Ross Engineering Corporation

540 Westchester Dr., 95008, Campbell, CA, United States

Visit website
A2LA 2746.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
3
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 3 scope lines.

A2LA certificate 2746.01 · 3 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-See scope document
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2746.01) 08/26/2024 Page 2 of 2 Parameter/Range Frequency CMC2, 3, 4 (±) Comments AC Voltage – Measure (1 to 100) mV (0.1 to 1) V (1 to 10) V (10 to 100) V (100 to 700) V (40 to 100) Hz 0.070 % + 12 µV 0.070 % + 0.12 mV 0.070 % + 1.2 mV 0.070 % + 12 mV 0.066 % + 0.20 V Agilent 3458A AC High Voltage – Generate and Measure (1 to 170) kV RMS 60 Hz 0.092 % Ross VD240 and Agilent 3458A AC Current – Measure (0 to 100) µA (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A (1 to 3) A (45 to 100) Hz 0.071 % + 0.030 µA 0.071 % + 0.20 µA 0.071 % + 2.0 µA 0.072 % + 20 µA 0.10 % + 0.20 mA 0.24 % + 2.4 mA Agilent 3458A Keysight 34461A ____________________________________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 In the statement of CMC percent refers to percent of reading, unless otherwise indicated. 4 The measurands stated are measured using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure the measurand in the ranges indicated. CMC's are expressed as either a specific value that covers the full range or as a fraction/percentage of the reading plus a fixed floor specification. 5 This scope meets A2LA’s P112 Flexible Scope Policy.
3ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.