DTech Calibration and Tools

16151 Cairnway Dr. Suite 100, 77084, Houston, TX, United States

Visit website
A2LA 6012.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
5
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 5 scope lines.

A2LA certificate 6012.01 · 5 lines

LineMethodMatrixRange
1--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6012.01) Revised 08/08/2025 Page 1 of 4 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 DTECH CALIBRATION AND TOOLS 16151 Cairnway Dr. Ste #100 Houston, TX 77084 Cristhian Castilla Phone: 832 696 9525 CALIBRATION Valid To: April 30, 2027 Certificate Number: 6012.01 In recognition of the successful completion of the A2LA evaluation process, (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 5: I. Dimensional Parameter/Equipment Range CMC2, 4 (±) Comments Calipers Up to 24 in (770 + 7.7L) µin ULM machine QP 043 Inside Micrometers Up to 24 in (220 + 13L) µin ULM machine QP 068 Outside Micrometers Up to 24 in (100 + 16L) µin ULM machine QP 039 Indicators Up to 1 in 86 µin ULM machine QP 044 Linearity Length3 – X-Axis, Y-Axis Movement Up to 36 in 64 µin Renishaw laser, environmental & expansion material compensator QP 024
to 24 in
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6012.01) Revised 08/08/2025 Page 2 of 4 Parameter/Equipment Range CMC2, 4 (±) Comments Optical Comparator3 – Linearity X-Axis Y-Axis Magnification Up to 12 in (12 to 24) in Up to 12 in 10X 20X 50X (255 + 0.70L) µin (284 + 0.29L) µin (223 + 3.70L) µin 0.027 % 0.029 % 0.031 % Glass ruler QP 029 Ball checker & glass scale QP 029 Depth Micrometer3 Up to 12 in (410 + 9.7L) µin ULM machine QP069 Height Gauge3 Up to 36 in (690 + 1.2L) µin Comparison to gage blocks QP 026 Plain Pin/Plug Gages Up to 10 in (71 + 8.0L) µin ULM machine QP 035 Plain Ring Gages Up to 12 in (61 + 14L) µin ULM machine QP 045 Threaded Plug Gages – Major Diameter Pitch Diameter Up to 6 in Up to 6 in (70 + 9.8D) µin (75 + 10D) µin ULM & 3-wire method QP 028 Test Indicator3 Up to 0.150 in 86 µin ULM machine QP 041 End Rods/Length Standards Up to 24 in (74 + 17L) µin ULM machine QP 038 Granite Surface Plates3 Flatness Repeat Reading (12 to 102) in diagonal (0.000 02 to 0.002) in 31 µin 31 µin Leveling system Repeat-o-meter
to 102 in
3-Hardness test blocks; Stage micrometer
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6012.01) Revised 08/08/2025 Page 3 of 4 II. Mechanical Parameter/Equipment Range CMC2, 4, 6 (±) Comments Indirect Verification of Brinell Hardness Testers HBW 10/3000 195 HBW 255 HBW 541 HBW 3.2 HBW 5.0 HBW 11 HBW Hardness test blocks Optical Verification of Brinell Microscope – Microscope General Up to 5 mm 20 µm Stage micrometer Pressure – Measuring Equipment (3000 to 30 000) psig 0.033 % + 24 psig Digital pressure calibrator Torque – Measuring Equipment (1 to 20) lbf·in (20 to 100) lbf·in (1 to 500) lbf·ft 0.13 % + 0.12 lbf·in 0.51 % + 0.023 lbf·in 0.28 % + 1.2 lbf·ft Torque analyzer _____________________________ 1 This laboratory offers limited commercial calibration and field calibration services. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches or millimeters, D is the numerical value of the nominal diameter of the device, and percent is percent of reading unless otherwise noted. 5 This scope meets A2LA’s P112 Flexible Scope Policy.
See scope document
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6012.01) Revised 08/08/2025 Page 4 of 4 6 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter.
5ISO/IEC 17025:2017; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.