Ross Engineering Corporation
540 Westchester Dr., 95008, Campbell, CA, United States
Visit website- Scope lines
- 3
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 3 scope lines.
A2LA certificate 2746.01 · 3 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | See scope document |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2746.01) 08/26/2024 Page 2 of 2
Parameter/Range
Frequency
CMC2, 3, 4 (±)
Comments
AC Voltage – Measure
(1 to 100) mV
(0.1 to 1) V
(1 to 10) V
(10 to 100) V
(100 to 700) V
(40 to 100) Hz
0.070 % + 12 µV
0.070 % + 0.12 mV
0.070 % + 1.2 mV
0.070 % + 12 mV
0.066 % + 0.20 V
Agilent 3458A
AC High Voltage – Generate
and Measure
(1 to 170) kV RMS
60 Hz
0.092 %
Ross VD240 and Agilent
3458A
AC Current – Measure
(0 to 100) µA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
(1 to 3) A
(45 to 100) Hz
0.071 % + 0.030 µA
0.071 % + 0.20 µA
0.071 % + 2.0 µA
0.072 % + 20 µA
0.10 % + 0.20 mA
0.24 % + 2.4 mA
Agilent 3458A
Keysight 34461A
____________________________________________
1 This laboratory offers commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 In the statement of CMC percent refers to percent of reading, unless otherwise indicated.
4 The measurands stated are measured using the indicated instrument (see Comments). This capability is
suitable for the calibration of the devices intended to measure the measurand in the ranges indicated.
CMC's are expressed as either a specific value that covers the full range or as a fraction/percentage of the
reading plus a fixed floor specification.
5 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 3 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Pacific Calibration ServiceCampbell, CA · under 1 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Trescal, Inc. - Silicon Valley, CASan Jose, CA · ~7 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- SIMCO Electronics - Silicon ValleySanta Clara, CA · ~8 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- HCT AmericaMilpitas, CA · ~17 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Anritsu AUS, CaliforniaMorgan Hill, CA · ~30 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.