CAIRO AVIATION DEPOT CENTER (CADC) - HELWAN PMEL LABORATORY (PMHL)
Egyptian Air Force, Helwan PMHL Laboratory, Helwan Main Workshop Depot Center, Helwan, 11421, Egypt, Helwan, Egypt
- Scope lines
- 9
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 9 scope lines.
A2LA certificate 2336.02 · 9 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; IEC 17025; ANSI/NCSL Z540-1-1994 | Air | to 1 in |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2336.02) Revised 05/09/2025 Page 2 of 8
II. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC2, 3, 7 (±)
Comments
DC Voltage – Generate
(100 to 220) mV
(0.22 to 2.2) V
(2.2 to 22) V
(22 to 220) V
(200 to 1000) V
10 µV/V
4.7 µV/V
3.9 µV/V
13 µV/V
20 µV/V
Fluke 5700A
DC Current – Generate
(100 to 220) µA
(0.22 to 2.2) mA
(2.2 to 22) mA
(22 to 220) mA
(0.22 to 2.2) A
9 µA/A
8.6 µA/A
13 µA/A
12 µA/A
22 µA/A
Fluke 5700A | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2336.02) Revised 05/09/2025 Page 3 of 8
Parameter/Range
Frequency
CMC2, 3, 7 (±)
Comments
AC Voltage – Generate
Up to 10 mV
(10 to100) mV
100 mV to 1 V
(1 to 10) V
(10 to 100) V
(100 to 1000) V
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(1 to 20) kHz
(20 to 50) kHz
110 µV/V
130 µV/V
160 µV/V
410 µV/V
91 µV/V
91 µV/V
73 µV/V
120 µV/V
140 µV/V
430 µV/V
57 µV/V
59 µV/V
59 µV/V
75 µV/V
220 µV/V
630 µV/V
40 µV/V
18 µV/V
18 µV/V
45 µV/V
80 µV/V
260 µV/V
39 µV/V
25 µV/V
35 µV/V
76 µV/V
210 µV/V
Fluke 5700A | ||
| 4 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2336.02) Revised 05/09/2025 Page 4 of 8
Parameter/Equipment
Range
CMC2, 3, 6 (±)
Comments
DC Current – Measure
(100 to 220) µA
(0.22 to 2.2) mA
(2.2 to 22) mA
(22 to 220) mA
(0.22 to 2.2) A
150 µA/A
75 µA/A
76 µA/A
91 µA/A
190 µA/A
3458A multimeter
Resistance – Generate
(Fixed Points)
10 Ω
100 Ω
1 kΩ
10 kΩ
100 kΩ
1 MΩ
10 MΩ
100 MΩ
18 µΩ/Ω
10 µΩ/Ω
9 µΩ/Ω
10 µΩ/Ω
10 µΩ/Ω
150 µΩ/Ω
43 µΩ/Ω
570 µΩ/Ω
Fluke 5700A
Resistance – Measure
10 Ω
(10 to 100) Ω
(100 to 1000) Ω
(1 to 10) kΩ
(10 to 100) kΩ
(100 to 1000) kΩ
(1 to 10) MΩ
77 µΩ/Ω
48 µΩ/Ω
37 µΩ/Ω
36 µΩ/Ω
39 µΩ/Ω
57 µΩ/Ω
120 µΩ/Ω
3458A Multimeter
DC Voltage – Measure
(100 to 220) mV
(0.22 to 2.2) V
(2.2 to 22) V
(22 to 220) V
(220 to 1000) V
26 µV/V
15 µV/V
15 µV/V
86 µV/V
47 µV/V
3458A multimeter
Parameter/Range
Frequency
CMC2, 3, 6 (±)
Comments
AC Current – Measure
@1 kHz
(100 to 220) µA
(0.22 to 2.2) mA
(2.2 to 22) mA
(22 to 220) mA
0.11 %
0.06 %
0.06 %
0.14 %
3458A multimeter
AC Current – Generate7
@1 kHz
(100 to 220) µA
(0.22 to 2.2) mA
(2.2 to 22) mA
(22 to 220) mA
(0.22 to 2.2) A
60 µA/A
58 µA/A
36 µA/A
37 µA/A
41 µA/A
Fluke 5700A | 100 to 1000 V |
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2336.02) Revised 05/09/2025 Page 5 of 8
Parameter/Range
Frequency
CMC2, 3 (±)
Comments
AC Voltage – Measure
(7 to 22) mV
(22 to 70) mV
(70 to 220) mV
220 mV to 2.2 V
(2.2 to 22) V
(22 to 70) V
(70 to 220) V
(220 to 700) V
100 Hz to 1 kHz
(1 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
100 Hz to 1 kHz
(1 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
100 Hz to 1 kHz
(1 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
100 Hz to 1 kHz
(1 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
100 Hz to 1 kHz
(1 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
100 Hz to 1 kHz
(1 to 10) kHz
(10 to 20) kHz
100 Hz to 1 kHz
100 Hz to 1 kHz
210 µV/V
210 µV/V
210 µV/V
360 µV/V
110 µV/V
110 µV/V
120 µV/V
200 µV/V
56 µV/V
56 µV/V
55 µV/V
94 µV/V
29 µV/V
29 µV/V
29 µV/V
54 µV/V
29 µV/V
29 µV/V
29 µV/V
56 µV/V
39 µV/V
38 µV/V
38 µV/V
38 µV/V
50 µV/V
5790A AC
measurement
standard | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2336.02) Revised 05/09/2025 Page 6 of 8
III. Electrical – RF/Microwave
Parameter/Range
Frequency
CMC2, 6 (±)
Comments
Power Meters –
Power Range:
3 µW
10 µW
30 µW
100 µW
300 µW
1.00 mW
3.00 mW
10.00 mW
100.00 mW
Power Reference Output:
1 mW
10 MHz to 18 GHz
0.32 %
0.32 %
0.32 %
0.32 %
0.32 %
0.32 %
0.32 %
0.32 %
0.32 %
1.2 %
HP 11683A range
calibrator
HP 432B with
GIL360 & DMM
IV. Mechanical
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Pneumatic Pressure –
Measure, Calibration of
Pressure Gauges
(1 to 100) psi
(100 to 2000) psi
(2000 to 10 000) psi
1.2 psi
4.8 psi
12 psi
King Nutronics
3692-A and
3666-10k-1
standard pressure
calibrator
Pneumatic Pressure –
Measure, Calibration of
Pressure Transducers
(1 to 100) psi
(100 to 2000) psi
(2000 to 10 000) psi
0.48 psi
1.6 psi
2.6 psi
King Nutronics
3689-A
Torque – Measure
Calibration of Torque
Wrenches, CW & CCW
(60 to 360) lbf·ft
(360 to 600) lbf·ft
2.4 lbf·ft
5.1 lbf·ft
Versa 600
Torque calibrator
Force – Measure,
Calibration of Load Cells,
Digital Force Gage
(Tension & Compression)
(200 to 2000) lbf
(2000 to 20 000) lbf
(20 000 to 50 000) lbf
3 lbf
22 lbf
25 lbf
Standard load cell | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2336.02) Revised 05/09/2025 Page 7 of 8
V. Thermodynamics
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Temperature –Measuring
Equipment
Temperature Indicators
w/ Probes
(-20 to 100) °C
(100 to 200) °C
(200 to 330) °C
0.28 °C
0.36 °C
0.39 °C
20A temperature
calibrator
VI. Time & Frequency
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Frequency – Measure
Up to 20 MHz
(20 to 500) MHz
0.07 Hz
0.08 Hz
5345A with 5071A
reference
Frequency – Measuring
Equipment
10 MHz
1.5 parts in 1011
5071A
RPM – Measure
(Non-Contact Tachometer)
Up to 100 000 RPM
4.2 RPM
HP 3325B function
generator
Rational Speed –
Measure
Up to 100 000 RPM
4.6 RPM
Standard
tachometer
___________________________________________
1 This laboratory offers commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a
percent or fraction of the reading plus a fixed floor specification. | ||
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2336.02) Revised 05/09/2025 Page 8 of 8
4 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
5 This scope meets A2LA’s P112 Flexible Scope Policy.
6 In the statement of CMC, percentages are percentage of reading, unless otherwise indicated.
7 Both manual and automatic calibration processes are available. | ||
| 9 | ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025; ANSI/NCSL Z540-1-1994 and R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.