Registers refreshed 2026-11-20.See refresh dates
Poland

LAB-SERWIS Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek Sierociński

ul. Rejtana 23, 42-200, Częstochowa, Poland

Visit website
PCA AB 1004ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
35
PCA certificate
1
Site in our directory
1
PCA accredited scope

What this lab is accredited for

Our reading of the PCA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 35 standard numbers and the 22 official names we hold. When no standard matches, it searches the method text of every scope line.

EN12
EN 1838
EN 1911Stationary source emissions - Determination of mass concentration of gaseous chlorides expressed as HCl - Standard reference method
EN 1948-1Stationary source emissions - Determination of the mass concentration of PCDDs/PCDFs and dioxin-like PCBs - Part 1: Sampling of PCDDs/PCDFs
EN 1948-4
EN 12619Stationary source emissions - Determination of the mass concentration of total gaseous organic carbon - Continuous flame ionisation detector method
EN 13211Air quality - Stationary source emissions - Manual method of determination of the concentration of total mercury
EN 13284-1Stationary source emissions - Determination of low range mass concentration of dust - Part 1: Manual gravimetric method
EN 14253Mechanical vibration - Measurement and evaluation of occupational exposure to whole-body vibration with reference to health - Practical guidance

Certificate says EN 14253+A1:2011. Probably the same standard; not checked against the EN document.

EN 14385Stationary source emissions - Determination of the total emission of As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl and V
EN 14791Stationary source emissions - Determination of mass concentration of sulphur oxides - Standard reference method
EN 14792Stationary source emissions - Determination of mass concentration of nitrogen oxides - Standard reference method: Chemiluminescence
EN 15058Stationary source emissions - Determination of the mass concentration of carbon monoxide - Standard reference method: non-dispersive infrared spectrometry
ISO10
ISO 5349-1Mechanical vibration - Measurement and evaluation of human exposure to hand-transmitted vibration - Part 1: General requirements
ISO 5349-2Mechanical vibration - Measurement and evaluation of human exposure to hand-transmitted vibration - Part 2: Practical guidance for measurement at the workplace
ISO 7243Ergonomics of the thermal environment - Assessment of heat stress using the WBGT (wet bulb globe temperature) index
ISO 7730Ergonomics of the thermal environment - Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria
ISO 9612Acoustics - Determination of occupational noise exposure - Methodology
ISO 10396Stationary source emissions - Sampling for the automated determination of gas emission concentrations for permanently-installed monitoring systems
ISO 11079Ergonomics of the thermal environment - Determination and interpretation of cold stress when using required clothing insulation (IREQ) and local cooling effects
ISO 15713Stationary source emissions - Sampling and determination of gaseous fluoride content
ISO 21877Stationary source emissions— Determination of the mass concentration of ammonia - Manual method
ISO 23210Stationary source emissions - Determination of PM10/PM2,5 mass concentration in flue gas - Measurement at low concentrations by use of impactors
Other standards13
PN-83/E-04040.03
PN-N-01307:1994Hałas - Dopuszczalne wartości hałasu w środowisku pracy - Wymagania dotyczące wykonywania pomiarów
PN-Z-01339
PN-Z-04007-2
PN-Z-04008-4:1999
PN-Z-04008-7:2002
PN-Z-04008-7:2002+Az1:2004
PN-Z-04009-11:2008
PN-Z-04030-7:1994
PN-Z-04045-04
PN-Z-04073-1
PN-Z-04507:2022-05Ochrona czystości powietrza - Oznaczanie frakcji wdychalnej aerozolu na stanowiskach pracy metodą grawimetryczną
PN-Z-04508:2022-05

Read from the PCA scope document we downloaded on 2026-03-13. Register refreshed 2026-11-20.

Scope as published by PCA

13 lines
PCA

ISO/IEC 17025

Active

AB 1004

The scope document we hold says it is valid until 2029-03-04.

View on PCA

Location

ul. Rejtana 23, Częstochowa, 42-200, PL

50.80900, 19.12441

Open in Maps

Accreditation data refreshed from the PCA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the PCA entry linked above.