ADMET, Inc.

51 Morgan Drive, Suite 15, 02062, Norwood, MA, United States

Visit website
A2LA 7128.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
6
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 6 standard numbers and the 1 official name we hold. When no standard matches, it searches the method text of every scope line.

ASTM E4
ASTM E18Standard Test Methods for Rockwell Hardness of Metallic Materials
ASTM E83
ASTM E2309
ASTM E2624
ASTM E2658

Read from the A2LA scope document we downloaded on 2025-12-02. Register refreshed 2026-11-20.

Scope as published by A2LA

5 lines
A2LA

ISO/IEC 17025

Active

7128.01

The scope document we hold says it was valid until 2026-07-31. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2025-12-02. Check the A2LA register for the current scope.

View scope

Accredited scope, certificate 7128.01

LineMethodMatrixRange
1ASTM E83; ASTM E2309; ISO/IEC 17025:2017; IEC 17025-See scope document
2ASTM E4; ASTM E2658; ASTM E2624-See scope document
3ASTM E18test blocks-
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7128.01) 05/06/2024 Page 4 of 4 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be e xpected to be larger than the Calibration and Measurement Capability Uncertainty (CMC) found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equi pment. The usual allowance for the uncertainty introduced by the item being calibrated, (e.g., resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty ach ievable on a customer’s site being larger than the CMC. 4 This scope meets A2LA’s P112 Flexible Scope Policy. 5 The type of instrument or material being calibra ted is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 6 In the statement of CMC, percentage (%) refers to percent of reading, unless otherwise noted.
5ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.