EGIS INDUSTRIE ET PROCESS
20 rue Massenet, 38400, SAINT-MARTIN D'HERES, France
- Accredited standards
- 4
- COFRAC certificate
- 1
- Sites in our directory
- 2
What this lab is accredited for
Our reading of the COFRAC scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 4 standard numbers and the 2 official names we hold. When no standard matches, it searches the method text of every scope line.
EN 12469
ISO 14644-1Cleanrooms and associated controlled environments - Part 1: Classification of air cleanliness by particle concentration
ISO 14644-3Cleanrooms and associated controlled environments - Part 3: Test methods
NF S90-351
NF EN ISO 14644-1; NF EN ISO 14644-3; NF EN 12469
NF EN ISO 14644-1; NF EN ISO 14644-3
NF S 90-351
Read from the COFRAC scope document we downloaded on 2026-02-12. Register refreshed 2026-11-06.
Scope as published by COFRAC
7 lines
ISO/IEC 17025
Active1-6388
The scope document we hold says it is valid until 2027-03-31.
Accredited scope, certificate 1-6388
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | NF EN ISO/IEC 17025 | ENVIRONNEMENT / BIOCONTAMINATION; EQUIPEMENTS INDUSTRIELS ET PRODUITS D'INGENIERIE / SALLES PROPRES ET A ENVIRONNEMENT MAITRISE | - |
| 2 | NF EN ISO 14644-1; NF EN ISO 14644-3; NF EN 12469 | Poste de sécurité microbiologique PSM | See scope document |
| 3 | NF EN ISO 14644-1; NF EN ISO 14644-3 | Salles propres et à environnement maîtrisé et apparentés | See scope document |
| 4 | NF S 90-351 | Etablissements de santé – Zones à environnement maitrisé | See scope document |
| 5 | FQI-MOP-O02LAB-074; FQI-MOP-O02LAB-016 | Air | - |
| 6 | FQI-MOP-O02LAB-077; FQI-MOP-O02LAB-015 | Type de surface (plan de travail, sol, équipements) | - |
| 7 | FQI-MOP-O02LAB-015 | Environnement maîtrisé : Etablissement de santé et domaines réglementés associés | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Other Locations
1 other site in this organization
Labs with overlapping accredited scope in France
- TERA-ENVIRONNEMENT (LABORATOIRE DE CROLLES)CROLLES · ~15 kmCOFRACShares 1 accredited materialAir
- CARSO - LABORATOIRE SANTÉ ENVIRONNEMENT HYGIÈNE DE LYON (CARSO - LSEHL)VENISSIEUX · ~90 kmCOFRACShares 1 accredited materialAir
- AMIANTE PRELEVEMENT ENVIRONNEMENTMONTELIMAR · ~105 kmCOFRACShares 1 accredited materialAir
- INSTITUT TECHNIQUE DES GAZ ET DE L'AIR - ITGA - SITE DE SAINT ETIENNESAINT ETIENNE · ~110 kmCOFRACShares 1 accredited materialAir
- AIRTHEMIS SUD ESTVENELLES · ~177 kmCOFRACShares 1 accredited materialAir
Accreditation data refreshed from the COFRAC register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the COFRAC entry linked above.