Machinist Tool Repair

6484 Grafton Road, 44280, Valley City, OH, United States

Visit website
A2LA 3673.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
5
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 5 scope lines.

A2LA certificate 3673.01 · 5 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; R205-See scope document
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3673.01) 06/04/2025 Page 2 of 4 Parameter/Equipment Range CMC2, 3 (±) Comments Disks, Plugs, & Pins – XXX-ZZ Z-ZZ (0.05 to 4) in (0.4 to 6) in Up to 4 in (1.0 + 2.0L) µin (3.2 + 6.9L) µin 22 µin Pratt & Whitney Labmaster™ universal, gage blocks Gage blocks, Mikematic bench micrometer Ring Gages (0.04 to 7) in (14 + 2.1L) µin Pratt & Whitney Labmaster™ universal, master ring gage Cal Master Up to 12 in (170 + 9.4L) µin Gage blocks, micro-hite Mic Masters – Survey Trees Depth Up to 12 in Up to 12 in (1.2 + 14L) µin (370 + 2.4L) µin Gage blocks, bench micrometer Micro-hite Bench Micrometer Up to 10 in (1.0 + 6.7L) µin Gage blocks Thread Wires Up to 0.15 in (6.0 + 6.2L) µin LaserScan, master wires Micrometer – Outside Diameter Inside Diameter Depth Up to 12 in (12 to 60) in Up to 60 in Up to 12 in (75 + 4.0L) µin (75 + 5.8L) µin (41 + 2.7L) µin (370 + 2.0L) µin Gage blocks Pratt & Whitney measuring machine, gage block Gage blocks, master step set
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3673.01) 06/04/2025 Page 3 of 4 Parameter/Equipment Range CMC2, 3 (±) Comments Indicators (0.001 to 2) in (2 to 4) in (20 + 5L) µin (27 + 1.5L) µin Bench micrometer Calipers OD ID Depth Up to 60 in Up to 1 in Up to 1 in (750 + 2L) µin 46 µin 47 µin Gage blocks Ring gage Gage blocks Height Gages Up to 48 in (29 + 0.5L) µin Gage blocks Bore Micrometers (0.1 to 4) in (31 + 3.5L) µin Ring gages Dial Bore Gages (0.05 to 24) in (17 + 3.3L) µin Bench micrometer Thread Plug Gages – Major Diameter Pitch Diameter (0.06 to 4) in (0.05 to 4) in (9 + 1.3L) µin (24 + 2.6L) µin Thread wires, Pratt & Whitney standard measuring m achine, gage blocks Adjustable Thread Ring Gages – Minor Diameter (0.3125 to 4) in (33 + 1.7L) µin Thread set plugs, height gage Surface Finish – RA (16.1 to 240) µin 0.015L µin Specimen and master profilometer SV-501
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3673.01) 06/04/2025 Page 4 of 4 II. Mechanical Parameter/Equipment Range CMC2, 3 (±) Comments Torque Wrenches (2 to 10) lbf·in (10 to 100) lbf·in (25 to 300) lbf·in (25 to 250) lbf·ft (100 to 1000) lbf·ft (0.0013 + 0.0011T) lbf·in (0.13 + 0.002T) lbf·in (0.071 + 0.005T) lbf·in (0.43 + 0.003T) lbf·ft (2.7 + 0.002T) lbf·ft Torque & tension tester Durometer – (Types A & D) Indentor Extension & Shape – Spring Calibration – Force: Type A Type D Visual Inspection Only (10 to 90) Duro Units (10 to 90) Duro Units (0.54 + 0.004D) Duro Units (0.71 + 0.0003D) Duro Units Shore durocalibrator _______________________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 In the statement of CMC, D is the durometer unit numerical val ue, T is the applied torque, L is the numerical value of the nominal length of the device measured in inches. 4 This scope meets A2LA’s P112 Flexible Scope Policy.
5ISO/IEC 17025:2017; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.