CENTRE DE RESSOURCES DES INDUSTRIES DU BOIS CERIBOIS
Rovaltain Nord Parc du 45ème parallèle - 14, rue Brillat Savarin, 26300, CHATEAUNEUF SUR ISERE, France
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at CENTRE DE RESSOURCES DES INDUSTRIES DU BOIS CERIBOIS?
Claim this profile to keep it accurate.
Register record
- COFRACRefreshed
- 1-1970Active
Accredited standards
23Our reading of the COFRAC scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.
EN
EN 947Name not checked yet
NF P 20-501; NF P 20-502; NF EN 14608; NF EN 13115; X NF EN 14351-1; NF EN 12046-1; NF EN 14609; NF P 20-302; NF EN 13049; NF EN 947; NF EN 1192; NF EN 14351-2; NF EN 948; NF EN 12046-2; NF EN 12217; NF EN 16361
EN 948Name not checked yet
NF P 20-501; NF P 20-502; NF EN 14608; NF EN 13115; X NF EN 14351-1; NF EN 12046-1; NF EN 14609; NF P 20-302; NF EN 13049; NF EN 947; NF EN 1192; NF EN 14351-2; NF EN 948; NF EN 12046-2; NF EN 12217; NF EN 16361
EN 1026Name not checked yet
NF EN 1027; NF EN 12208; NF EN 14351-1; NF EN 1026; NF EN 12207; NF EN 12211; NF EN 12210; NF EN 14351-2; NF EN 16361
EN 1027Name not checked yet
NF EN 1027; NF EN 12208; NF EN 14351-1; NF EN 1026; NF EN 12207; NF EN 12211; NF EN 12210; NF EN 14351-2; NF EN 16361
EN 1192Name not checked yet
NF P 20-501; NF P 20-502; NF EN 14608; NF EN 13115; X NF EN 14351-1; NF EN 12046-1; NF EN 14609; NF P 20-302; NF EN 13049; NF EN 947; NF EN 1192; NF EN 14351-2; NF EN 948; NF EN 12046-2; NF EN 12217; NF EN 16361
EN 12046-1Name not checked yet
NF P 20-501; NF P 20-502; NF EN 14608; NF EN 13115; X NF EN 14351-1; NF EN 12046-1; NF EN 14609; NF P 20-302; NF EN 13049; NF EN 947; NF EN 1192; NF EN 14351-2; NF EN 948; NF EN 12046-2; NF EN 12217; NF EN 16361
EN 12046-2Name not checked yet
NF P 20-501; NF P 20-502; NF EN 14608; NF EN 13115; X NF EN 14351-1; NF EN 12046-1; NF EN 14609; NF P 20-302; NF EN 13049; NF EN 947; NF EN 1192; NF EN 14351-2; NF EN 948; NF EN 12046-2; NF EN 12217; NF EN 16361
EN 12207Name not checked yet
NF EN 1027; NF EN 12208; NF EN 14351-1; NF EN 1026; NF EN 12207; NF EN 12211; NF EN 12210; NF EN 14351-2; NF EN 16361
EN 12208Name not checked yet
NF EN 1027; NF EN 12208; NF EN 14351-1; NF EN 1026; NF EN 12207; NF EN 12211; NF EN 12210; NF EN 14351-2; NF EN 16361
EN 12210Name not checked yet
NF EN 1027; NF EN 12208; NF EN 14351-1; NF EN 1026; NF EN 12207; NF EN 12211; NF EN 12210; NF EN 14351-2; NF EN 16361
EN 12211Name not checked yet
NF EN 1027; NF EN 12208; NF EN 14351-1; NF EN 1026; NF EN 12207; NF EN 12211; NF EN 12210; NF EN 14351-2; NF EN 16361
EN 12217Name not checked yet
NF P 20-501; NF P 20-502; NF EN 14608; NF EN 13115; X NF EN 14351-1; NF EN 12046-1; NF EN 14609; NF P 20-302; NF EN 13049; NF EN 947; NF EN 1192; NF EN 14351-2; NF EN 948; NF EN 12046-2; NF EN 12217; NF EN 16361
EN 13049Name not checked yet
NF P 20-501; NF P 20-502; NF EN 14608; NF EN 13115; X NF EN 14351-1; NF EN 12046-1; NF EN 14609; NF P 20-302; NF EN 13049; NF EN 947; NF EN 1192; NF EN 14351-2; NF EN 948; NF EN 12046-2; NF EN 12217; NF EN 16361
EN 13115Name not checked yet
NF P 20-501; NF P 20-502; NF EN 14608; NF EN 13115; X NF EN 14351-1; NF EN 12046-1; NF EN 14609; NF P 20-302; NF EN 13049; NF EN 947; NF EN 1192; NF EN 14351-2; NF EN 948; NF EN 12046-2; NF EN 12217; NF EN 16361
EN 14351-1Name not checked yet
NF EN 1027; NF EN 12208; NF EN 14351-1; NF EN 1026; NF EN 12207; NF EN 12211; NF EN 12210; NF EN 14351-2; NF EN 16361
NF P 20-501; NF P 20-502; NF EN 14608; NF EN 13115; X NF EN 14351-1; NF EN 12046-1; NF EN 14609; NF P 20-302; NF EN 13049; NF EN 947; NF EN 1192; NF EN 14351-2; NF EN 948; NF EN 12046-2; NF EN 12217; NF EN 16361
NF EN ISO 10140-1; NF EN ISO 10140-2; NF EN ISO 10140-4; NF EN ISO 717-1; NF EN 16361; NF EN 14351-1; NF EN 14351-2
EN 14351-2Name not checked yet
NF EN 1027; NF EN 12208; NF EN 14351-1; NF EN 1026; NF EN 12207; NF EN 12211; NF EN 12210; NF EN 14351-2; NF EN 16361
NF P 20-501; NF P 20-502; NF EN 14608; NF EN 13115; X NF EN 14351-1; NF EN 12046-1; NF EN 14609; NF P 20-302; NF EN 13049; NF EN 947; NF EN 1192; NF EN 14351-2; NF EN 948; NF EN 12046-2; NF EN 12217; NF EN 16361
NF EN ISO 10140-1; NF EN ISO 10140-2; NF EN ISO 10140-4; NF EN ISO 717-1; NF EN 16361; NF EN 14351-1; NF EN 14351-2
EN 14608Name not checked yet
NF P 20-501; NF P 20-502; NF EN 14608; NF EN 13115; X NF EN 14351-1; NF EN 12046-1; NF EN 14609; NF P 20-302; NF EN 13049; NF EN 947; NF EN 1192; NF EN 14351-2; NF EN 948; NF EN 12046-2; NF EN 12217; NF EN 16361
EN 14609Name not checked yet
NF P 20-501; NF P 20-502; NF EN 14608; NF EN 13115; X NF EN 14351-1; NF EN 12046-1; NF EN 14609; NF P 20-302; NF EN 13049; NF EN 947; NF EN 1192; NF EN 14351-2; NF EN 948; NF EN 12046-2; NF EN 12217; NF EN 16361
EN 16361Name not checked yet
NF EN 1027; NF EN 12208; NF EN 14351-1; NF EN 1026; NF EN 12207; NF EN 12211; NF EN 12210; NF EN 14351-2; NF EN 16361
NF P 20-501; NF P 20-502; NF EN 14608; NF EN 13115; X NF EN 14351-1; NF EN 12046-1; NF EN 14609; NF P 20-302; NF EN 13049; NF EN 947; NF EN 1192; NF EN 14351-2; NF EN 948; NF EN 12046-2; NF EN 12217; NF EN 16361
NF EN ISO 10140-1; NF EN ISO 10140-2; NF EN ISO 10140-4; NF EN ISO 717-1; NF EN 16361; NF EN 14351-1; NF EN 14351-2
ISO 10140 series
ISO 10140-1Acoustics - Laboratory measurement of sound insulation of building elements - Part 1: Application rules for specific products
NF EN ISO 10140-1; NF EN ISO 10140-2; NF EN ISO 10140-4; NF EN ISO 717-1; NF EN 16361; NF EN 14351-1; NF EN 14351-2
ISO 10140-2Acoustics - Laboratory measurement of sound insulation of building elements - Part 2: Measurement of airborne sound insulation
NF EN ISO 10140-1; NF EN ISO 10140-2; NF EN ISO 10140-4; NF EN ISO 717-1; NF EN 16361; NF EN 14351-1; NF EN 14351-2
ISO 10140-4Acoustics - Laboratory measurement of sound insulation of building elements - Part 4: Measurement procedures and requirements
NF EN ISO 10140-1; NF EN ISO 10140-2; NF EN ISO 10140-4; NF EN ISO 717-1; NF EN 16361; NF EN 14351-1; NF EN 14351-2
Other standards
ISO 717-1Acoustics - Rating of sound insulation in buildings and of building elements - Part 1: Airborne sound insulation
NF EN ISO 10140-1; NF EN ISO 10140-2; NF EN ISO 10140-4; NF EN ISO 717-1; NF EN 16361; NF EN 14351-1; NF EN 14351-2
Scope as published by COFRAC
5 lines
ISO/IEC 17025
Active1-1970
Accredited scope, certificate 1-1970
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | materials | - | BATIMENT ET GENIE CIVIL / ELEMENTS DE CONSTRUCTION - COMPOSANTS DE MAÇONNERIE ET ELEMENTS PREFABRIQUES - ISOLANTS ET ELEMENTS D'ENVELOPPE DU BATIMENT - FENETRES, PORTES ET ENSEMBLES MENUISES; BUILDING AND CIVIL ENGINEERING / CONSTRUCTION COMPONENTS - MASONRY UNITS AND PREFABRICATED KITS - INSULATING PRODUCTS AND BUILDING ENVELOPE ELEMENTS - WINDOWS AND DOORSETS | - |
| 2 | materials | - | produits de construction | - |
| 3 | mechanical | NF EN 1027; NF EN 12208; NF EN 14351-1; NF EN 1026; NF EN 12207; NF EN 12211; NF EN 12210; NF EN 14351-2; NF EN 16361 | Fenêtres et blocs-portes extérieurs pour piétons; Blocs-portes intérieurs pour piétons; Portes motorisées pour piétons | - |
| 4 | mechanical | NF P 20-501; NF P 20-502; NF EN 14608; NF EN 13115; X NF EN 14351-1; NF EN 12046-1; NF EN 14609; NF P 20-302; NF EN 13049; NF EN 947; NF EN 1192; NF EN 14351-2; NF EN 948; NF EN 12046-2; NF EN 12217; NF EN 16361 | Fenêtres; Portes | - |
| 5 | mechanical | NF EN ISO 10140-1; NF EN ISO 10140-2; NF EN ISO 10140-4; NF EN ISO 717-1; NF EN 16361; NF EN 14351-1; NF EN 14351-2 | Fenêtre; Porte-fenêtre; Bloc-porte; Parois pour cloison; Plancher; Toiture; Façade (à l’exclusion des vitrages et petits éléments techniques); Parois doubles parements faisant partie des éléments de construction selon l’annexe A de la norme NF EN ISO 10140-1; Coffres de volets roulants | - |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Rovaltain Nord Parc du 45ème parallèle - 14, rue Brillat Savarin, CHATEAUNEUF SUR ISERE, 26300, FR
45.01484, 4.93914
Open in MapsAccreditation data refreshed from the COFRAC register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the COFRAC entry linked above.