HPR Labs
1002 Clay Ct, 77536, Deer Park, TX, United States
- Scope lines
- 3
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 3 scope lines.
A2LA certificate 6608.01 · 3 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6608.01) 11/17/2025 Page 1 of 2
SCOPE OF ACCREDITATION TO ISO/IEC 17025-2017
HPR LABS
1002 Clay Court
Deer Park, TX 77536
Santino Lopez Phone: 832 439 0119
CALIBRATION
Valid To: January 31, 2028 Certificate Number: 6608.01
In recognition of the successful completion of the A2LA evaluation process (including an assessment of
the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is
granted to this laboratory to perform the following calibrations
1, 3:
I. Mechanical
Parameter/Equipment
Range CMC2, 3 (±) Comments
Pressure Gauges
(1000 to 10 000) PSI
0.3 % of reading
AKO pressure tester
TSD 10KPT
display TSD 6500-3
procedure:6.4.P
Manual Torque
(20 to 250) lbfˑft
(60 to 600) lbfˑft
(200 to 2000) lbfˑft
1 % of reading
1 % of reading
1 % of reading
SnapOn TTC400
procedure:6.4.M
SnapOn TTC 12
procedure:6.4.M
SnapOn TTC14
procedure:6.4.M
Hydraulic Torque
(200 to 20 000) lbfˑft
1 % of reading
AKO system TSD
20011, TSD 2011,
TSD 6500-3
procedure:6.4.H | 1000 to 10000 PSI |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6608.01) 11/17/2025 Page 2 of 2
Parameter/Equipment
Range CMC2 (±) Comments
Pneumatic Torque
(200 to 8000) lbfˑft
2 % of reading
AKO system TSD
20011, TSD 2011,
TSD6500-3
procedure:6.4.PN
Electric Torque Wrenches
(200 to 8000) lbfˑft
1.2 % of reading
AKO system TSD
20011, TSD 2011,
TSD6500-3
procedure:6.4. E
_____________________________________________
1 This laboratory offers commercial calibration.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 This scope meets A2LA’s P112 Flexible Scope Policy. | 200 to 8000 lbfˑft |
| 3 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.