FindTestingLabs
Registers refreshed 2026-10-18.See refresh dates
Australia

COMPLIANCE ENGINEERING SERVICES

90 Indian Drive, Keysborough, Victoria , 3173, Australia, Keysborough, Victoria, Australia

A2LA|2829.01ISO/IEC 17025Register refreshed 2026-10-09
Certificates
1
Scope items
16
Standards
61
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at COMPLIANCE ENGINEERING SERVICES?

Claim this profile to keep it accurate.

Register record

A2LARefreshed
2829.01Active

Accredited standards

61

Our reading of the A2LA scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.

IEC

IEC 60086-4Name not checked yet
As written on the certificate · Line 14 (A2LA 2829.01)

IEC 60086-4; IEC 62133

IEC 60112Name not checked yet
As written on the certificate · Line 12 (A2LA 2829.01)

IEC 60112; IEC 61851-1; IEC 62752

IEC 60601-1-2Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
As written on the certificate · Line 3 (A2LA 2829.01)

IEC 60601-1-2; IEC 61326-2-6; IEC 61326-1

IEC 60669-2-1Name not checked yet
As written on the certificate · Line 6 (A2LA 2829.01)

IEC 62233; IEC 60669-2-1; IEC 61000-6-1; IEC 61000-6-2; IEC 60335-1

IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
As written on the certificate · Line 3 (A2LA 2829.01)

IEC 60601-1-2; IEC 61326-2-6; IEC 61326-1

IEC 61326-2-6Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-6: Particular requirements - In vitro diagnostic (IVD) medical electrical equipment
As written on the certificate · Line 3 (A2LA 2829.01)

IEC 60601-1-2; IEC 61326-2-6; IEC 61326-1

IEC 61770Name not checked yet
As written on the certificate · Line 13 (A2LA 2829.01)

ISO 2178 or ISO 1463; IEC 61770

IEC 61851-1Name not checked yet
As written on the certificate · Line 12 (A2LA 2829.01)

IEC 60112; IEC 61851-1; IEC 62752

IEC 61851-21-2Name not checked yet
As written on the certificate · Line 2 (A2LA 2829.01)

ISO 16750-2; ISO 13766-1; ISO 13766-2; IEC 61851-21-2; IEC 61000-6-3

IEC 62133Name not checked yet
As written on the certificate · Line 14 (A2LA 2829.01)

IEC 60086-4; IEC 62133

IEC 62233Measurement methods for electromagnetic fields of household appliances and similar apparatus with regard to human exposure
As written on the certificate · Line 6 (A2LA 2829.01)

IEC 62233; IEC 60669-2-1; IEC 61000-6-1; IEC 61000-6-2; IEC 60335-1

IEC 62752Name not checked yet
As written on the certificate · Line 12 (A2LA 2829.01)

IEC 60112; IEC 61851-1; IEC 62752

IEC 66100-4-2Name not checked yetCertificate says IEC 6100-4-2. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 4 (A2LA 2829.01)

IEC 61000-3-2; IEC 61000-3-3; IEC 61000-4-2; IEC 6100-4-2; IEC 61000-4-3

IEC 61000 series

IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
As written on the certificate · Line 4 (A2LA 2829.01)

IEC 61000-3-2; IEC 61000-3-3; IEC 61000-4-2; IEC 6100-4-2; IEC 61000-4-3

IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
As written on the certificate · Line 4 (A2LA 2829.01)

IEC 61000-3-2; IEC 61000-3-3; IEC 61000-4-2; IEC 6100-4-2; IEC 61000-4-3

IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
As written on the certificate · Line 4 (A2LA 2829.01)

IEC 61000-3-2; IEC 61000-3-3; IEC 61000-4-2; IEC 6100-4-2; IEC 61000-4-3

IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity testCertificate says EN 61000-4-3. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 4 (A2LA 2829.01)

IEC 61000-3-2; IEC 61000-3-3; IEC 61000-4-2; IEC 6100-4-2; IEC 61000-4-3

IEC 61000-4-12Electromagnetic Compatibility (EMC) - Part 4-12: Testing and measurement techniques - Ring wave immunity test
As written on the certificate · Line 5 (A2LA 2829.01)

IEC 61000-4-12; IEC 61000-4-13; IEC 61000-4-16; IEC 61000-4-18; IEC 61000-4-29

IEC 61000-4-13Electromagnetic compatibility (EMC) - Part 4-13: Testing and measurement techniques - Harmonics and interharmonics including mains signalling at a.c. power port, low frequency immunity tests
As written on the certificate · Line 5 (A2LA 2829.01)

IEC 61000-4-12; IEC 61000-4-13; IEC 61000-4-16; IEC 61000-4-18; IEC 61000-4-29

IEC 61000-4-16Name not checked yet
As written on the certificate · Line 5 (A2LA 2829.01)

IEC 61000-4-12; IEC 61000-4-13; IEC 61000-4-16; IEC 61000-4-18; IEC 61000-4-29

IEC 61000-4-18Name not checked yet
As written on the certificate · Line 5 (A2LA 2829.01)

IEC 61000-4-12; IEC 61000-4-13; IEC 61000-4-16; IEC 61000-4-18; IEC 61000-4-29

IEC 61000-4-29Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests
As written on the certificate · Line 5 (A2LA 2829.01)

IEC 61000-4-12; IEC 61000-4-13; IEC 61000-4-16; IEC 61000-4-18; IEC 61000-4-29

IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
As written on the certificate · Line 6 (A2LA 2829.01)

IEC 62233; IEC 60669-2-1; IEC 61000-6-1; IEC 61000-6-2; IEC 60335-1

IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
As written on the certificate · Line 6 (A2LA 2829.01)

IEC 62233; IEC 60669-2-1; IEC 61000-6-1; IEC 61000-6-2; IEC 60335-1

IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environmentsCertificate says EN 61000-6-3. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 2 (A2LA 2829.01)

ISO 16750-2; ISO 13766-1; ISO 13766-2; IEC 61851-21-2; IEC 61000-6-3

IEC 60335 series

IEC 60335-1Household and similar electrical appliances - Safety - Part 1: General requirements
As written on the certificate · Line 6 (A2LA 2829.01)

IEC 62233; IEC 60669-2-1; IEC 61000-6-1; IEC 61000-6-2; IEC 60335-1

As written on the certificate · Line 9 (A2LA 2829.01)

IEC 60335-1; IEC 60335-2-8; IEC 60335-2-9; IEC 60335-2-13; IEC 60335-2-15

IEC 60335-2-8Household and similar electrical appliances - Safety - Part 2-8: Particular requirements for shavers, hair clippers and similar appliances
As written on the certificate · Line 9 (A2LA 2829.01)

IEC 60335-1; IEC 60335-2-8; IEC 60335-2-9; IEC 60335-2-13; IEC 60335-2-15

IEC 60335-2-9Household and similar electrical appliances - Safety - Part 2-9: Particular requirements for grills, toasters and similar portable cooking appliances
As written on the certificate · Line 9 (A2LA 2829.01)

IEC 60335-1; IEC 60335-2-8; IEC 60335-2-9; IEC 60335-2-13; IEC 60335-2-15

IEC 60335-2-13Household and similar electrical appliances - Safety - Part 2-13: Particular requirements for deep fat fryers, frying pans and similar appliances
As written on the certificate · Line 9 (A2LA 2829.01)

IEC 60335-1; IEC 60335-2-8; IEC 60335-2-9; IEC 60335-2-13; IEC 60335-2-15

IEC 60335-2-15Name not checked yet
As written on the certificate · Line 9 (A2LA 2829.01)

IEC 60335-1; IEC 60335-2-8; IEC 60335-2-9; IEC 60335-2-13; IEC 60335-2-15

IEC 60335-2-73Name not checked yet
As written on the certificate · Line 10 (A2LA 2829.01)

IEC 60335-2-73; IEC 60335-2-74; IEC 60335-2-80; IEC 60335-2-82; IEC 60335-2-85

IEC 60335-2-74Name not checked yet
As written on the certificate · Line 10 (A2LA 2829.01)

IEC 60335-2-73; IEC 60335-2-74; IEC 60335-2-80; IEC 60335-2-82; IEC 60335-2-85

IEC 60335-2-80Name not checked yet
As written on the certificate · Line 10 (A2LA 2829.01)

IEC 60335-2-73; IEC 60335-2-74; IEC 60335-2-80; IEC 60335-2-82; IEC 60335-2-85

IEC 60335-2-82Name not checked yet
As written on the certificate · Line 10 (A2LA 2829.01)

IEC 60335-2-73; IEC 60335-2-74; IEC 60335-2-80; IEC 60335-2-82; IEC 60335-2-85

IEC 60335-2-85Name not checked yet
As written on the certificate · Line 10 (A2LA 2829.01)

IEC 60335-2-73; IEC 60335-2-74; IEC 60335-2-80; IEC 60335-2-82; IEC 60335-2-85

ISO

ISO 1463Metallic and oxide coatings - Measurement of coating thickness - Microscopical method
As written on the certificate · Line 13 (A2LA 2829.01)

ISO 2178 or ISO 1463; IEC 61770

ISO 2178Non-magnetic coatings on magnetic substrates - Measurement of coating thickness - Magnetic method
As written on the certificate · Line 13 (A2LA 2829.01)

ISO 2178 or ISO 1463; IEC 61770

ISO 4892-2Plastics - Methods of exposure to laboratory light sources - Part 2: Xenon-arc lamps
As written on the certificate · Line 8 (A2LA 2829.01)

ASTM B117; ISO 16750-3 Ingress Protection AS 60529; ISO 20653 UV EN ISO 4892-2:2016; ISO 4892-3:2016; ISO 9227

ISO 4892-3Plastics - Methods of exposure to laboratory light sources - Part 3: Fluorescent UV lamps
As written on the certificate · Line 8 (A2LA 2829.01)

ASTM B117; ISO 16750-3 Ingress Protection AS 60529; ISO 20653 UV EN ISO 4892-2:2016; ISO 4892-3:2016; ISO 9227

ISO 8124-1Safety of toys - Part 1: Safety aspects related to mechanical and physical properties
As written on the certificate · Line 11 (A2LA 2829.01)

ISO 8124-1; IEC 60598-1; IEC 60598-2-1; IEC 60598-2-2; IEC 60598-2-3

ISO 9227Corrosion tests in artificial atmospheres - Salt spray tests
As written on the certificate · Line 8 (A2LA 2829.01)

ASTM B117; ISO 16750-3 Ingress Protection AS 60529; ISO 20653 UV EN ISO 4892-2:2016; ISO 4892-3:2016; ISO 9227

ISO 10605Road vehicles - Test methods for electrical disturbances from electrostatic discharge
As written on the certificate · Line 1 (A2LA 2829.01)

ISO/IEC 17025:2017 COMPLIANCE ENGINEERING SERVICES 90; ISO 10605; ISO 11452-2; ISO 11452-2 TEM Cell RF Immunity ISO 11452-3; ISO 11452-3 Bulk Current Injection RF Immunity ISO 11452-4

ISO 13766-1Earth-moving and building construction machinery - Electromagnetic compatibility (EMC) of machines with internal electrical power supply - Part 1: General EMC requirements under typical electromagnetic environmental conditions
As written on the certificate · Line 2 (A2LA 2829.01)

ISO 16750-2; ISO 13766-1; ISO 13766-2; IEC 61851-21-2; IEC 61000-6-3

ISO 13766-2Earth-moving and building construction machinery - Electromagnetic compatibility (EMC) of machines with internal electrical power supply - Part 2: Additional EMC requirements for functional safety
As written on the certificate · Line 2 (A2LA 2829.01)

ISO 16750-2; ISO 13766-1; ISO 13766-2; IEC 61851-21-2; IEC 61000-6-3

ISO 20653Road vehicles - Degrees of protection (IP code) - Protection of electrical equipment against foreign objects, water and access
As written on the certificate · Line 8 (A2LA 2829.01)

ASTM B117; ISO 16750-3 Ingress Protection AS 60529; ISO 20653 UV EN ISO 4892-2:2016; ISO 4892-3:2016; ISO 9227

IEC 60598 series

IEC 60598-1Luminaires - Part 1: General requirements and tests
As written on the certificate · Line 11 (A2LA 2829.01)

ISO 8124-1; IEC 60598-1; IEC 60598-2-1; IEC 60598-2-2; IEC 60598-2-3

IEC 60598-2-1Name not checked yet
As written on the certificate · Line 11 (A2LA 2829.01)

ISO 8124-1; IEC 60598-1; IEC 60598-2-1; IEC 60598-2-2; IEC 60598-2-3

IEC 60598-2-2Name not checked yet
As written on the certificate · Line 11 (A2LA 2829.01)

ISO 8124-1; IEC 60598-1; IEC 60598-2-1; IEC 60598-2-2; IEC 60598-2-3

IEC 60598-2-3Name not checked yet
As written on the certificate · Line 11 (A2LA 2829.01)

ISO 8124-1; IEC 60598-1; IEC 60598-2-1; IEC 60598-2-2; IEC 60598-2-3

ISO 11451 series

ISO 11451-2Road vehicles - Vehicle test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 2: Off-vehicle radiation sources
As written on the certificate · Line 7 (A2LA 2829.01)

ASTM D257-14; ISO 11451-2; ISO 11451-3; ISO 11451-4; ISO 16750-4

ISO 11451-3Road vehicles - Vehicle test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 3: On-board transmitter simulation
As written on the certificate · Line 7 (A2LA 2829.01)

ASTM D257-14; ISO 11451-2; ISO 11451-3; ISO 11451-4; ISO 16750-4

ISO 11451-4Road vehicles - Vehicle test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 4: Harness excitation methods
As written on the certificate · Line 7 (A2LA 2829.01)

ASTM D257-14; ISO 11451-2; ISO 11451-3; ISO 11451-4; ISO 16750-4

ISO 11452 series

ISO 11452-2Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 2: Absorber-lined shielded enclosure
As written on the certificate · Line 1 (A2LA 2829.01)

ISO/IEC 17025:2017 COMPLIANCE ENGINEERING SERVICES 90; ISO 10605; ISO 11452-2; ISO 11452-2 TEM Cell RF Immunity ISO 11452-3; ISO 11452-3 Bulk Current Injection RF Immunity ISO 11452-4

ISO 11452-3Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 3: Transverse electromagnetic (TEM) cell
As written on the certificate · Line 1 (A2LA 2829.01)

ISO/IEC 17025:2017 COMPLIANCE ENGINEERING SERVICES 90; ISO 10605; ISO 11452-2; ISO 11452-2 TEM Cell RF Immunity ISO 11452-3; ISO 11452-3 Bulk Current Injection RF Immunity ISO 11452-4

ISO 11452-4Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 4: Harness excitation methods
As written on the certificate · Line 1 (A2LA 2829.01)

ISO/IEC 17025:2017 COMPLIANCE ENGINEERING SERVICES 90; ISO 10605; ISO 11452-2; ISO 11452-2 TEM Cell RF Immunity ISO 11452-3; ISO 11452-3 Bulk Current Injection RF Immunity ISO 11452-4

ISO 16750 series

ISO 16750-2Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 2: Electrical loads
As written on the certificate · Line 2 (A2LA 2829.01)

ISO 16750-2; ISO 13766-1; ISO 13766-2; IEC 61851-21-2; IEC 61000-6-3

ISO 16750-3Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 3: Mechanical loads
As written on the certificate · Line 8 (A2LA 2829.01)

ASTM B117; ISO 16750-3 Ingress Protection AS 60529; ISO 20653 UV EN ISO 4892-2:2016; ISO 4892-3:2016; ISO 9227

ISO 16750-4Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 4: Climatic loads
As written on the certificate · Line 7 (A2LA 2829.01)

ASTM D257-14; ISO 11451-2; ISO 11451-3; ISO 11451-4; ISO 16750-4

Other standards

ANSI C63Name not checked yet
As written on the certificate · Line 15 (A2LA 2829.01)

ANSI C63

ASTM B117Standard Practice for Operating Salt Spray (Fog) Apparatus
As written on the certificate · Line 8 (A2LA 2829.01)

ASTM B117; ISO 16750-3 Ingress Protection AS 60529; ISO 20653 UV EN ISO 4892-2:2016; ISO 4892-3:2016; ISO 9227

ASTM D257Name not checked yet
As written on the certificate · Line 7 (A2LA 2829.01)

ASTM D257-14; ISO 11451-2; ISO 11451-3; ISO 11451-4; ISO 16750-4

Scope as published by A2LA

16 lines
A2LA

ISO/IEC 17025

Active

2829.01

The scope document we hold says it was valid until 2026-02-28. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2025-12-02. Check the A2LA register for the current scope.

View scope

Location

90 Indian Drive, Keysborough, Victoria , 3173, Australia, Keysborough, Victoria, AU

-38.00536, 145.16741

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.