DTech Calibration and Tools
16151 Cairnway Dr. Suite 100, 77084, Houston, TX, United States
Visit website- Scope lines
- 5
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 5 scope lines.
A2LA certificate 6012.01 · 5 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6012.01) Revised 08/08/2025 Page 1 of 4
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
DTECH CALIBRATION AND TOOLS
16151 Cairnway Dr. Ste #100
Houston, TX 77084
Cristhian Castilla Phone: 832 696 9525
CALIBRATION
Valid To: April 30, 2027 Certificate Number: 6012.01
In recognition of the successful completion of the A2LA evaluation process, (including an assessment of
the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is
granted to this laboratory to perform the following calibrations
1, 5:
I. Dimensional
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Calipers
Up to 24 in
(770 + 7.7L) µin
ULM machine QP 043
Inside Micrometers
Up to 24 in
(220 + 13L) µin
ULM machine QP 068
Outside Micrometers
Up to 24 in
(100 + 16L) µin
ULM machine QP 039
Indicators
Up to 1 in
86 µin
ULM machine QP 044
Linearity Length3 –
X-Axis, Y-Axis
Movement
Up to 36 in
64 µin
Renishaw laser,
environmental & expansion
material compensator QP 024 | to 24 in |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6012.01) Revised 08/08/2025 Page 2 of 4
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Optical Comparator3 –
Linearity
X-Axis
Y-Axis
Magnification
Up to 12 in
(12 to 24) in
Up to 12 in
10X
20X
50X
(255 + 0.70L) µin
(284 + 0.29L) µin
(223 + 3.70L) µin
0.027 %
0.029 %
0.031 %
Glass ruler QP 029
Ball checker & glass
scale QP 029
Depth Micrometer3
Up to 12 in
(410 + 9.7L) µin
ULM machine QP069
Height Gauge3
Up to 36 in
(690 + 1.2L) µin
Comparison to gage
blocks QP 026
Plain Pin/Plug Gages
Up to 10 in
(71 + 8.0L) µin
ULM machine QP 035
Plain Ring Gages
Up to 12 in
(61 + 14L) µin
ULM machine QP 045
Threaded Plug Gages –
Major Diameter
Pitch Diameter
Up to 6 in
Up to 6 in
(70 + 9.8D) µin
(75 + 10D) µin
ULM & 3-wire method
QP 028
Test Indicator3
Up to 0.150 in
86 µin
ULM machine QP 041
End Rods/Length Standards
Up to 24 in
(74 + 17L) µin
ULM machine QP 038
Granite Surface Plates3
Flatness
Repeat Reading
(12 to 102) in
diagonal
(0.000 02 to 0.002) in
31 µin
31 µin
Leveling system
Repeat-o-meter | to 102 in |
| 3 | - | Hardness test blocks; Stage micrometerShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6012.01) Revised 08/08/2025 Page 3 of 4
II. Mechanical
Parameter/Equipment
Range
CMC2, 4, 6 (±)
Comments
Indirect Verification of
Brinell Hardness Testers
HBW 10/3000
195 HBW
255 HBW
541 HBW
3.2 HBW
5.0 HBW
11 HBW
Hardness test blocks
Optical Verification of
Brinell Microscope –
Microscope General
Up to 5 mm
20 µm
Stage micrometer
Pressure – Measuring
Equipment
(3000 to 30 000) psig
0.033 % + 24 psig
Digital pressure
calibrator
Torque – Measuring
Equipment
(1 to 20) lbf·in
(20 to 100) lbf·in
(1 to 500) lbf·ft
0.13 % + 0.12 lbf·in
0.51 % + 0.023 lbf·in
0.28 % + 1.2 lbf·ft
Torque analyzer
_____________________________
1 This laboratory offers limited commercial calibration and field calibration services.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches
or millimeters, D is the numerical value of the nominal diameter of the device, and percent is percent of
reading unless otherwise noted.
5 This scope meets A2LA’s P112 Flexible Scope Policy. | See scope document |
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6012.01) Revised 08/08/2025 Page 4 of 4
6 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter. | ||
| 5 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.