What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 3 scope lines.
A2LA certificate 2083.01 · 3 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2083.01) 11/20/2025 Page 1 of 2
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
VAISALA INC.
3 Van de Graaff Drive
Burlington, MA 01803
Yasamin Younesi Phone: 781 825 7047
CALIBRATION
Valid To: December 31, 2027 Certificate Number: 2083.01
In recognition of the successful co mpletion of the A2LA evaluation process (including an assessment of
the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is
granted to this laboratory to perform the following calibrations
1, 4:
I. Chemical
Parameter/Equipment
Range
CMC
2, 5 (±)
Comments
CO
2 Monitors
0 % CO
2
(0.0167 to 3) % CO
2
(> 3 to 20) % CO
2
0.0014 % CO2
0.0014 % CO
2 + 1.1 %
0.0050 % CO
2 + 1.0 %
CO2 volume fraction
in gas
II. Mechanical
Parameter/Equipment
Range
CMC
2, 3 (±)
Comments
Pressure – Measuring
Equipment
(500 to 1100) hPa
0.066 hPa
Fluke DHI PPC4 | ||
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2083.01) 11/20/2025 Page 2 of 2
III. Thermodynamics
Parameter/Equipment
Range
CMC2, 3 (±)
Comments
Relative Humidity –
Measure
(10 to 30) % RH
(> 30 to 45) % RH
(> 45 to 95) % RH
0 % RH
0.50 % RH
0.60 % RH
0.62 % RH
0.10 % RH
Two pressure humidity
chamber
Thunder Scientific 2500
Vaisala DMT348
dewpoint transmitter
Temperature – Measure
(-80 to 180) °C
(-90 to -80) °C
(-80 to -70) °C
(-70 to -55) °C
(-55 to -40) °C
(-40 to 50) °C
(50 to 90) °C
(0 to 15) °C
(> 15 to 25) °C
(> 25 to 40) °C
0.054 °C
0.090 °C
0.080 °C
0.070 °C
0.060 °C
0.050 °C
0.060 °C
0.34 °C
0.13 °C
0.19 °C
Fluke Hart Scientific 2560
w/5614 or 5615 probe
Fluke Hart Scientific 2560
w/12005 PRT
Thunder Scientific 2500
Dewpoint
(> -60 to -10) °C
(> -60 to 10) °C
(-80 to -60) °C
0.73 °C
0.70 °C
0.90 °C
Thunder Scientific 3900
MBW 373LX
_____________________________________________________
1 This laboratory offers commercial calibration service.
2
Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 The type of instrument or material being calib rated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
4 This scope meets A2LA’s P112 Flexible Scope Policy.
5 In the statement of CMC, percentages are percentages of reading, unless otherwise indicated. | -80 to 180 °C |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
VAISALA INC.
Burlington, MA
for technical competence in the field of
Calibration
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements
for the competence of testing and calibration laboratories. This laboratory also meets the requirements of R205 – Specific
Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical
competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 20th day of November 2025.
__ _____________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 2083.01
Valid to December 31, 2027 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.