CET Servizi Ricerca e Sviluppo
Via Pesenti, 8, 38060, Villa Lagarina, Italy
Visit website- Accredited standards
- 10
- ACCREDIA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the ACCREDIA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 10 standard numbers and the 0 official names we hold. When no standard matches, it searches the method text of every scope line.
ASTM C97
ASTM C99
ASTM C170
ASTM C880
EN 1926
EN 1936Exclusion
Limits written next to it
Massa volumica apparente/Apparent density, Porosità aperta/Open porosity (/) UNI EN 1936:2007 - escluso/except
EN 12371
EN 12372
EN 13755
EN 14066
UNI EN 13755:2008; ASTM C97/C97M-25; UNI EN 14066:2013 + UNI EN 12372:2022; UNI EN 12372:2022; UNI EN 1936:2007; ASTM C99/C99M-25; UNI EN 14066:2013 + UNI EN 1936:2007; UNI EN 1926:2007; ASTM C880/C880M-25; UNI EN 12371:2010; ASTM C170/C170M-24
Read from the scope as published by ACCREDIA. Register refreshed 2026-11-20.
Scope as published by ACCREDIA
1 line
ISO/IEC 17025
Active01678
Accredited scope, certificate 01678
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | UNI EN 13755:2008; ASTM C97/C97M-25; UNI EN 14066:2013 + UNI EN 12372:2022; UNI EN 12372:2022; UNI EN 1936:2007; ASTM C99/C99M-25; UNI EN 14066:2013 + UNI EN 1936:2007; UNI EN 1926:2007; ASTM C880/C880M-25; UNI EN 12371:2010; ASTM C170/C170M-24 | Pietre naturali/Natural stones | See scope document |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the ACCREDIA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ACCREDIA entry linked above.