Taiwan

EKTRON TEK CO.,

NO.182, LN.380, Tong-AN RD., Tianzhong Township, Changhua County 520 Taiwan R.O.C., Changhua, 520, Republic of China Taiwan, Changhua, Taiwan

A2LA 6553.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
7
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 7 scope lines.

A2LA certificate 6553.01 · 7 lines

LineMethodMatrixRange
1--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 6553.01) 07/09/2025 Page 1 of 6 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 EKTRON TEK CO., LTD. No. 182 Ln. 380, Tong-AN RD. Tianzhong Township, Changhua County 520 Taiwan, R.O.C Joyce Chang Phone: +886 4 8761635 email: info@ektrontek.com CALIBRATION Valid To: June 30, 2027 Certificate Number: 6553.01 In recognition of the successful completion of the A2LA evaluation process, (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 5: I. Dimensional Parameter/Equipment Range CMC2 (±) Comments Length3 – Non-Contact Cross Head/Extensometers Displacement Displacement Gauge Up to 1000 mm Up to 500 mm Up to 1000 mm Up to 1000 mm 0.09 mm 0.29 mm 0.29 mm 0.081 mm Laser interferometer Displacement meter, QS- 54 Laser interferometer, QS- 52
to 1000 mm
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 6553.01) 07/09/2025 Page 2 of 6 II. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 4 (±) Comments Electrical Calibration of Thermometer Indicators – Generate & Measure PT 100 Type K Type T (-70 to 0) °C (0 to 50) °C (50 to 200) °C (200 to 300) °C (-70 to 0) °C (0 to 50) °C (50 to 200) °C (200 to 300) °C (-70 to 0) °C (0 to 50) °C (50 to 200) °C (200 to 300) °C 0.5 °C 0.5 °C 0.5 °C 0.5 °C 0.6 °C 0.6 °C 0.6 °C 0.6 °C 0.67 °C 0.67 °C 0.67 °C 0.67 °C QS-60 III. Mechanical Parameter/Equipment Range CMC2, 4, 6 (±) Comments Force – Measuring Equipment Compression (98.1 to 98.1) N (98.1 to 196.1) N (196.1 to 294.2) N (294.2 to 392.3) N (392.3 to 490.3) N (490.3 to 588.4) N (588.4 to 686.5) N (686.5 to 784.5) N (784.5 to 882.6) N (882.6 to 980.7) N (980.7 to 1961.3) N (1961.3 to 2942.0) N (2942.0 to 3922.7) N (3922.7 to 4903.3) N (4903.3 to 5884.0) N (5884.0 to 6864.7) N (6864.7 to 7845.3) N (7845.3 to 8826.0) N (8826.0 to 9806.7) N 0.50 % 0.30 % 0.17 % 0.13 % 0.11 % 0.12 % 0.12 % 0.099 % 0.092 % 0.18 % 0.099 % 0.068 % 0.053 % 0.052 % 0.047 % 0.042 % 0.039 % 0.035 % 0.035 % QS-44, HBM/C3H3 1 ton load cell
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 6553.01) 07/09/2025 Page 3 of 6 Parameter/Equipment Range CMC2, 4, 6 (±) Comments Force – Measuring Equipment (cont) Compression Tension 9806.7 N (9806.7 to 19 613.3) N (19 613.3 to 29 420.0) N (29 420.0 to 39 226.6) N (39 226.6 to 49 033.3) N (49 033.3 to 58 839.9) N (58 839.9 to 68 646.6) N (68 646.6 to 78 453.2) N (78 453.2 to 88 259.9) N (88 259.9 to 98 066.5) N 49 033 N (49 033 to 98 067) N (98 067 to 147 100) N (147 100 to 196 133) N (196 133 to 245 166) N (245 166 to 294 200) N (294 200 to 343 233) N (343 233 to 392 266) N (392 266 to 441 299) N (441 299 to 490 333) N (98.1 N) Fixed point (98.1 to 196.1) N (196.1 to 294.2) N (294.2 to 392.3) N (392.3 to 490.3) N (490.3 to 588.4) N (588.4 to 686.5) N (686.5 to 784.5) N (784.5 to 882.6) N (882.6 to 980.7) N (980.7 to 1961.3) N (1961.3 to 2942.0) N (2942.0 to 3922.7) N (3922.7 to 4903.3) N (4903.3 to 5884.0) N (5884.0 to 6864.7) N (6864.7 to 7845.3) N (7845.3 to 8826.0) N (8826.0 to 9806.7) N 0.37 % 0.21 % 0.15 % 0.12 % 0.098 % 0.087 % 0.082 % 0.082 % 0.076 % 0.078 % 0.51 % 0.28 % 0.20 % 0.16 % 0.14 % 0.13 % 0.11 % 0.097 % 0.095 % 0.092 % 0.68 % 0.27 % 0.22 % 0.16 % 0.13 % 0.13 % 0.13 % 0.10 % 0.13 % 0.20 % 0.11 % 0.076 % 0.060 % 0.051 % 0.049 % 0.042 % 0.038 % 0.035 % 0.034 % QS-44 HBM/C3H3 10 ton load cell QS-44 HBM/C3H3 50 ton load cell QS-44 HBM/C3H3 1 ton load cell
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 6553.01) 07/09/2025 Page 4 of 6 Parameter/Equipment Range CMC2, 4, 6 (±) Comments Force – Measuring Equipment (cont) Tension 9806.7 N (9806.7 to 19 613.3) N (19 613.3 to 29 420.0) N (29 420.0 to 39 226.6) N (39 226.6 to 49 033.3) N (49 033.3 to 58 839.9) N (58 839.9 to 68 646.6) N (68 646.6 to 78 453.2) N (78 453.2 to 88 259.9) N (88 259.9 to 98 066.5) N 49 033 N (49 033 to 98 067) N (98 067 to 147 100) N (147 100 to 196 133) N (196 133 to 245 166) N (245 166 to 294 200) N (294 200 to 343 233) N (343 233 to 392 266) N (392 266 to 441 299) N (441 299 to 490 333) N 0.45 % 0.20 % 0.16 % 0.12 % 0.090 % 0.089 % 0.082 % 0.071 % 0.073 % 0.068 % 0.51 % 0.26 % 0.18 % 0.14 % 0.13 % 0.11 % 0.095 % 0.086 % 0.085 % 0.085 % QS-44 HBM/C3H3 10 ton load cell QS-44 HBM/C3H3 50 ton load cell Force – Universal Testing Machine3 Compression Tension (9.81 to 98.1) N (98.1 to 980.7) N (980.7 to 9806.7) N (4903.3 to 49 033) N (9806.7 to 98 067) N (49 033 to 490 333) N (9.81 to 98.1) N (98.1 to 980.7) N (980.7 to 9806.7) N (4903.3 to 49 033) N (9806.7 to 98 067) N (49 033 to 490 333) N 0.14 N 1.5 N 6.0 N 51 N 79 N 0.39 kN 0.12 N 0.8 N 7.4 N 50 N 79 N 0.7 kN QS-46 – load cell Speed – Measure3 Up to 1000 mm/min (1000 to 2000) mm/min 0.76 mm/min 4 mm/min Laser interferometer with timer, QS-62
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 6553.01) 07/09/2025 Page 5 of 6 Parameter/Equipment Range CMC2 (±) Comments Torque – Torque Sensor Clockwise/Counter- Clockwise Up to 5 N·m (5 to 9) N·m (9 to 14) N·m (14 to 18) N·m (18 to 23) N·m 0.045 N·m 0.052 N·m 0.052 N·m 0.050 N·m 0.054 N·m QS-50 IV. Thermodynamics Parameter/Equipment Range CMC2 (±) Comments Temperature – Platinum Resistance Thermometer (-70 to 0) °C (0 to 50) °C (50 to 200) °C (200 to 300) °C 0.12 °C 0.12 °C 0.12 °C 0.12 °C QS-56 Temperature – Thermocouple Type K Type T (-70 to 0) °C (0 to 50) °C (50 to 200) °C (200 to 300) °C (-70 to 0) °C (0 to 50) °C (50 to 200) °C (200 to 300) °C 0.12 °C 0.12 °C 0.12 °C 0.12 °C 0.13 °C 0.12 °C 0.12 °C 0.12 °C QS-56, platinum resistance thermometer Temperature – Climate Chambers3 (-70 to 0) °C (0 to 50) °C (50 to 200) °C (200 to 300) °C 2.1 °C 1.2 °C 3 °C 5 °C QS-58 ___________________________________________ 1 This laboratory offers commercial and field calibration services.
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 6553.01) 07/09/2025 Page 6 of 6 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., r esolution, repeatability) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 5 This scope meets A2LA’s P112 Flexible Scope Policy. 6 In the statement of CMC, percentage (%) refers to percent of reading, unless otherwise noted.
7ISO/IEC 17025:2017; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.