GOBIO GmbH Institut für Gewässeroekologie und angewandte Biologie
Scheidertalstraße 69 a, 65326, Aarbergen-Kettenbach, Germany
Visit website- Accredited standards
- 17
- DAKKS certificates
- 2
- Site in our directory
- 1
What this lab is accredited for
Our reading of the DAKKS scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 17 standard numbers and the 10 official names we hold. When no standard matches, it searches the method text of every scope line.
ISO8
ISO 5814Water quality - Determination of dissolved oxygen - Electrochemical probe method
ISO 9509Water quality - Toxicity test for assessing the inhibition of nitrification of activated sludge microorganisms
ISO 9888Water quality - Evaluation of ultimate aerobic biodegradability of organic compounds in aqueous medium - Static test (Zahn-Wellens method)
ISO 10523Water quality - Determination of pH
ISO 11348-1Water quality - Determination of the inhibitory effect of water samples on the light emission of Vibrio fischeri (Luminescent bacteria test) - Part 1: Method using freshly prepared bacteria
ISO 11348-2Water quality - Determination of the inhibitory effect of water samples on the light emission of Vibrio fischeri (Luminescent bacteria test) - Part 2: Method using liquid-dried bacteria
ISO 15088Water quality - Determination of the acute toxicity of waste water to zebrafish eggs (Danio rerio)
ISO 15923-1Water quality - Determination of selected parameters by discrete analysis systems - Part 1: Ammonium, nitrate, nitrite, chloride, orthophosphate, sulfate and silicate with photometric detection
DIN6
DIN 38410-M1
DIN 38412-L16
DIN 38412-L30
DIN 38412-L33
DIN 38415-T3
DIN 38416
Other standards3
38404-C 4
EN 1484Water analysis - Guidelines for the determination of total organic carbon (TOC) and dissolved organic carbon (DOC)
EN 27888Water quality - Determination of electrical conductivity
DIN 38415 -T 3; HM -21427 -2; DIN 38410 -M 1; HM -AQEM -007 / 01; DIN EN ISO 10523; DIN EN 27888; DIN EN ISO 5814; DIN 38404 -C 4; DIN EN ISO 15923 -1
DIN EN ISO 9888; DIN 38412 -L 30; DIN 38412 -L 33; DIN EN ISO 9509; DIN EN ISO 11348 -1; DIN EN ISO 11348 -2; DIN EN ISO 15088
DIN EN 1484; DIN EN ISO 15088; DIN EN ISO 11348-1; DIN EN ISO 11348-2; DIN 38410-M 1; DIN 38412-L 16
DIN 38416-L 16: 1985-12; DIN 38412-L 30: 1989-03; DIN 38412-L 33: 1991-03; DIN 38415-T 3: 1996-12
Read from the scope as published by DAKKS. Register refreshed 2026-11-06.
Scope as published by DAKKS
6 lines
ISO/IEC 17025
ActiveD-PL-19369-01-00
Accredited scope, certificate D-PL-19369-01-00
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | DIN EN ISO/IEC 17025:2018; DIN EN ISO 9001; DIN EN ISO/IEC 17011 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
ISO/IEC 17025
ActiveD-PL-19369-01-01
Accredited scope, certificate D-PL-19369-01-01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | DIN EN ISO/IEC 17025:2018 | Wasser (Abwasser, Fließgewässer, Oberflächenwasser, Belebtschlamm); Öko- und Modellökosystemen | - |
| 2 | DIN EN ISO 9888; DIN 38412 -L 30; DIN 38412 -L 33; DIN EN ISO 9509; DIN EN ISO 11348 -1; DIN EN ISO 11348 -2; DIN EN ISO 15088 | Wasser (Abwasser, Fließgewässer, Oberflächenwasser, Belebtschlamm) | - |
| 3 | DIN 38415 -T 3; HM -21427 -2; DIN 38410 -M 1; HM -AQEM -007 / 01; DIN EN ISO 10523; DIN EN 27888; DIN EN ISO 5814; DIN 38404 -C 4; DIN EN ISO 15923 -1 | Wasser; Eluaten und wässrigen Lösungen; Fließgewässern; Abwasser; Oberflächenwasser | - |
| 4 | DIN EN 1484; DIN EN ISO 15088; DIN EN ISO 11348-1; DIN EN ISO 11348-2; DIN 38410-M 1; DIN 38412-L 16 | Wasser | - |
| 5 | DIN 38416-L 16: 1985-12; DIN 38412-L 30: 1989-03; DIN 38412-L 33: 1991-03; DIN 38415-T 3: 1996-12 | Phaeophytin; Daphnientest; Algentest; Umu-Test | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Germany
- SGS INSTITUT FRESENIUSTaunusstein · ~12 kmDAKKSShares 1 accredited test methodEN ISO 9001
- Minz Prüf + TestLimburg an der Lahn · ~16 kmDAKKSShares 1 accredited test methodEN ISO 9001
- Link Engineering CompanyLimburg a. d. Lahn · ~16 kmDAKKSShares 1 accredited test methodEN ISO 9001
- WLV WeinanalytikGeisenheim · ~29 kmDAKKSShares 1 accredited test methodEN ISO 9001
- Kost GmbH & Co KGAspisheim · ~38 kmDAKKSShares 1 accredited test methodEN ISO 9001
Accreditation data refreshed from the DAKKS register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.