; IEC 60601-1-6 Edition 3.2 2020-07 CONSOLIDATED VERSION; IEC 60601-2-5; IEC 60601-2-5: Edition 3.0 2009-07; IEC 60601-2-18; EN 60601-2-18; IEC 60601-2-18: Edition 3.0 2009-08; IEC 60601-2-28 (Ed 2, Ed 3); IEC 60601-2-28 Edition 3.0 2017-06--
2IEC 60601-2-33; IEC 60601-2-33 Ed. 3.2 b: 2015; IEC 60601-2-33 Edition 4.0 2022-08; IEC 60601-2-37; IEC 60601-2-37 Edition 2.1 2015; IEC 60601-2-38; IEC 60601-2-41; IEC 60601-2-43; IEC 60601-2-43 Edition 3.0 2022-12; IEC 60601-2-44; IEC 60601-2-44 Edition 3.2: 2016; IEC 60601-2-46; IEC 60601-2-52; IEC 60601-2-52 Edition 1.1 2015-03 CONSOLIDATED VERSION; IEC 60601-2-52 Edition 1.0 2009-12; IEC 60601-2-54; IEC 60601-2-54 Edition 2.0 2022-09; IEC 60601-2-63; IEC 60601-2-63 Edition 1.2 2021-05 CONSOLIDATED VERSION; IEC 62304; IEC 62366; IEC 62366-1; IEC 80601-2-60 Edition 2.0 2019-06; AAMI/CSA 60601-1 ED 3.2; CAN/CSA-C22.2 No. 60601-1:14; JIS T 0601-1; IEC 60950-1; IEC 62368-1; IEC 60204-1; EN 60204-1--
3ISO/IEC 17025:2017; A2LA R256--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Yasuda Shibaura No.2 Bldg. 4F, 3-2-12, Kaigan, Minato-ku, Tokyo, 108-0022, Japan, Tokyo, JP

35.67686, 139.76389

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.